Loading...
HomeMy WebLinkAbout1987-04-16 On Site Sewage Treatment Inspection ReportOil th" North.S/.1rnt• of' Laki .tfill in, it) nk,r ON -SITE SEWAGE TREATMENT INSPECTION REPORT POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 OWNER R A Y M u t-i 0 H - tAAU` __— ADDRESS - t `*y � f-ox 2i cl(-C-32'e-410 PERMIT NO.'S. !yl`JL 1&1K 1 X_ DATES =f - — 1 L Y2- - CONTRACTORS W t 10M'-' R 8fZS City Ordinance No. 210 requires that each on -sue sewage treatment system in Orono he inspected on a regular basis. The on -site sewage treatment system at the above address has been inspected ano opears to fall into the category checked below (This is .Pan existing system ❑ new construction) 01 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating properly. 2 Does not meet all current City standards for new construction 11978 Code) but in most respects appears to be designed, located, and constructed generally in accordance with previous codes. System appears to be lunctioning properly; nu major upgrading of the system is required at this time. a 3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating adequately at this time, but has a relatively high potential for future problems. No major upgridiny A system is reyuuad.11 this time. Q 4 System may of may no; meet current City standards for design, construction or location, but e. lading to properly treat and dispose of th•t current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is creating a safety harard, w is other,* ,., -gating a public nuisance. Please contact the City Inspector to discuss system repair/ replacement procedures. If drainfiel it „-at ant is necessary, sod testing will usually be required, and a design and site plan must be submitted for review your , must obtain a permit before work is started SYSTEM CONDITION 1 60 Checked items may sct.on) Tank inspection indicates Affiturrpout not needed at this time. ❑ Solids accumulation in anks indicates they should be 1• .•np- ad out this year to help prevent future problems. ❑ Solids accumulation in tanks is at a critical level. Tank should be pumped out as soon as possible. ❑ System is discharging to surface. Tanks must be pumped within 48 hours to eliminate surface discharge. ❑ Inspection risers missing -tanks could not be inspected. Inspection risers (4" dia. pipe) must he installed in each tank at next pumpout. If tanks have not been pumped out within the lest three years, they should he pumped out now. L) Inspection pipe !s located directly over tank baffle, (Does not give accurate measurement of solids accumulatron.l 11 tanks have not been pumped nut within the last three years, they should be pumped out now. DropDml�ield inspection indicates ,kramfield is dry, no surfacing evident. U) Some evidence of surfacing, not critical yet. CJ Drainfield is saturated and visibly discharging untreated effluent to the surface. This condition may tequne replace- ment or additions to draintield. Contact the City Inspector irnmediatel,,,. Repairs must be completed within 90 days. r Drainfield extent and condition unknov. . SITE CHARACTERISTICS Limiting Site Factors Potential for System Failure ❑ Slope (depends on soil types, water ❑ Soil table, and system Londition) ❑ High water table 43-Low ❑ Lot site ❑ Medium ❑ Lake, wetland, or stream F) High ❑ Drainage L-) System is causing visible surface discharge. Site Capabilities for Future Expansion Lr�) Adequate T7`F ale Poor ❑ Inadequate COMMENTS - - ---- -- -- -- - - - — --- ---- - --- sL/ - I6 -8 — Date of Inspection tic System Inspectot Note. In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report does not guarantee or certify that an existing system wid continue to function uroperly. but is merely an opinion of the adequacy of the system under current conditions based on the available information This report roust be kept on the premises with system location and pumping records W141TE COPY Inspector's File '-,OLD COPY H,.meowner