HomeMy WebLinkAbout1998-07-07 On Site Sewage Treatment Inspection ReportC of ORONO
CNOM,, '�, • '
� itro>tt A/IA>M OWN" A1"s:
2750 IWkiy Pxkwsy P.O. Box 66
_ Orono, W 553% C") Boy, 0 55323MM
Owner: Address: 503 Ferndale Rd. N.
Permit N's: 8251 Dates: 8/13/99 Contractors: Sullivan
(This is W an existing system I ) new construction).
YSTEM COMPLIANCE (1-3): 1
Code��S st�em: Meets or exceeds current City standards in all respects relating to design,
conatriuct oon, and location. Appears to be operating properly.
2 Compliant System: Does not meet all current City standards for now construction, but in
most respects appears to be designed, located, and constructed in accordance with previous
codes and is functioning properly.
3 Non -Compliant System: System may or may not meet current City standards for design,
construction. or location, but is failing to properly treat and dispose of the current
input; and any system with less than three feet of vertical separation between the bottom
of the drainfield and the saturated soil level.
(no saturated soil level is (XJ or is not ( ) identified under tW' Cite systm. If the
saturated soil level is not identified, this classification is subject 4 _=vision.)
K CONDITION (5-9): S
5 Pumpout not nodded at this time.
Solids accumulation in tanks indicates they should be pumped out this year.
7 System is discharging to the surface. Tanks must be pumped out within 48 hours.
8 Inspection risers missing -tanks could not be inspected. If tanks have not boon pumped out
within three years, they should be pumped out and risers installed now.
9 Inspoction pipe is located over tank baffle -can not measure solids accumulation. If tanks
have not been pumped out within three years, they should be pumped out now.
10 One or more tanks are cesspools, which means the septic system is non -compliant.
(no tanks are 1"AL or are not [ ) water tight or the condition is ( ) unknown. If the tanks
are not confirised to be watertight, this classification is subject to revision.)
AINFIELD CONDITION (11-14): 11
1 Drainfield is dry, no surfacing evident.
Some evidence of surfacing, not critical yet. Repair is not required act this time.
13 Drainfield is saturated and visibly discharging untreated effluent to the surface.
Contact the City Inspector immediately. Repair must be completed within 90 days.
14 Drainfiold extent and condition unknown.
POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): low
COMENTS:
2:2JU gJJZ&
Gate of Inspection opt c System Inspector
Note: In the event that this inspection report is used to satisfy the requirements for
transfer of propErty, this report does not guarantee that an existing system will continue to
function properly, but indicates the operation of the system under current conditions.
Tdeph ■e (612) 473-7337 a FAX 4734610