Loading...
HomeMy WebLinkAbout1997-09-18 On Site Sewage Treatment Inspection Report► o lr.c CnT<rfOBONO Mimkipal Offices Owner: StTHt Address: 2750 Ketiey Parkway Orono, MN 55356 Mailing Address: P.O. Box 66 Crystal Bay. MN 55323 0066 _ Address: 2801 Fox St. Permit #'s: 8001 Dates: 7/23/85 Contractors: Nldmer Bros. (This is (,^^] an existing system ( ] new construction) . 2 SYSTEM COMPLIANCE (1-3): 1 Code Syste^ iiiits or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. Compliant System: Does not meet all current City standards for new construction, but in most respects appears to be designed, located, and constructed in accordance with previous codes and is functioning properly. ^ Non-Compliant System; System may or may not meet current City standards for design construction, or location, but is failing to properly treat and dispose of the current system with less than three feet of vertical separation between the bottom of the drainfield and the saturated soil level. 3 (The saturated soil level ha saturated soil level has not^been s or [ ] has not been identified at this tisw. If identified, this classification is subject to revision.) the TANK CONDITION (5-9): 8 5 Pumpout not needed at this time. 6 Solids accumulation in tanlcs indicates they should be pumped out this year. ^ System is discharging to the surface. Tem)cs must be pumped out within 48 hours. (J/ Inspection risers missing-tanlcs could not be inspected. If tanlcs have not been pumped out within three years, they should be pumped out and risers installed now. Inspection pipe is located over tan)c baffle-can not measure solids' accvunulation. If tanlcs have not been pumped out within three years, they should be pumped out now. 9 (During the last septic tank Maintenance Punpout the tanks ( ] ware or were not confimed to be watertight by the licensed pushing contractor. If the tanks were not confinaad to be watertight, this classification is subject to revision.) p^INFIELD CONDITION (11-14) ; 11 Drainfield is dry, no surfacing evident. Some evidence of surfacing, not critical yet. Repair is not required at this time. Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector immediately. Repair must be completed within 90 days. Drainfield extent and condition unlcnown. 13 14 POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): low COMMENTS: Date of Inspection mSpptic System Inspector I Note: In the event that this inspection report is used to satisfy the requirements for a transfer of property, this report does not guarantee that an existing system will continue to function properly, but indicates the operation of the system under current conditions. Tdcphonc (612) 473-7357 • FAX 4724)510 I!