Laserfiche WebLink
0 0 <br />CITY of ORONO <br />,�. Munkipd oPlkes <br />+ G <br />` Street Addms: MaNinB Address: <br />K$gg04� 2750 Kelley Parkwa- P.O. Box 66 <br />Orono, MN 5535k Crystal Bay, MN 55323-0066 <br />Owner: ���� / / _ Address:3060 Farview Ln. <br />Permit #'s:1903, 4913 Dates:5/15/89, 8/19/77 Contractors:Volkenant, Sullivan <br />(This is X an existing system ( l new construction) <br />SYSTEM COMPLIANCE (1-3): 3 <br />1 Code System: Meets or exceeds current City standards in all respects relating to <br />design, construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards fcr new construction, <br />but in most respects appears to be designed, located, dnd constructed in accordance <br />with previous codes and is functioning properly. <br />Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the <br />current input; and any s::stem with less than three feet of vertical separation <br />between the bottom of the drainfield and the saturated soil level. <br />(The saturated soil level Y'4 has or [ ) has not been identified at this time. If the <br />saturated soil level has not been identified, this classification is subject to revision.) <br />TANK CONDITION (5-9): 6 <br />5 Pumpout not needed at this time <br />i� Solids accumulation in tanks indicates they should be pumped out this year. <br />System is discharging to the surface. Tanks must be pumped out within 48 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been <br />pumped out within three years, they should be pumped out and risers installed now. <br />9 Inspection pipe is located over tank baffle -can not measure solids accumulation. If <br />tanks have not been pumped out within three years, they should be pumped out now. <br />(During the last septic tank Maintenance Pumpout the tanks [ I were or [ ] were not <br />confirmed to be watertight by the licensed pumping contractor. If the tanks were not <br />confirmed to be watertight, this classification is subject to revision.) <br />INFIELD CONDITION (11-14): 11 <br />Drainfield is dry, no surfacing evident. <br />12 Some evidence of surfacing, not critical yet. Repair is not required at this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. <br />Contact the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (sY_•tem age and condition, soils, etc.): low <br />COMMENTS: The non -compliant septic system must be repaired by 12/31/96. <br />Date of Inspection System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue <br />to function properly, but indicates the operation of the system under current conditions. <br />Tekpbw (612) 473-7351 • FAX 473-4614 <br />