HomeMy WebLinkAbout1987-06-30 On Site Sewage Treatment Inspection ReportON -SITE SEWAGE TREATMENT
INSPECTION REPORT
OWNER
PERMIT NO.'S.
DATES
On Hit, rYortlr Short- of
Lake Minnetonka
POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
ADDRESS 53LS blot i k T-0 ndct If )nc..;,i
CONTRACTORS
City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewage
trMtment system at the above address has been inspected and appears to fall into the category checked below.
(This is J, an existing system ❑ new construction)
1 Masts or exceeds current City standards in NI respects foisting to design, construction, and location. Appears to be operating
properly.
192 Does not most oil current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System �irppoors to be functioning properly. no rnsior
upgrading of the system is requited at this time.
El3 Does not meet current City standards in many respects relating to design, construction, or location. Appears io be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may of may not meet current City standards for design, construction or location. but is fading to properly treat and
dispose of the current input, and is andongering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, of is othervino creating a public nuisance. P;aaW ^ontact the City Inspector to discuss system repair/
replacement procedures. If drainfield replscernent is nepsury, sod tesb-ig will itsually be required, and a design sod site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION 1 m Chocked *ems may require your action)
Tank inspection indicates:
Pumpout not rsaaded at this time.
Solids accumulation in tanks indicates they should be pump-
ed out this yaw to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must be pumped
within 49 hours to eliminate surface discharge.
❑ Inspection riswt missing —tanks could not be inspected.
Inspection risers 14" dia. pipe) must be installed in each tank
at next punpout. If tanks have not been pumped out within
the last three yews, they should be pumped out now.
SITE CHARACTERISTICS.
Limiting Site Factors
❑ Slops
❑ Soil
❑ High wow table
❑ Lot sore
❑ Lake, wetland, or stream
❑ Drainage
COMMENTS
❑ Inspection pipe is loafed directly over tank baffle. loans not
Vivo accurate msasun nGnt of riolids accumulation.] If tanks
have not been pumped out within the last three yaws, they
should be pumped out now.
Drainfield inspection indicates:
ja Drainfield is dry. no surfacing evident • r• Q�� �� `� a rtt2at.�
❑ San M evidence of surfacing, n.3t critical yet.
❑ Droinfieltl is saturated and visibly discharging untroatad
effluent to the surface. This condition may tegwro replace-
maint of additions to dramlel4. Cc,!tact the City Inspector
emrred)ately. Repairs must he completed within 90 dps.
❑ Drainfield extent and condition unknown.
Potential for System Failure
(depends on soil types, water
table, and system condition)
❑ Low
® Medium
❑ High
❑ System is causing visible
surface discharge.
Site Capabilities for
Future Expansion
❑ Adequate
® Fair
❑ Poor
❑ Inadequate
Y 7 _mil rte-
Date of Inspection Septic Syfe1hJnsWtor
,I
Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
Of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping records
WHITE COPY I Inspector's File COLD COPY / Homeowner