Laserfiche WebLink
�o� <br />0 0 <br />CITY of ORONO <br />himic[pa) omcea <br />SUM Address: Ms06sj Address: <br />�gQ4� 2750 Kelley Parkway P.O. Box 66 <br />Orono, MN 55356 Crystal Bay, MN 55323.0066 <br />Owner: IbLJ) Address:3067 Farview Ln. <br />Permit #'s:5293 Dates:8/28/78 Contractors:Sullivan <br />(This is X] an existing system ( ] new construction) ' <br />SYSTEM COMPLIANCE (1-3): 3 a <br />1 Code System: Meets or exceeds current City standards in all respects relating to <br />design, construction. and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, <br />but in most respects appears to be designed, located, and constructed in accordance <br />with previous codes and is functioning properly. <br />[3 Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the <br />current input; and anX system with less than three feet of v a1 s an <br />between ttte bottom o d—the_-saturated..soi --leve ._ <br />.(The saturated soil levaI ' has or [ ] has not been identified at this time. If the <br />saturated soil level has nit been identified, this classification is subject to revision.) <br />TANK CONDITION (5-9): 9 <br />5 Pumpout not needed at this time <br />6 Solids accumulation in tanks indicates they should be pumped out this year. <br />7 system is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been <br />pumped out within three years, they should be pumped out and risers installed now. <br />6) Inspection pipe is located over tank baffle -can not measure solids accumulation. If <br />tanks have not been pumped out within three years, they should be pumped out now. <br />(During the last septic tank Maintenance Pumpout the tanks [ I ware or (x] were not <br />confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br />confirmed to be watertight, this classification is subject to revision.) <br />INFIELD CO I1.Of1 (11-14): 11 <br />Drainfield is dry, no surfacing evident. <br />12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): medium <br />COMMENTS: The non -compliant septic system must be repaired by 12/31/96 or within 90 days <br />of failure (surface <br />ddisch(arge). U <br />AM,- <br />rl_ <br />Date of Inspection Sep is System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue <br />to function properly, but indicates the operation of the system under current conditions. <br />Tekpboee (612) 473-7357 9 FAX 473MIS <br />