HomeMy WebLinkAbout1375 Cherry Place - Point Of Sale Inspection - CompliantTask # 103689
Date Called in
Date Scheduled
City Of Orono Reinspected 4-15-2026
Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form
Property Address: 1375 Cherry Place
PID:0811-/23320024
'
Owner Information
Name:
Dillon Carlson
Mailing Address:
(if different from
Property)
Phone:
763-670-9776 Email: I Dillon.carlson4l@gmail.com
Inspector Information
Name:
V1 a vl C I a t-V --
Company/ Organization
City of Orono
Hi hview Plumbin
License number:
Phone:
952-249-4686 1 612-916-1685
Email:
Inspection
System
Standard
Pass
Fail
Roof Drains
Roof drains and leaders Roof drains should not be connected to the sanitary
sewer but should discharge to the ground outside of a building. If the roof
drains are connected to the sanitary sewer, disconnect them, plug any open
connections to the sanitary sewer using a non -shrink permanent material, and
redirect the roof drains onto the ground outside the building.
Foundation
Foundation drains are underground pipes that collect storm water from
Drains
around the base of a building and into a sump basket, where it is then
pumped outside of the building. Foundation drains should not be connected
to the sanitary sewer.
Sump Pumps
Sump pumps are designed to capture surface or ground water that enters
basements or crawl spaces and pump it away from the house. The basic sump
system includes drain tile, a sump pit, a sump pump, a float or switch, and a
drain line. Sump pumps should not be connected to the sanitary sewer.
Sewer Service
Sanitary Sewer Inflow & Infiltration (I/I) Compliance Inspection Sanitary
Line
Sewer Lines. All sanitary sewer lines serving Property, from the house to the
main line, shall be in a safe and functional condition and shall be free from all
leaks, failures including but not limited to partially collapsed sections or tree
root intrusion. The sanitary sewer lines shall meet the City Code standards and
specifications. Details on back of this sheet
Notes:
Repaired 4-15-2026
6" SCH 40 with Fernco, max adapter to 4" cast. - Brian Clark Task # 104077
Compliancy good through 4-15-2036
Toilet Removed
o Yes o No
For Inspection:
Inspectors Signature: Date:
Owners Signature: Date:
City Review
Nf Compliant
I ❑ Corrective Action Required
Certificate of Compliance Expires: —/
— oZ0 v
Corrective A Qtion Due b
Date: �f
Signature:
Name:
2!.