Laserfiche WebLink
On for ."if'ortb Shore of' <br />Lake Minnetonka <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />OWNER --i_L 1 `' - ---- - --- -- ADDRESS '�� i— " f_0?iVaE ell) _ <br />PERMITNO.'S. - E Z DATES Z J� SV ---- ---. CONTRACTORS "A"* - <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular wvs. The on4bte if go <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(Thisis Fan existing system 17 new construction) <br />01 Meets or exceeds current City standards in all rest ects relating to design, construction, and location. Appears to tie ,rating <br />p•operly. <br />2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, and constructed generally in accordance with previous codes. System appears to be functioning properly, no major <br />upgrading of the system is required at this time. <br />3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be ulrer,u.ng <br />adequately at th. ave. but has a relatively high potential lot future problems. No major upgrading of system is required at <br />this time. <br />4 System may of may not meet current City standards for de,rgn, construction or location, but is fading to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface. or groundwatees, or is <br />creating a safety ha.•ard, or is otherwise creatinq a public nuisance. Please contact the City Inspector to discuss systL,i repair; <br />replacement procedures. If drainfield replacement is necessary, sod testing will usually be required. and a design and .tie plan <br />must be submitted for review. Your conti. -tor must obtain a permit before work is started. <br />SYSTEM CONDITION 1 fa Checked items may requir- your action) <br />Tenk inspection indicates <br />Pumpout not needed at this time. <br />❑ Solids accumulation in tanks indicates they should be pump- <br />ed out this year to help prevent future problems. <br />L Soiids accumulation in tanks is at a critical level. Tanks <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to eliminate surface discharge. <br />❑ Inspection risers missing -tanks could not be inspected. <br />Inspection risers (4" dia. pipe) must be installed in each tank <br />at next pumpcut. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />SITE CHARACTERISTICS <br />Limiting Site Factor% <br />n Slope <br />❑ Soil <br />❑ High water table <br />❑ Lot sr>e <br />❑ Lake, wetland, or stream <br />❑ Drainage <br />FJ Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three veers, they <br />should be pumped out now. <br />Drat inspection indicates <br />Lid' Drainlield is city, no surfacing evident. <br />❑ Some evidence of surfacing, not critical yet. <br />❑ Drarlield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace- <br />ment or additions to diainfield. Contact the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />n Drainlield extent and condition •inknown. <br />Potential for System Failure <br />Sri, Capabdih!s for <br />Idepends on soil types. water <br />F uh,m Expansion <br />Adequate <br />cable. aid system ionditron) <br />t�J <br />._1 Low <br />`1 Fair <br />C ] Ii <br />1 I Poor <br />l.1 Hiyn <br />i Inadequate <br />Li System is causing visible <br />surface dischargr <br />COMMENTS—_-- <br />-- - - - - <br />Onto of Inspection Se is System Inspector <br />Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other if nsfer of property, be advised that <br />this report does not guarantee or certify that an existing system will continue to function prolwily but is nareiy an opinion of the adequacy <br />of the system under cut tent conditions based on the available information. <br />This report must he kept on the premises with system location and pumping records <br />WHITE COPY i Inspector's File Got 0 COPY / Homeowne, <br />