HomeMy WebLinkAbout1987-06-29 On Site Sewage Treatment Inspection ReportOn the ,Vorth Shorn of'
Lake ,,,limp tonkip
ON -SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473.7357
OWNER FJvJckN . -(-�Phen _-- ADDRESS r 0QL
PERMIT NO.'S. S 7 /0 -- DATES Q - l L, - -79 CONTRACTORS 141%d�-610�-
City Ordinance No. 21fJ requires that each on -site sewage treatment system in Otono be inspected on a regular basis. The on site sewage
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is N an existing system ❑ new construction)
El1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appeats to be operating
properly.
122 Does not meet all current City standards for new construction 11978 Code) bit in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
a 3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
❑ 4 System may or may not meet current City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, nr is otherwise creating a public nuisance. Please conts, t the City Inspector to discuss system repair/
replacement procedures. If drainfreld replacement is necessary, sod testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION 10 Checked items may require your action)
Tank inspection indicates:
❑ Pumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should he pump-
ed out this year to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must be pumped
w,lhin 48 hours to eliminate surface discharge.
1K Inspection risers mining —tanks co,.d not be inspected.
Inspection risers 14" die. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
❑ Inspection pipe is located directly over tank baffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three Veers, they
should be pumped out now
Drainfield inspection indicates.
Drainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace•
ment or additions to droinfield. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
❑ Drainfield exten, and condition unknown.
SITE CHARACTERISTICS
Limiting Site Factors Potential lot System Failure
Site Capabilities for
❑ Slope (depends on soil types. water
Future Expansion
❑ Soil table, and system condition)
❑ Adequate
❑ High water table ❑ Low
® Fair
❑ Lot size ® Medium
n Poor
® Lake, wetland, or stream ❑ High
❑ Intidequate
❑ Drainage ❑ System is causing visible
surface discharge.
1 1_ )
T k-, AJ +
�F
COMMENTS tl :Ail o C]w- PLA , n,-.y l Cit-
+7 JQ J LJC'C1.l1f,4j,I Qn t,ra (2rY) CLi�f
--
_
Date of Inspection Septic Srs Spector
Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised Mal
this resort does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
of the system under turn nt conditions based on the available information
This report mull to kept on the premises with system location and pumping records.
WHITE COPY r Inspector's Fit,- GOLU COPY i Humeowner