HomeMy WebLinkAbout1978-11-01 Final Inspection SheetFINAL INSPECTION SHEET Address Permit # 1. House numbers must be correct, and located so they can be read from the road 2. Garage: a) Firewall from floor to ceiling completed b) Firewall taped ,L c) Access to attic must have 1 hr rated covering d) Must have solid core door w/ closer between garage and house if e) Living area above garage -ceiling must be fireprotected and taped f) Remarks - 3. First Floor: a) Railing, side protection where required OKK b) Smoke det. in hallways where bedrooms are located L (not more than one foot from ceiling) ,Ve c) Fireplaces: v 1. Hearth extention - 20 in. minimum 2. Fireplace depth d) Remarks - 4. Basement: a) Railings, side protection G ��- b) Bridging in and nailed (12" depth or more) c) Rim joist i.nsul. AWE d) Styro insul. covered w/ 20 min rating e) Remarks - 5. Mec:h.Systems Permit # a) Furnace 1. Capacity (M .put -_ unit) i��f►�/ ODoo 2. Type of system 3. Duct work (f5'e_- b) Exhaust fans (vent to outside) C�3 eC- c) Water heaters 1. Relief valve - maximum 3" off flcor d) Remarks - 6. Second Floor a) Attic access b) Smoke det. where required c) Railings —'- d) Remarks - 7. Electrical finaled 8. Sewer or septic (finished) Permit # . 9. City w-L.ter or well Permit # 10. Plumbing Permit #