HomeMy WebLinkAbout1990-07-02 On Site Sewage Treatment Inspection Reporttlu !lit' .\1)1Ih Sir uJ
/.ike tfumetnuk..
ON -SITE SEWAGE TREATMENT CITY
INSPECTION REPORT If F POST OFFICE BOX 66
O . O O 1335 S. Brown Rd.
ilk Crystal Bay, MN 55323
473-7357
OWNER __-Z�L1��� .sL �__nl ADDRESS &22:4
PERMIT NO.'S. - DATES —_— CONTRACTORS
City Ordinance No. 210 requires that each on -site sev.age treatment system in Orono be wspected on a regular basis. The on -site sewage
treatment system at the above address has been ,nspected and appears to fall into the category checked below.
I1 his is 0 an existing system ❑ new construction)
1 Meets or exceeds current r.. ttandards in all respects relating to design, construction, and location Appears to he olierating
properly.
02 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be desiyud,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly: no ria)or
upgrading of the system is ret, red at this time.
El3 Does not meet current City standards in many respects elating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is (equired at
this time.
El4 System may or may not meet runent City standards for design, construction or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a sour;e of pollution to surface or groundwatets, or .s
creating a safety hazard, or is otherwise creating a public i.cesdnce. Please contact the City Inspector to discuss system repair/
replacement procedures. If draintiefd replacement is necessary, sod testing will usually be required, and a destgo and site plan
must be submitted lot review. Your contractor must obtain a permit before work .; started.
SYSTEM CONDITION f m Checked ,tems may require our action)
Tank inspection indicates
❑ Pumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should :)e pump-
ed out this year to help prevent futit- problem ..
❑ Solids accumulation in tanks i, at a critical level. Tanks
should be pumped out as s wn as possible.
❑ System is discharging to surface. Tanks must be pumped
within 48 hours to eliminate surface discharge.
Inspection risers missing —tanks could not be inspected.
Inspection risers (4" dia. pipe) must be installed in each tank
at next pumpout. If tanks have not Wen pumped out within
the last three years, they should be pumped out now.
SITE CHARACTERISTICS
Limiting Site Factors
❑ Slope
❑ Sod
❑ High water table
❑ Lot size
❑ Lake, wetland, or stream
❑ Drainage
❑ Inspection pit a is located directly over tank baffle. (Does not
aive accurate measurement of solids accumulation.) If tanks
have not been pumped out within the lest three years, they
should be pumped out now.
Drain field inspection indicates
Grainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to drainfield. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
❑ Dramfield extent and condition unknown.
Potential lot System Fadu;9
Idepends on soil types, vat, r
table, and system condition)
Xr Low
❑ Medium
❑ High
❑ System is causing visible
surf a discharge
Site Capab. ..es for
FutExpansion
ur
Adequate
❑ Fair
(1 Poo.
t I Inadequate
COMMENTS �% —kl —iIJrl �
Arne cam,!/ ems.
Date of Inspection &eptic System Inspector
Note. In the event that this inspection report is used to satisfy the tPiluirements for a mortgage or other trarsfer of utopetty, be advised that
this report does not guarantee or certify that an existing system rntf continue to function properly, but .s merely an opinion of the adequacy
Of the system under current conditions based on the available information
This report must he kept on uir premises with system location and purnpinq records
WHITE COPY Inspei to, % Fite GOLD COPY i Homeowner