HomeMy WebLinkAbout1987-06-25 On Site Sewage Treatment Inspection ReportOff Me .Vortb Sbore of
ON -SITE SEWAGE TREATMENT ).tier .Sfiurrrlorrkir
INSPECTION REPORT POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER _1421Ct � �1. 1i � ri'r fl,a �1 i _ ADDRESS -�� �'-' P�Or` rz_c r •.r +Lt � ���
PERMITNO.'S. r DATES -- - CONTRACTORS
City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. The on -site sewew
treatment system at the above address has been inspected and appears to fall into the category checked below.
(This is ® an existing system ❑ new construction)
1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating
properly.
® 2 Does not meet all current City standards for new construction (1978 Codel but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgreding of the system is required at this time.
03 Does not meet current City standards in many respects relating to design, construction, or location. Amseart 10 be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
04 System may o, may not meet current City standards lot design, construction of location, but is fading to properly treat and
dispow of the current input, and is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety harard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION 1 m Checked items may require your action)
Tank inspection indicates
® rumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should be pump•
ad out this yew to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection rivers missing -tanks could rot be inspected.
Inspection risers (4" die. pipe) must be installed in each tank
at neat pumpout. If tanks he" not been pumped out within
the last three years, they should be pumped out now.
SITE CHARACTERISTICS.
Limiting Site Factors
❑ Slope
❑ Soil
❑ High water table
❑ Lot care
❑ Lake, wetland, or stream.
❑ Drainage
❑ Inspection pope is Iocatld directly over tank baffle. (Dan not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the Iasi three years, they
should be pumped out now.
Drainfield inspection indicates
m Drainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace.
ment or additions to drainfield. Contact the City Inspector
immediately. Rvpairs must be completed within 90 days.
❑ Drainfield extent and condition unknown.
Potential for System Failure
Idepends on soil types, water
table, and system condition)
❑ Low
f1] Medium
f[7 High
❑ System is causing vitihie
surface discharge.
COMMENTS D1tr
Site Capabilities for
Future Exp,. r,sion
❑ Adequate
;r Fair
n Poor
�) Inadequate
i I _i /'t' _ _x �� l _ j ! 7 ----- •Lmil' L<2 .' ' � r f t� �- - ---- —
Date of Insi4ecti ion Septic S tenl Inspector
Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
Of the system under current conditions based on the available information
This report must he kept on the premises with system location and purnpinq records
WHITE COPY I Inspector's File GOLD COPY , Hurneowner