My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1992-09-30 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
F
>
Ferndale Road North
>
797 Ferndale Road North - 36-118-23-12-0017
>
Septic
>
1992-09-30 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 10:44:03 AM
Creation date
2/18/2026 10:37:41 AM
Metadata
Fields
Template:
x Address Old
House Number
797
Street Name
Ferndale
Street Type
Road
Street Direction
North
Address
797 Ferndale Road North
PIN
3611823120017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' S-iP TESTZN 9 ZNQ Steven B. Schirmero — MPCA Cert. No. 627 <br />951 Katydid Lane NE • St. Michael, MN 55376 • (612) 497-3566 <br />September 30, 1991 <br />Paul Boyke <br />Lotl, Block 1 <br />Lauranne Woods, 10 .1/2 <br />Orono, Henn. Co., MN <br />This On -Site Sewage Treatment System is Designed for a Type 1, four <br />bed-nom home in accordance with the Minnesota Pollution Control <br />Agenc./ Chapter 7080 and local ordinances. <br />The soils on this site are SCS soils mapped - HbC - Hayden loam. <br />A seasonally high water table was located at 26" to 38", (mottled <br />soil). Due to the seasonally high water table, a Pressurized Mound <br />System will need •.-) be installed. The bottom of the rock bed must <br />be located at leas. 3' above the seasonally high water table. <br />The soils at a depth of. '2" have a percolation rate averaginq <br />6.2 min/inch. <br />A pumping chamber will need to be installed to lift the effluent to <br />the treatment area. <br />The manifold and supply line pipe must have back drainage to the pumping <br />chamber. The distribution pipes shall have their ends capped. Be sure <br />the rock and sand fill material are clean. The sod layer below the <br />entire mounded area must be turned over, just break up the sod, be sure <br />not to over work. <br />The power supply and H:.tches must be located outside the manhole and <br />pumping chamber in a weather proof enclosure. A warning device.raust <br />be installed with a light and sound device, this is in case of -a pump <br />failure. Mercury floats are a good method. <br />All neighboring wells are located greater than 100' away from the <br />proposed treatment area. <br />CONT'D <br />
The URL can be used to link to this page
Your browser does not support the video tag.