HomeMy WebLinkAbout780 Long Bridge Lane - Point Of Sale Inspection - CompliantCERTIFIED W W� EXPIRES: l ao�a03'5� City Of Orono Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form Date Called in :/ zd26S Date Scheduled 9- zZ -ZOZS` Property Address: '7�p Z�„ /Iie &W GgnL PID: C l( a DOb Owner; Information Name: , a �oq Mailing Address: (if different from Property) -�*o L63 �,;c/� Lljnc Go.,,r GtiK. ,N- 55356 Phone: 61Z - Zo✓ • 74 7 Email: Me „dd Pm e jr e Ins eetor Information Name: Geer/i n s Company/ Organization /lo„ �- Ste- /?A License number: PC 779 Phone* /L- 72y-$?:S,' Email:ot�'r« a?M141ei..« As/• lv� Ins ection System Standard Pass Fail Roof Drains Roof drains and leaders hoof drains should not be connected to the sanitary sewer but should discharge to the ground outside ofa building, If the root' A\�� drains are connected to the sanitary sewer, disconnect them. plug any open �I�V} connections to the sanitary sewer using a nun -shrink permanent material, and nl�a rcdfrccl the roof drains onto the round outside the building, 1 I 1 Foundation Foundation drains are underground pipes that collect storm water from Drains around the base of a building and into a sump basket, where it is then C (y pumped outside of the building. foundation drains should not be connected to the sanitary sewer. Sump Pumps Sump PUMPS are designed to capture surface or ground water that enters \ basements or crawl spaces and pump it away from the house. The basic sump �1 p� �Q(� 1>` system includes drain tile, a sump pit. a sump pump, a float or switch, and a drain line. Sum pumps should not he connected to the sanitary sewer. I I15 Sewer Service Sanitary Sewer Inflow & Infiltration (111) Compliance Inspection Sanitary Line Sewcr Lines. All sanitary sewer lines serving Properly. from the house to the main line. shall be in a safe and litnctional condition and shall he free Isom till leaks, failures including but not limited to partially collapsed sections or tree root intrusion. The sanitary sewer lines shall meet the City Code standards and specifications. (Details on back of this sheet) Notes: Toilet Removed o Yes o For ins ection: Ci Review ri Com liant ❑ Corrective Action Re uired Certificate of Compliance Ex ires: ►v pad ; Corrective Action Due by: Date: D 0 0) 2 Signature: / Name: u l F3 2 z c Service Line Inspection Details Weather Conditions: Approximate Depth of Service Type and Size of Service Overall Condition of Service Pie '��c� Co„dr fi►�h Please note all connections, fittings, points of concern on service line including infilt►•ation, tree root, cracks, misaligned joints, etc. This report must include a digital copy of the televising. Feet Comment Example: 0 Start for 4" cleanout in NE corner of Basement 1=10 Misaligned joint —Infiltration j 9/?s PVG a6r� la s tcvt! /ors' � �• � S �/I'ac- _ /'ia� r7c1 Scc aKY /SSriaj pr• L'oti«rnS. i i } Private Property Inflow And Infiltration Inspection Procedures For Contractors Sewer Service Further Investigation Issues Properties found in need of further investigation have one or more of the following. • unable to access sewer lateral due to un-located cleanouts (behind walls, under flooring, etc) • unable to complete inspection of sewer lateral due to roots, solid deposition, crushed pipe, etc • unknown connections (unable to verify connection flowing water into sewer lateral) .And Process • Inflow/Infiltration Compliance Inspection form •Correctly plumbed sump pump discharges must have the "Sump Pumps" and "Foundation outside of the building using rigid pipe. Pipe Drains" sections completely filled out for the discharge should be a minimum of 10-feet from inspection to be complete, building. • Every sump pump on the property is required to • Sump pumps that do not discharge outside be inspected (including photos of the opened are incorrectly plumbed and are considered basket, the surrounding area, and the discharge non -compliant. pipe, both interior and exterior). Total number of Roof leaders are required to discharge outside sump pumps must be noted. of the building; any roof leaders and or cisterns • Sump pump discharge piping is required to be discharging into foundation drains are non- rigid pipe. Flexible pipe, shut-off valves, compliant. vlumbinR tees, and w es are not allowed. Completed Inspection • Property owner is to sign the completed • The City will issue either a Certificate of Inflow/Infiltration Compliance Inspection form and Compliance or a Correction Notice once the retain a copy for their records, review is complete. If a correction notice is • A copy of the completed Inflow/Infiltration issued, the required repairs must be made and a Compliance Inspection form and video link is post -repair televised inspection must be required to be delivered to the City of Orono for performed in order to receive Certificate of review. Compliance. • The City's Utilities Supervisor or his/her • The completed forms will be mailed to the designee will review the video and compare it with address on the Inflow/Infiltration Compliance the completed Inflow/Infiltration Compliance Inspection form, unless a different address is Inspection form noted. Contractor's Contractor completing the Inflow and Infiltration Compliance Inspection has read and understands the conditions of the Private Property Inflow and Infiltration inspection Procedures for Contractors. Company /name Inspector name �Oh fi7c4 SYkXi iL{f. .��-� U Copy of plumbers license On file (or) Attached License number Bond Date Staff Use Only Date Received Staff Name and Signature I%Olaoa- 5�- 11 A Page 2 of 2 s s Y s s Private Property Inflow And Infiltration Inspection Procedures For Contractors The following instructions and standards are intended for property owners and their contractors when choosing to use a private contractor to complete the Point of Sale Sanitary Sewer Service Inflow and Infiltration (1/1) Inspection. Private inspection contractors will need to complete the inspection using the City of Orono's Inflow/Infiltration Inspection Form, available on the City website. Inspectors will require access to the basement or lowest level in the home or building and access to all sewer cleanouts, sump pump(s), and sump pump plumbing. The televised portion of the I/1 inspection is to note defects in the sanitary sewer lateral, which result in infiltration and ex -filtration. The purpose of the private property inflow and infiltration (I/I) inspection is to reduce the flow of clear water into the sanitary sewer system via cross connections (inflow) from sump pumps, foundation drains, roof leaders, cisterns, and other clean water sources connected to the sanitary sewer system. In addition, the program aims to reduce indirect flow of clean water into the sanitary sewer system (infiltration) through pipe and pipe joint defects. Video Y Picture Standards • The video report will be in a MPEG format • Still photos will be in a JPEG format • Video reports can be submitted on thumb drives or a USB hard drive. • Reference the start and end of each video segment as it begins. • Footages along the sewer service line must be shown on the video report. • The video camera shall be guided forward at a moderate to slow pace along the bottom of the pipe. • The camera shall stop at any connection. • The camera shall stop at any unusual instances that are viewed while in progress and provide a more ietailed and longer view of the specific instance (i.e. — bad joint, dirt in lines, settlement in line, etc.). Sewer Service Inspection Criteria And Process • in Compliance Inspection form must be completely tilled out for the inspection to be complete. • The inspector is required to note all defects and footage location in the sanitary sewer lateral on the compliance inspection form and an audio description recorded on USB Thumb drive or hard drive. • The sewer service inspection inust the service Ape from before it exits the building to the sewer main. • All connections must be verified by flowing water into drains, referencing the source, and reporting them on the video • Any connection that cannot be verified is considered to be an unknown connection and must be exposed to verify source. • All cleanouts are required to be opened and inspected (include photos of the opened cleanout riser); cleanout inspection requires documented footage location on the form and audio description recorded on USB Thumb drive or hard drive. • All floor drains will need to be opened and inspected (include photos of the drain, the surrounding area, and the nearest foundation wall). • Any foundation drains found will need to be opened and the discharge point verified (include ph)tos). • All external drains will need to be opened and the discharge point verified • Defects/items that require documentation include, but are not limited to: Y roots Y offset pipe joints Y mineral deposits unknown deposits or Sag/pipe deflection i- cracked pipes 'r chipped pipes Pipe size transitions length of service location of all cleanouts broken / damaged or missing pipe foundation drain connections (including photos). Page 1 of 2 i E