Laserfiche WebLink
CITY of ORONO <br />Mun(c(Ptd OfK,ces <br />Street Address: <br />2750 Kelley Parkway <br />Orono, MN 55356 <br />Owner: r� Address: 14a5 rox st. <br />Permit Vs: 9007 Dates: 5/27/97 Contractors: Sauer Trucking <br />(This is [ I an existing system Ix new construction). <br />MalUn= Address: <br />P.O. Box 66 <br />Crystal Bay, MN 55323.0066 <br />STEM COMPLIANCE (1-3): 1 <br />CY Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />codes and is functioning properly. <br />3 Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failicig to properly treat and dispose of the current <br />input; and any system with less than three feet of vertical separation between the bottoa. <br />of the drainfield and the saturated soil level. <br />(The saturated soil level I I has or [ I has not been identified at this time. If the <br />saturated soil level has not been identified, this classification is subject to revision.) <br />K CONDITION (5-9): 5 <br />5 Pumpout not needed at this time. <br />Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be pumped out and risers installed now. <br />9 Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pumped out within three years, they should be pumped out now. <br />(During the last septic tank Kaintenance Puopout the tanks 044 were or ( I were not ca9i"..rmed <br />to be watertight by the licensed pusping contractor. If the tanks were not confirmed to be <br />watertight, this classification is subject to revision.) <br />Rg�INFIELD CONDITION (11-14): 11 <br />1 Drainfield is dry, no surfacing evident. <br />Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): low <br />COKIENTS: <br />1 -41_1�? <br />Date o- f Inspedtion <br />4�� Jld"V�� <br />S pt System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tekpbw (612) 4731-7357 0 F'AX 4734510 <br />