HomeMy WebLinkAbout1990-07-01 On Site Sewage Treatment Inspection ReportOn tht• ,Vorlh Soon, of
Lake Slintwtonkt►
ON -SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER ADDRESS
7
PERMIT NO.'S. -- DATES 56 CONTRACTORS
City Ordinance No. 210 requii es that each on -site sewage treatment systern in Orono be inspected on a regular basis. The on site sewage
treatment system at the above address has been inspected and appears to fall irto the category checked below.
(This is 2d an existing system ❑ new construction)
D1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating
properly.
f� 2 Does not meet all current City standards for new construction 11978 Code) but in most respects appears to be designed,
�y located, and constructed generally in accordance with previous codes. System appears to be functioning properly, nu major
upgrading of the system is required at this time
E33 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may or may not meet current City standards lot design, construction or location, but is failing to properly treat and
dispose of the cur,ent input, and is endangering a water supply, or IS a source of pollution to surface or groundwateis, or is
creating a sa eiy ha. ]rd, or is otherwise creatinq a public nuisance. Please contact the City lnspector to discuss system repair/
replacement procedures. If dr, ..Id replacement is necessary, sod testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( I0 Chucked ,tems ray require your „coon)
Tank 'nspecbon indicates
Pumpout not needed at this time.
Solids accumulation in tanks indicates they should be pump.
ed out this year to help prevent biture problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection risers missing —tanks could not be inspected.
Inspection riser, 14" dia. pipet must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should he pumped out now.
SITE CHARACTER itTlt S
Limiting Site Factors
❑ Slope
❑ Soil
❑ High water table
❑ Lot sire
❑ Lake. wetland, or stream
❑ Drainage
COMMENTS
—ZV--L`� _ -
Date of Inspection
❑ Inspection pipe is located directly over tank baffle. IDoes not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three years, they
should be pumped out now.
Dramfield inspection indicates.
D1 Dramfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Dramfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to drainheld. Contact the City Inspector
immediately Repaits must be completed within 90 days.
❑ Dramfield extent and condition unknown.
Potential for System Failure
Site Capabdit,es for
Idepends on sod types, water
F utute E xpansion
table, and system condition)
1 ! Adequate
Q� Low
Fair
❑ Medium
Poor
C7 High
❑ Inadequate
U System is causing visible
surface discharge
ptic System Inspector
Note In the event that this inspection report is used to satisfy the n •uirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but ,s merely an opinion of the adequacy
of the systern under current conditions based on the available information
Thts report must be kept on the piemtses with system location and pumping records
WHITE COPY , Inspector's file COLD COPY I Homeowner