HomeMy WebLinkAbout1994-11-10 On Site Sewage Treatment Inspection ReportCITY OF ORONO
Municipal Offices
Post Office Box 66
Crystal gay, NN 55323-0066
0 0
OM-8ITR WMAGE T'RSATi)1311T
IKBPNC'•TIOM WORT
Owner: Address:
Permit is:A/�%�Dates: Contractors:
City ordinance number 100 requires that each on -site sewage treatment system in Orono be inspected on a regular basis.
The on -site sewage treatment system at the above address has been inspected and appears to fall into the category
checked below.
(This is 1>4 an existing system ( ) new construction)
"CODE SYSTEFW-A system rhict, meets all the location, design, and construction standards of the current City
Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input
without discharging any pollutants into ground or surface waters.
"CONFORMING SYSTEM -A system+ which does not meet all the location, design, and construction standards of the
current City Codes but was installed according to the code in effect at the time of installation, and which
is operating satisfactorily by treating and disposing of the entire current sewage input without discharging
any pollutants into ground or surface waters.
"NOM-CONFORMING SYSTEM" -A prohibited system; a system located within a designated 100-year floodplain; any
system which may or guy not meet all the Location, design, and construction standards of the current City
Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand
between the distribution device and the limiting soil characteristics.
(The limitinv soil characteristic [ 1 has or JK4 has not been identified at this time. If the limiting soil
characteristic has not been identified, this classification may be subject to revision.)
Ink inapaetion indicates:
5 IlaiOout not rteedld at this time.
$01 accumulation ire tanks indicates they should be pnwped out this year to help prevent future problems.
Ts�N17� accumulation in tanks is at a critical level. Tanks should be pnwped out as sooas possible.
• system is discharging to the surface. Tanks must be pumped out within <E hours to eln iminate surface discharge
9 Inspection risers missing -tanks could not be inspected. Inspection risers (411 dim. pipe) must be installed in eech
tank at next ptwpout. If tanks have not been pumped out within the last three years, they should be pumped
out now.
10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation)
If tanks have not been pumped out within the last three years, they should be gimped out now.
DRAINFIELD COMDITIOM (11-14): 17
Dreinfield i 1pletion indicates:
Draintield dry, no surfacing evident.
t idence of surfacf
13 ra visibly discharging untreated errluent to the surface. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
14 Drainfield extent and condition unknown.
LIMITING SITE FACTORS (slope.settwks.etc. ):
POTENTIAL FOR SYSTEM FAILURE (deoerds on soils water table etc is
COMMENTS:
Date of Inspection Septic System Inspector
Notes In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of
property, be advised that this report does not guarentre or certify that an r■isting system will continue to function
properly but is merely an opinion of the adequacy of the system under current conditions based an the availsble
nformstion.
This report must be kept on the pranises with the system location and pimping records.
w►NTE COPY Inspectors Foe YELLOW COPY AND wain w