Loading...
HomeMy WebLinkAbout1194-11-17 On Site Sewage Treatment Inspection Report-MainCITY OF ORONO Municipal Offices Post Office Box 66 Crystal Bay, MN 55323-0066 \ 7,kESKo¢ ON -SITE SENAdE TREATMENT INSPECTION REPORT Owner: << �. Address: Permit Us:Dates: � �` — Contractors: V ill) V',_ City ordinance rKm 100 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage treatment system at the above address has been inspected and appears to fall into the category checked below. (This is (* an existing system I I new construction) "CODE SYSTEM" -A system which meets all the location, design, and construction standards of the current City Codes, and which is operating satisiactorily by treating and disposing of the entire current sewage input without discharging any pollutants into ground or surface waters. "CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction standards of the current City Codes, but was installed according to the code in effect at the time of installation, and which is operating satisfactorily by tre-ting and disposing of the entire current sewage input without discharging any pollutants into ground or surface water,;. "NOW-CONFORMiNG SYSTEM" -A prohibited system; a system located within a designated 100-year floodplain; any system which may or may not meet all the location, design, and construction standards of the current City Codes and which is failir►g for any reason; and any system with less than 3 feet of unsaturated soil or sand between the distribution device and the limiting soil characteristics. (The limiting soil characteristic_V4 has or ( I has not been identified at this time. If the limiting soil characteristic has not been identified, this classification may be subject to revision.) TANK CONDITION (5-10): ITinspection indicates: Puipout not needed at this time. Solidsaccumulation in tanks indicates they should be pumped out this year to help prevent future problems. 7 Solids accumulation in tanks is at a critical level. Yanks should k, pumped out as soon as possible. 8 System is discharging to the surface. Tanks must be pumped out wit,ln 48 hours to eliminate surface discharge 9 Inspection risers missing -tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each tank at next pumpout. if tanks have not been pumped out witr'n the last three years, they should be pulped out now. 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). If tanks have not been pupped Y out within the Last three years, they should be pumped out now. DRRAINFIELD CONDITION (11-14): D field inspection indicates: 1 Drainfield is airy, no surfacing evident. Some evidence = surfacing, not critical vet. 13 Drainfield is saturated and visibly dis-har immediately. Repairs must be complet, 14 Drainfie(d extent and condition unknown. acks.etc.)• itreated effluent to the surface. Contact the City Inspector �n 90 days. POTENTIAL FOR SYSTEM FAILURE (depends on soils.water table.etc.): COMMENTS: Date of Inspect: Septif System rhopector Note: In the event that this inspecti)r, rpp,: _ used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does .o, uarantee or certify that an existing system -ill continue to function properly, but is merely an opinion of the a. *acy of the system under current conditions based o, the available information. This report must be kept on the premises with the system location and pumping records. WHITE COPY Inspectors FIN YFA0W COPY homeowner