Laserfiche WebLink
Owner;_ 11 rjl ICir1�\ <br />CITY of ORONO <br />Maniew Ofllces <br />Street Address: Naft Address <br />1150 Kelley Parkway P.O. Box 66 <br />Orono, MN 55356 Crystal Bay, MN 55323.0066 <br />Address:763 Ferndale Rd. N. <br />Permit #1s:8187 Dates:11/14/85 Contractors:Quickway Sxc. <br />(This is I an existing system [ ] new construction) <br />SYSTEM COMPLIANCE (1-3): 3 <br />1 Code System: Meets or exceeds current City standards in all respects rel.acing to <br />design, construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, <br />but in most respects appears to be designed, located, and constructed in accordance <br />with previous codes and is functioning properly. <br />3 Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the <br />current input; and any system with less than three feet of vertical separation <br />between the bottom of the drainfield and the saturated soil level. <br />(The saturated soil level [ has or ( j has not been identified at this time. If the <br />saturated soil level has n{t been identified, this classification is subject to revision.) <br />TANK CONDITION (5-9): 9 <br />5 Pumpout not needed at this time <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been <br />pumped out within three years, they should be pumped out and risers installed now. <br />0 Inspection pipe is located over tank baffle -can not measure solids accumulation. If <br />tanks have not been pumped out within three years, they should be pumped out now. <br />(During the last septic tank Maintenance Pumpout the tanks ( ] were or O� were not <br />confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br />confirmed to be watertight, this classification is subject to revision.) <br />DRAINFIELD CONDITION (11-14): 13 <br />11 Drainfield is dry, no surfacing evident. <br />2 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition soils etc.): failing <br />COMMENTS: Repairs must be completed by 8/31/96. <br />Date of Inspection <br />SpIptic System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue <br />to function properly, but indicates the operation of the system under current conditions. <br />Telepbesee (612) 473.73P 0 FAX 473MIS <br />