Loading...
HomeMy WebLinkAbout1991-06-13 On Site Sewage Treatment Inspection ReportOn the Nortb .Shore of ON -SITE SEWAGE TREATMENT lake ,Minnetonka INSPECTION REPORT POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473.7357 OWNER gyp, C K? ADDRESS z2` ' Z � S� &e _ — PERMIT NO.'S. -5G DATES l-�7 — CONTRACTORS phlbe"'r City Ordinance No. 210 requires that each on -site sewage treatment system in Orono he inspected on a regular basis. The on -site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is EA an existing system ❑ new construction) 1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, j2y located, and constructed generally in accordance with previous codes. System appears to be functioning properly, no major upgrading of the system is required at this time. El3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be. operating adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at this time. El4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ replacement pr ocedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan must be suI7:.iitted for review. Your contractor must obtain a permit before work is started. SYSTEM CONDITION( m Checked items may require your action) Tank inspection indicates: ❑ Pumpout not needed at this time. 7* gSolids accumulation in tanks indicates they should be pump- ed out this year to help prevent future problems. ❑ Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. ❑ System is discharging to surface. Tanks must be pumped within 48 hours to eliminate surface discharge. ❑ Inspection risers missing —tanks could not be inspected. Inspection risers 14" die. pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now, SITE CHARACTERISTICS. Limiting Site Factors ❑ Slope Soil High water table Lot size Lake, wetland, or stream ❑ Drainage COMMENTS A d"-l.S-7i Date of Inspection ❑ Inspection pipe is located directly over tank baffle. (Does not give accurate measurement of solids accumulation.) If tanks have not been pumped out within the last three years, mey should tie pumped out now. Drainfield inspection indicates: ❑ Drainfield is dry, no surfacing evident. ❑ Some evidence of surfacing, not critical yet. ❑ Drainfield is saturated ano visibly discharging untreated effluent to the surface. This condition may require replace- ment or additions to drainfield. Contact the City Inspector immediately. Repairs must be completed within 90 days. 1�DrainfiQ�ld exrw�r L .+�nrditine unknown Potential for System Failure (depends on soil types, water table, and system condition) ❑ Low 16"ediurn ❑ High ❑ System is causing visible surface discharge. 1 11 L . Site Capabilities for Future Expansion ❑ Adequate Fair Poor ❑ Inadequate �Pe��ei r.�CS" wP%�aCS11r?�t1i19 I f, Sy finks �k System Inspector Note. In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy Of the system under current conditions based on the available inlormation. This report must be kept on the premises with system location and pumping records. WHITE COPY / Inspector's File GOLD COPY / Homeowner