HomeMy WebLinkAbout1988-07-06 On Site Sewage Treatment Inspection ReportOpt Hit, North Shore (if'
Lake Mlimetoftka
ON -SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE SOX 66
1335 S. Brown Rd.
Crystal Say, MN 55323
473-7357
OWNER 1-�P Fe r W!c fear) ADDRESS 1 J _-1-9yielf 41n.1, Z&-I-r(—
PERMIT NO.'S. � 5 DATES 10 ` 2 - CONTRACTORS ��1cI6 YAP r (3ra5
City O►dinanue No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site steerage
treatment system at the above scidrass has been inspected and appears to fall into the category checked below.
IThis is ban existing system L1 new construction)
1 Meets or exeerth current City standards in all respects relating to design, construction, and location. Appears to be operating
properly.
2 Does not meet all current City standards for new construction (1978 Codel but in most respects appears to be designed,
located, and constructed generally in accordance with previuv; codes. Svslam appears to be functioning properly; no major
upgrading of the system is required at this time.
3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replecer rant procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION.( m Checked items may require your action)
Tank inspection indicates:
❑ Pumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should be pump-
ed out this yew to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out n soon as possible.
❑ System is discharging to surface. Tanks mutt be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection risen missing —tanks could not be inspected.
Inspection risen (4" dies. pipel must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three yaars, they should be pumped out now.
Inspection pipe is located directly over tank baffle. f Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the lest three years, they
should be pumped out now.
Draintield inspection indicates:
Drainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and vaibly discharging untreated
effluent to the surface. This condition may require replaca-
mant or additions to drainfield. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
❑ Dr mbeld extent and condition unknown.
SITE CHARACTERISTICS:
Limiting Site Factors Potential for System Failure
Sire r4ajsabdlities for
Cl Siam Idepends on soil types, water
Fu , rExpension
❑ Soil taWkand system condition)
Adequate
❑ High water table g Low
❑ Fair
❑ Lot sire ❑ Medium
❑ Poor
Lake, wetland, or stream ❑ High
❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge.
COMMENTS: &,L' 11i f42Z] +ClF1 } Q/94,1 it il1� r. 114`41' A 1:�_01 s, n�d 1I
S/ llc'-
(" I I
r I�INL. Lvc l,[ f lyljrro. 4r.rrjl
Date of Inspection _. Slptic System Inspeeloy
Note. In the event that this inspection report is used to satisfy the requhements for a mortgage Or other transfer of
propert•;, be advised that
th- -3rt does not guarantee or certify that an existino system will continue to function properly, but is merely an
opine n of the adequacy
ystem under current conditions based on the available information.
'this report must tic, kept on the premises with system location and pumping records.
WHITE COPY / Inspectors Fdc GOLD COPY / Homeowner