Laserfiche WebLink
1°% <br />0 0 <br />CITY of ORONO <br />;g• �!� Municipal Offices <br />Street Address: Mailing Address: <br />'�fC$gg04 2750 Kelley Parkway P.O. Box 66 <br />Orono, MN 55356 Crystal Bay, MN 55323.0066 <br />Owner: i-�c) L� Aa' le— K l Address: 1900 Fox Ridge Rd. <br />Permit M's: 6775, 1311 Dates: 9 19/82, 10/7/66 Contractors: Widmer Bros., Widmer Bros. <br />(This is [ /I an existing system [ ) new construction) <br />SYSTEM COMPLIANCE (1-3): 3 <br />1 Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />codes and is functioning properly. <br />Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less than three feet of vertical separation between the bottom of <br />the drainfield and the saturated soil level. <br />(The saturated soil level is [ `-.] or is not [ j identified under this septic system. If the <br />saturated soil level is not identified, this classification is subject to revision.) <br />TANK CONDITION (5-5): 8 <br />5 Pumpout not needed at this time. <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be pumped out and risers installed now. <br />9 Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pumped out within three years, they should be pumped out now. <br />10 One or more tanks are cesspools, which means the septic system is nen-compliant. <br />(The tanks are [ j (•r are not [ ] water tight or the condition is [\j unknown. If the tanks <br />are not confirmed tG lie watertight, this classification is subject to revision.) <br />DRAINFIELD CONDITION (11-14): 11 <br />L- Drainfield is dry, no surfacing evident. <br />12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact <br />the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system aqe and condition, soils, etc.): medium <br />CCMMENTS: The septic system is non -compliant, but does nct appear to pose imminent threat to <br />public health or safety ;surface discharge or backup into the dwelling). The system must be <br />repaired or replaced by 12/31/2006 or within ninety days of posing an imminent threat to public <br />health or safety, whichever comes first. <br />Date of Inspection Spp it System Insp ct r <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Tekpbone (612) 473-7357 • FAX 4734510 <br />