Loading...
HomeMy WebLinkAboutCouncil Packet 16-3851 Peter BluthDate Application Received: 07/18/16 Date Application Considered as Complete: 07/28/16 60-Day Review Period Expires: 09/26/16 REQUEST FOR COUNCIL ACTION Date: August 22, 2016 Item No. 10 Department Approval: Administrator Approval: Agenda Section: Name: Melanie Curtis mcc JML Planning Title: Planner Item Description: #16-3851, Peter Bluth, 2413 Carman Street, Variances – Resolution Application Summary: The applicant is requesting a side yard setback variance and a rear yard setback variance to permit a 2nd story addition over the existing detached garage. The garage is a legally non-conforming oversized accessory structure. Additionally, the applicant proposes to construct an addition to the home which would result in a separation of 9 feet from the garage where a 10 foot separation setback is required. Planning Commission Recommendation On August 15th the Planning Commission held a public hearing and reviewed the application including the evidence submitted. Following the public hearing the Commission voted 4 to 0 on a motion to approve the variances contingent upon the owners signing the oversized accessory structure covenants. Planning Staff Recommendation Staff recommends approval. A draft approval resolution has been provided for Council’s consideration which incorporates the OAS covenants. COUNCIL ACTION REQUESTED Council should consider adopting or amending the approval resolution. List of Exhibits: Exhibit A. Survey and Plans Exhibit B. Draft Resolution Exhibit C. PC Action Notice Exhibit D. Draft PC Minutes – 08/15/16 Exhibit E. PC Staff Report – 08/09/16 Exhibit F. PC Exhibits SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-17/5/2016Main Floor Plan, Existing1/4"=1'0" DWW06W06W06W06W06W06W03W03W03W01W01W01W09W09W09W09W09W09W09W09W09W03W03W03W03W03W03W03W03W03UPUPUP3'-2"5'-6"3'-3"3'-3"18'14' Main Floor Plan, ProposedSHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-27/5/20161/4"=1'0" W07W07W07W08W08W08W02W02W02W02W02W02W02W02W02W04W04W04W04W04W04W04W04W04W04W04W047'13'-9"13'-7"15'-9"14'-7"19'-4" WINDOW SCHEDULENUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTIONW01 1640FX 1 1 1640FX 17 1/2 " 47 1/2 " FIXED GLASSW02 2020SC 3 2 2020SC 23 1/2 " 23 1/2 " SNGL CASEMENT-HRW03 2040DH 4 1 2040DH 23 1/2 " 47 1/2 " DOUBLE HUNGW04 2040DH 4 2 2040DH 23 1/2 " 47 1/2 " DOUBLE HUNGW06 2640DH 2 1 2640DH 29 1/2 " 47 1/2 " DOUBLE HUNGW07 3030DH 1 2 3030DH 35 1/2 " 35 1/2 " DOUBLE HUNGW08 3036SC 1 2 3036SC 35 1/2 " 41 1/2 " SNGL CASEMENT-HRW09 3050DH 3 1 3050DH 35 1/2 " 59 1/2 " DOUBLE HUNGSHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-37/5/2016Second Floorplan, Proposed1/4"=1'0"1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-47/5/2016South/ East Elevations, Comparison1/8"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-57/5/2016North/West Elevations, Comparison1/8"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-67/5/2016Exterior PerspectiveN.A. SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-77/5/2016Living Room Cross Section1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-87/5/2016House Cross Section1/4"=1'0" UPUP12'-1"22'-8"SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-97/5/2016Garage Main Floor Plan1/4"=1'0" WINDOW SCHEDULENUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTIONW01 3040DH 3 2 3040DH 35 1/2 " 47 1/2 " DOUBLE HUNGW02 3040SC 2 2 3040SC 35 1/2 " 47 1/2 " SNGL CASEMENT-HRDNDNW01W01W01W01W01W01W01W01W016'-9"6'-9"13'-1"14'-1"72" to top72" to top SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-107/5/2016Garage Second Floor Plan1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-117/5/2016Garage Elevations1/8"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-127/5/2016Garage PerspectiveN.A. SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-137/5/2016Garage Cross Section1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-147/5/2016Garage elevations, Comparison1/8"=1'0" NOTICE OF PLANNING COMMISSION ACTION CITY OF ORONO 2750 Kelley Parkway PO Box 66 Crystal Bay, MN 55323 952.249.4620 ZONING FILE: 16-3851 DATE OF NOTICE: 19 August 2016 TO: Peter & Nell Bluth 2413 Carman St Wayzata, MN 55391 COPIES via email: Peter Bluth TYPE OF REQUEST: Variances DATE OF MEETING: 15 August 2016 The Orono Planning Commission voted on a motion to recommend approval of the variances as requested contingent upon the property owner signing the oversized accessory covenant as noted within the staff memo. VOTE: 4 FOR 0 AGAINST Applicant’s next meeting is tentatively scheduled as: Monday, August 22nd This is a City Council meeting. The meeting begins at 7 PM If you desire certified copies of the official Planning Commission minutes, they are available from the City Clerk after review and approval by the Planning Commission. If you have questions, please contact Melanie Curtis at mcurtis@ci.orono.mn.us or 952.249.4627. Council Exhibit D 3. #16-3851 PETER BLUTH, 2413 CARMAN STREET, VARIANCES, 7:18 P.M. – 7:25 P.M. Peter Bluth, Applicant, was present. Curtis stated the applicant is requesting side and rear setback variances in order to add a second story to the existing non-conforming garage to allow for storage and living space. The garage exceeds 1,000 square feet and is therefore defined as an oversized accessory structure requiring additional setbacks. The applicant also proposes to construct an addition to the home over an existing grade-level deck where a screen porch currently exists which would result in a separation of approximately nine feet from the garage where a 10-foot separation setback is required. The property is a corner lot and by definition Shoreline Drive is defined as the front. The south lot line is the rear, which requires a 30-foot setback from the existing garage. The side setback variance is requested to allow expansion of the second story over the garage 28.4 feet from the side lot line where a 30-foot setback is required. In addition, a variance is requested to allow expansion 11.9 feet from the rear lot line where a 30-foot setback is required. The 10-foot code required separation between buildings is for the purpose of reducing massing and bulk on properties. The existing screen porch structure is ten feet from the nearest garage corner. However, the applicants are proposing to construct the addition in line with the west line of the home, which would result in a 9-foot setback. Staff finds that the nonconforming location of the garage constitutes a practical difficulty with respect to making any improvements or changing the footprint. The proximity of the house to the garage further limits options. The encroachment of a corner of the garage by one foot into the separation distance is minimal and does not appear to be impactful as a full wall encroachment from a crowing standpoint. Planning Staff recommends approval of the variances as requested. Staff would recommend the applicant be requested to enter into the standard Oversized Accessory Structure covenant. The Planning Commission had no questions for Staff. Peter Bluth, Applicant, stated he can answer any questions the Planning Commission may have. Thiesse asked if the applicant understands that the oversized accessory structure cannot have a bathroom and that he will be asked to sign an agreement to that effect. Bluth indicated that is correct. Schoenzeit asked if the current garage has footings. Bluth indicated it is slab on grade. Thiesse stated he cannot attach it to the house but he can go up. Thiesse asked if the screened-in porch is on posts. Bluth indicated it is and that it is a deck with a screened-in sunroom. Thiesse asked how the front line is defined. Curtis indicated it would be the narrower of the two street frontages. Thiesse noted there is no way he would ever be able to construct a driveway in that area. Thiesse asked if anything would change if it was defined otherwise. Curtis stated with respect to the requests he is making today, he would still need to meet the 30-foot setbacks. Chair Thiesse opened the public hearing at 7:23 p.m. There were no public comments regarding this application. Chair Thiesse closed the public hearing at 7:23 p.m. Thiesse noted for discussion purposes that the porch is a clean slate and that it should be in conformance if at all possible. Thiesse asked if the one foot relates to the fire code. Curtis indicated it relates to the massing and that they do meet the fire code required separation. Schwingler stated in his view it is a great addition. Leskinen moved, Schoenzeit seconded, to recommend approval of Application No. 16-3851, Peter Bluth, 2413 Carman Street, granting of side and rear setback variances and a structure-to- structure setback variance, subject to Staff recommendations. VOTE: Ayes 4, Nays 0. Date Application Received: 07/18/16 Date Application Considered as Complete: 07/28/16 60-Day Review Period Expires: 09/26/16 To: Chair Thiesse and Planning Commission Members Jessica Loftus, City Administrator From: Melanie Curtis, Planner mcc Date: 9 August 2016 Subject: #16-3851, Peter Bluth, 2413 Carman Street Variances Public Hearing List of Exhibits Exhibit A. Application Exhibit B. Practical Difficulties Documentation Form Exhibit C. Proposed Survey/Site Plan Exhibit D. Proposed Plans and Elevations Exhibit E. Submitted Hardcover Calculations Exhibit F. Applicable Code Sections Exhibit G. Site Photo Exhibit H. Aerial Photos Exhibit I. Public Comments Exhibit J. Property Owners List Exhibit K. Plat Map Background The applicant is requesting a side yard setback and a rear yard setback to permit an expansion upward of the existing 1,014 square foot garage which based on the size and existing setbacks is a non-conforming oversized accessory structure (OAS). Additionally, the applicant proposes to construct an addition to the home over an existing grade-level deck where a screen porch currently exists which would result in a separation of approximately 9 feet from the garage where a 10 foot separation setback is required. Application Summary: The applicant is requesting side and rear setback variances in order to add a second story to the existing non-conforming garage, and a structure-to-structure setback variance in order to construct an addition to the house less than 10 feet from the garage. Staff Recommendation: Planning Department Staff recommends approval. FILE # 16-3851 9 Aug 2016 Page 2 of 5 LOT ANALYSIS WORKSHEET Sections 78-350, 78-1434, 78-1435, 78-1438, & 78-1439 - Setbacks: LR-1C Required Existing Proposed Variance Needed? Front (Shoreline Dr) House = 30’ OAS = 30’ House=49.7’ OAS=102’ House=49.7’ OAS=102’ No Rear (south) House = 30’ OAS = 30’ House=65’ OAS=11.9’ House=54.2’ OAS=11.9’ Yes, OAS Side Street (Carman St) House = 15’ OAS= 30’ House=45.2’ OAS=84’ House=45.2’ OAS=84’ No West Side House= 30’ OAS= 30’ House=65’ OAS=28.4’ House=65’ OAS=28.4’ Yes, OAS Separation between House and OAS 10’ separation House/porch & OAS = 10’ separation New Addition= 9’ Yes Section 78-350 - Lot Area/Width: LR-1C Lot Area Lot Width Required 21,780 s.f. (0.5 acres) 100’’ Actual 21,149 s.f. (0.48 acre) 140’ Section 78-1403- Structural Coverage: Total Lot Area Total Structural Coverage 21,149 s.f. (0.48 acre) Allowed: 3,172 s.f. (15%) Existing: 2,171 s.f. (10%) Proposed: 2,267 s.f. (10.7%) Section 78-1680 and 78-1700 -Hardcover Calculations: Stormwater Overlay District Tier Total Area in Zone Allowed Hardcover Existing Hardcover Proposed Hardcover Tier 2 21,149 s.f. 6,344 s.f. (30 %) 4,708 s.f. (22.6%) 4,972 s.f. (23.5%) FILE # 16-3851 9 Aug 2016 Page 3 of 5 Applicable Regulations: Rear and Side Yard Setback Variances (Code Section 78-1434) The property is a corner lot. By definition, as the short side, Shoreline Drive is considered the “front” yard for setback purposes; the south lot line is the rear. The garage exceeds 1,000 square feet and is therefore defined as an oversized accessory structure (OAS) requiring additional setbacks. The property owner would like to construct a second story over the OAS, an upward expansion, to allow for storage and living space on the second level. Because the OAS does not meet the required 30-foot setbacks from all property lines, variances are required. A side setback variance is requested to allow expansion of the second story 28.4’ from the side lot line where a 30-foot setback is required; additionally a variance is requested to allow expansion 11.9’ from the rear lot line where a 30-foot setback is required. Building to Building Separation Variance (Code Section 78-1438) The code requires a 10-foot separation between buildings to reduce the appearance of massing. The existing screen porch structure is 10 feet from the nearest garage corner, however the property owner proposes to construct the addition in line with the foundation of the west side of the house to the extent of the existing deck. This results in a one foot encroachment into the 10’ separation requirement from corner to corner. Governing Regulation: Variance (Section 78-123) In reviewing applications for variance, the Planning Commission shall consider the effect of the proposed variance upon the health, safety and welfare of the community, existing and anticipated traffic conditions, light and air, danger of fire, risk to the public safety, and the effect on values of property in the surrounding area. The Planning Commission shall consider recommending approval for variances from the literal provisions of the Zoning Code in instances where their strict enforcement would cause practical difficulties because of circumstances unique to the individual property under consideration, and shall recommend approval only when it is demonstrated that such actions will be in keeping with the spirit and intent of the Orono Zoning Code. Economic considerations alone do not constitute practical difficulties. Practical difficulties also include but are not limited to inadequate access to direct sunlight for solar energy systems. Variances shall be granted for earth-sheltered construction as defined in Minn. Stat. § 216C.06, subd. 2, when in harmony with this chapter. The board or the council may not permit as a variance any use that is not permitted under this chapter for property in the zone where the affected person's land is located. The board or council may permit as a variance the temporary use of a one-family dwelling as a two-family dwelling. According to MN §462.537 Subd. 6(2) variances shall only be permitted when: 1. The variance is in harmony with the general intent and purpose of the Ordinance. The proposed addition and second story on the garage are residential in nature. There is adequate space for light air and open space between the proposed addition and garage; the proposed second story addition will not further encroach into the rear or side setbacks. The variances are in harmony with the Ordinance. 2. The variance is consistent with the comprehensive plan. The variances resulting in a permit for construction of improvements to a single family residence and residential garage in a residential zone are consistent with the Comprehensive Plan. 3. The applicant establishes that there are practical difficulties. FILE # 16-3851 9 Aug 2016 Page 4 of 5 a. The property owner proposes to use the property in a reasonable manner not permitted by the official controls; The request to permit construction of additions to the existing garage, an oversized accessory structure, within the 30 foot side and rear setback areas appears to be reasonable as the adjacent properties do not appear to be adversely impacted; the mature vegetation and topography separate the Property from the adjacent neighbors. The proposed setback between the house and the garage at 9 feet is a corner -to-corner measurement. The encroachment will not create an unreasonable perception of additional massing. b. There are circumstances unique to the property not created by the landowner; The size of the garage, and the size and orientation property were not the result of actions by the landowner. The neighboring home is set back sufficiently to allow for light, air, and open space between the garage and the home; and c. The variance will not alter the essential character of the locality. The proposed additions to the garage and home will not alter the character of the neighborhood. The existing home plus detached garage to be expanded are set back sufficiently from Carman Street and it does not appear that a second story addition on the existing garage will adversely impact the neighbor to the south who has provided supportive comments. The structures on adjacent lots are set back 62 feet for the home and 27 feet for the detached garage to the north; and the home to the south is over 84 feet from the property line. Additionally City Code 78-123 provides additional parameters within which a variance may be granted as follows: 4. The special conditions applying to the structure or land in question are peculiar to such property or immediately adjoining property. The applicant’s home is a corner lot with a defined front yard on Shoreline Drive with the functional front facing Carman Street. The garage, constructed in 1975, is in a nonconforming location on the property. The proposed improvements to the garage will not increase the nonconformity. 5. The conditions do not apply generally to other land or structures in the district in which the land is located. The nonconforming location of the garage and the corner lot status make this property unique in the neighborhood. 6. The granting of the application is necessary for the preservation and enjoyment of a substantial property right of the applicant. Staff finds this criterion to be met. 7. The granting of the proposed variance will not in any way impair health, safety, comfort or morals, or in any other respect be contrary to the intent of this chapter. Granting the requested variances will not adversely impact health, safety, comfort, or morals; nor will it be contrary to the intent of the Code. 8. The granting of such variance will not merely serve as a convenience to the applicant, but is necessary to alleviate demonstrable difficulty. The location and size of the garage as well as the garage’s proximity to the home create practical difficulties affecting the Property; the variances are necessary and not merely serve as a convenience to the Owner. The Commission may recommend or Council may impose conditions in granting of variances. Any conditions imposed must be directly related to and must bear a rough proportionality to the impact created by the variance. No variance shall be granted or changed beyond the use permitted in this chapter in the district where such land is located. FILE # 16-3851 9 Aug 2016 Page 5 of 5 Septic System Status The property is served by city sewer. Practical Difficulties Statement Applicant has completed the Practical Difficulties Documentation Form attached as Exhibit B, and should be asked for additional testimony regarding the application. Practical Difficulties Analysis Staff finds that the nonconforming location of the garage constitutes a practical difficulty with respect to making any improvements or changing the footprint. The proximity of the house to the garage further limits options. The encroachment of a corner of the garage by one foot into the separation distance is minimal and does not appear to be impactful as a full wall encroachment from a crowding standpoint. Public Comments The public comments received are included as Exhibit I. Issues for Consideration 1. Does the Planning Commission find that that the property owner proposes to use the property in a reasonable manner which is not permitted by an official control? 2. Does the Planning Commission find that the variance (s), if granted, will not alter the essential character of the neighborhood? 3. Does the Commission find it necessary to impose conditions in order to mitigate the impacts created by the granting of the requested variance(s)? 4. Are there any other issues or concerns with this application? Planning Staff Recommendation The Planning Commission recommends approval of the variances as requested. Staff would also suggest the applicant be requested to enter into the OAS covenant which states: 1. No future subdivision will be approved that places the structure within a lot that has no principal structure, except that the city in its subdivision approval may grant a finite time period in which the oversized accessory structure may remain without a principal structure, in order that a principal structure may be constructed. At the end of this time period, the oversized accessory structure must be removed if no principal structure has been constructed. 2. If the property is subdivided, the oversize accessory structure and principal structure will be located together within a lot that meets the minimum lot area requirement for the given size of accessory building. 3. In subdivision approval, the setback required for the oversize accessory structure shall remain. Such covenant shall be binding on current and future property owners and shall be filed in the chain of title of the property. SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-17/5/2016Main Floor Plan, Existing1/4"=1'0" DWW06W06W06W06W06W06W03W03W03W01W01W01W09W09W09W09W09W09W09W09W09W03W03W03W03W03W03W03W03W03UPUPUP3'-2"5'-6"3'-3"3'-3"18'14' Main Floor Plan, ProposedSHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-27/5/20161/4"=1'0" W07W07W07W08W08W08W02W02W02W02W02W02W02W02W02W04W04W04W04W04W04W04W04W04W04W04W047'13'-9"13'-7"15'-9"14'-7"19'-4" WINDOW SCHEDULENUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTIONW01 1640FX 1 1 1640FX 17 1/2 " 47 1/2 " FIXED GLASSW02 2020SC 3 2 2020SC 23 1/2 " 23 1/2 " SNGL CASEMENT-HRW03 2040DH 4 1 2040DH 23 1/2 " 47 1/2 " DOUBLE HUNGW04 2040DH 4 2 2040DH 23 1/2 " 47 1/2 " DOUBLE HUNGW06 2640DH 2 1 2640DH 29 1/2 " 47 1/2 " DOUBLE HUNGW07 3030DH 1 2 3030DH 35 1/2 " 35 1/2 " DOUBLE HUNGW08 3036SC 1 2 3036SC 35 1/2 " 41 1/2 " SNGL CASEMENT-HRW09 3050DH 3 1 3050DH 35 1/2 " 59 1/2 " DOUBLE HUNGSHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-37/5/2016Second Floorplan, Proposed1/4"=1'0"1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-47/5/2016South/ East Elevations, Comparison1/8"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-57/5/2016North/West Elevations, Comparison1/8"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-67/5/2016Exterior PerspectiveN.A. SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-77/5/2016Living Room Cross Section1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-87/5/2016House Cross Section1/4"=1'0" UPUP12'-1"22'-8"SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-97/5/2016Garage Main Floor Plan1/4"=1'0" WINDOW SCHEDULENUMBER LABEL QTY FLOOR SIZE WIDTH HEIGHT DESCRIPTIONW01 3040DH 3 2 3040DH 35 1/2 " 47 1/2 " DOUBLE HUNGW02 3040SC 2 2 3040SC 35 1/2 " 47 1/2 " SNGL CASEMENT-HRDNDNW01W01W01W01W01W01W01W01W016'-9"6'-9"13'-1"14'-1"72" to top72" to top SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-107/5/2016Garage Second Floor Plan1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-117/5/2016Garage Elevations1/8"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-127/5/2016Garage PerspectiveN.A. SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-137/5/2016Garage Cross Section1/4"=1'0" SHEET:PROJECT DESCRIPTION: DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, Bluth Residence2413 Carman StOrono, MN 55391, -DATE:SHEET TITLE:A-147/5/2016Garage elevations, Comparison1/8"=1'0" Page 1 PC Exhibit F Sec. 78-350. - Area, height, lot width and yard requirements. (a) Height. No structure or building in the LR-1C district shall exceed 2½ stories and shall not exceed 30 feet in height except as provided in section 78-1366. _____ (b) Lots. The following minimum requirements shall be observed: Lot Area (acre) Lot Width (feet) Front Yard (feet) Side Yard (feet) Rear Yard (feet) Side Yard Adjacent to Street (feet) 0.5 100 30 10 30 15 (Code 1984, § 10.25(6); Ord. No. 18 3rd series, § 3, 9-27-2004) _____ Sec. 78-1434. - Area restrictions. In all R districts, no accessory building shall exceed 1,000 square feet of footprint area; except that accessory structures in excess of 1,000 square feet will be allowed under the following conditions: (1) Not more than one oversized accessory structure (OAS) shall be permitted on any property. An oversized accessory structure is defined as an accessory structure of footprint area in excess of 1,000 square feet, except that the following nonroofed accessory structures which exceed 1,000 square feet footprint area are not considered as oversize accessory structures, but are subject to the special setback restrictions of section 78-1404. a. Tennis courts and sport courts. b. Pools, when pool basin structure (excluding nonencroachment-type patios) is greater than 1,000 square feet. c. Paddocks or arenas. (2) Oversized accessory structures are regulated by the following table: Lot Area (acres) Maximum Individual Accessory Structure Maximum Allowed Total of All Accessory Structure Footprint Page 2 Footprint Area (square feet) Areas* on a Property (square feet) 0—1.99 1,000 2,000 2.00—3.00 1,200 2,400 3.01—3.50 1,400 2,800 3.51—4.00 1,600 3,200 4.01—4.50 1,800 3,600 4.51—5.00 2,000 4,000 5.01—6.00 2,200 4,400 6.01—7.00 2,400 4,800 7.01—8.00 2,600 5,200 8.01—9.00 2,800 5,600 9.01 or more 3,000 6,000 * Excluding nonroofed tennis courts, sport courts, pools, paddocks, arenas. (3) Any oversize accessory structure shall be subject to the following conditions: a. No such accessory structure shall be located within a required yard area (principal structure setbacks must be met). Further, no such structure shall be nearer the front lot line than the front line of the principal residence on the property, and no such accessory structure shall be located less than 30 feet from the side or rear lot line regardless whether less strict principal structure setbacks apply. b. The maximum height for such accessory structure shall be 30 feet or the defined height of the principal residence structure on the property, whichever is less. c. Such structure shall be allowed only when the property owner agrees and covenants in writing with the city as follows: 1. No future subdivision will be approved that places the structure within a lot that has no principal structure, except that the city in its subdivision approval may grant a finite time Page 3 period in which the oversized accessory structure may remain without a principal structure, in order that a principal structure may be constructed. At the end of this time period, the oversized accessory structure must be removed if no principal structure has been constructed. 2. If the property is subdivided, the oversize accessory structure and principal structure will be located together within a lot that meets the minimum lot area requirement for the given size of accessory building. 3. In subdivision approval, the setback required for the oversize accessory structure shall remain. Such covenant shall be binding on current and future property owners and shall be filed in the chain of title of the property. (Code 1984, § 10.03(9)(C); Ord. No. 106 3rd series, § 24, 6-10-2013) Sec. 78-1435. - Location. Except as may be specifically provided, no detached garage or other accessory building shall be located nearer to the front or street lot line than the principal building on that lot. Detached garages or other accessory buildings on lots which have frontage on a lake may be located between the rear yards of such lots and the principal building only if setback requirements of section 78 -305(b), section 78-330(b) and section 78-350(b) are met. Exception: Detached garages on lots that have frontage on a lake may be located ten feet from the street or rear lot line when doors face away from the street and an adequate vehicle turnaround is provided on the site. This section shall not apply to lakeshore lots that are divided by streets or private roads or are corner lots. (Code 1984, § 10.03(9)(D); Ord. No. 52 3rd series, § 2, 11-24-2008; Ord. No. 106 3rd series, § 25, 6-10-2013) Sec. 78-1436. - Setbacks. Accessory structures in excess of 750 square feet footprint area but not exceeding 1,000 square feet footprint area shall be located at least 15 feet from any lot line. (Code 1984, § 10.03(9)(E)) Sec. 78-1438. - Crowding principal building. No accessory building, unless an integral part of the principal building, shall be erected, altered or moved within ten feet of the principal building, nor within ten feet of another accessory building. (Code 1984, § 10.03(12); Ord. No. 165 3rd series, § 1, 3-14-2016) Sec. 78-1439. - Garages. Accessory buildings which are for the storage of automobiles shall have the doors 30 fee t or more from the property line when the doors face on a public alley or street. (Code 1984, § 10.03(13)) Aerial View 2015 Pictometry Subject Property Oblique facing north Oblique facing East