HomeMy WebLinkAbout1978-01-24 Septic System Design ReportAn Expansion of Soil Engineering Services, Inc
'O MINNEAPOLIS/ST. PAUL 6880 S. County Rd. 18, P.O. Box 35108, Mpls„ Mn. 55435 / 612 941 5600
❑ NORTHERN MINNESOTA 3219 E. 19th Avenue, Hibbing, MN. 55746 / 218-263-8869
❑ CENTRAL MINNESOTA 200 Osao Avenue No., St. Cloud, Mn. 56301 / 612 253 9940
January 24, 1978
David Nitz, Inc.
464 Second Street
Excelsior, MN 55331
Attn: Mr. Scott Abernathy
Gentlemen:
Braun"
ENGIKEEAING TESTING
1 S BRAUN P E Pfa,drnr
P K ANDERSON, Vr Pn OpprPrwnr
L G KR USE P. E.. Vrctr AK Enpn ng
Re: 78-008A SOIL BORING & PERCOLATION
'TESTS
Lot 10, Block 1
Farview Addition
Orono, Minnesota
As you requested, we have recently conducted one power auger
boring and ten percolation tests taken to determine the
general soil and water conditions, as well as to provide
information relative to the soil absorptivity rates for an
individual sanitary System being constructed at the above
referenced lot. Boring and percolation tests were taken at
the locations shown on the attached sketch. Field locations
were determined Sy our crew with reference to the staked
house location. Surface elevations were referenced to the
top of an iron at the northeast property corner with an
elevation at this point assumed equal to 100.0.
Initially, six percolation tests were conducted on the lot
on January 6, 1978. As some of the tests indicated failing
results, four additional percolation tests were conducted on
January 13, as you requested.
INVESTIGATION METHODS:
The power auger boring was completed using a truck -mounted
power auger unit. The soil classifications and depths shown
on the attached log were inferred from the soils brought to
the surface by the continuous flight feature of the auger.
The depth of s`rata changes are thus considered approximate.
CONSULTING ENGINEERS/SOILS AND MATERIALS
Test Borings • foundation Engineering and Recommendations a Inspection of Construction • Material Testing of Sods. Concrete and Budding Components
' 78-008A
' David Nitz, Inc. -2- January 24, 1978
Mineral soils encountered in the boring were classified in
' accordance with the Unified Soils Classification System
(ASTM D2487). A copy of that chart is attached. Representa-
tive samples were then returned to our laboratory for
' verification of the field classification by a Soils Engineer.
Representative samples will remain in this office for a
period of 60 days to be available for your examination.
' The boring was probed immediately after its completion to
check for the presence of groundwater. The boring was also
rechecked prior to leaving the site at the time the percola-
tion tests were read the following day. Groundwater was not
encountered in both probings of the boring to its 17-foot
termination depth.
H
J
II
II
u
11
The percolation tests were run in 6-inch diameter holes
drilled to an approximate depth of 36 inches, in accordance
with pr;,,.edures recommended by the Minnesota Department of
Health (WID) and with procedures recommended by the City of
Orono. In accordance with these procedures, the bottom and
sides of the holes were scr.:tched with a knife blade to
remove any smeared soil surfaces and to provide a natural
soil interface into which the water may percolate. Two
inches of coarse sand was then placed in the bottom of the
holes to prevent scouring. The holes were then carefully
filled with clear water to a minimum depth of 12 inches over
the top of the sand layer and allowed to soak overnight with
the percolation tests being conducted the following day.
RESULTS:
The log of soils encountered in the boring and the water
level observations are shown on the attached Log of Boring
sheet.
The soil boring generally encountered a coarse alluvial
silty sand from the surface to the 5-foot depth. A silty
clayey sand to sandy clay glacial till was then encountered
to the termination depth of the boring. Soils encountered
in the percolation tests generally ranged from sandy silty
sand to a sandy clay glacial till.
Results of the six initial percolation tests indicating the
soil absorptivities in minutes per inch (mpi) are as follows:
Surface
Soil At
Rate
Test #
Elevation
Test Depth
(m i
P-1
83.1
Silty Sand
48
P-2
78.8
Sandy Clay
120
P-3
75.9
Sandy Clay
120
P-4
75.5
Sandy Clay
80
P-5
76.3
Silty Clayey Sand
P-6
78.8
Silty Clayey Sand
ENGINEERING TESTING
78-008A
David Nitz, Inc. -3- January 24, 1978
As indicated, percolation tests aP-1, P-5 and P-6 met the
percolation requirements, while tests NP-2, P-3, and P-4
indicated values outside the limits for a typical individual
' sanitary sewer system. At that time, in our opinion, it
appeared likely that a suitable drainfield site can be
located on the site further to the west of the drainfield
area site, that was initially investigated.
As you requested, on January 13, four additional percolation
tests, P-7 through I'-10, were performed, approximately 30
' feet further west than the location of P-1 and P-6 and at
slightly higher elevations than those areas tested previously.
Readings of the additional tests were conducted on January
13 with the following results.
Surface Soil At Rate
Test # Elevation Test Depth (mpi)
' P-7 88.4 Clayey Sand 36
P-8 84.2 Clayey Sand 2"'
P-9 80.9 Clayey Sand 45
P-10 84.6 Clayey Sand 60
The average four additional tests, along with the passing
' results of P-1 and P-6, is then 45 mpi.
REMARKS:
In our opinion, a suitable drainfield can be situated imme-
diately to the south and west of the proposed house loca-
tion, with the start of the drainfield at or near the loca-
tion of percolation tests #P-9 and P-10 and extending in a
southeastward manner, following the contours of the slope.
The system designed for Lot 10, Block 1 was based on the
results of percolation tests P-1 and P-6 through P-10, which
indicated an average of 45 mpi. For this system, a total of
295 lineal ''eet of absorptive trench per bedroom would be
required, therefore, the drainfield system consisting of 885
s[. 44a*a4 feet of absorptive trench w.- based on a 3-bedroom
U home for this lot. In order to meet this requirement, six
30-inch wide absorptive trenches 60 feet in length with 7
foot center -to -center spacing should be adequate for this
lot.
It has been our pleasure to be of service to you on this
project. If we can be of further assistance in evaluating
the enclosed data, kindly contact us at your convenience.
I
The content of this rr RtA N DIg SoMents are for the exclusive use of the
we make no representation n assume no responsibihir to any other parties regart
Very truly yours,
irAIZVIL-W LANE BM. nPOF'/wN
NE Qkao CORNER X4aV
,
L07-10,640Ct'Ile
L 90,
P
7,�� LINE
a
- AxEA
i
= �WER' L�!/GiER �i2�n1 G
LOICAr/ay.5 409LWo /A-Arjr PE'MOLA7-10,4 TfsT W049
--..N
BRAUR-
TING
'9- M S911 le0eJnIZ7 ,� rZSram,
L O7 - /O, LCCJ< / ,�ARYr� ►� ,q0P/T,
O�eo n/o,
/- 9- 78 R"sod: 15
own: pMR SoM: � z �
LOG OF BORINGS •_-
PROJECT: 78-008 Soil Borings 6 Percolation Tests DATE: 1/6/78
Lots 8 and 10, Block 1, Farview Addition
Orono, Minnesota SCALE: 1"-4'
BORING: B-1 LOCATION: Lot 10, BORING: LOCATION:
U RF.ELEV• Block 1, See Attached UR ,
77.2 Sketch
ASTM
Depth Descri Lion o Materials D2487 WL DepthDescription of Materials WL
SILTY SAND, fine to
medium -grained, with a SM
trace of fine Gravel,
dark brown to brown,
moist. I
(Coarse Alluvium)
12
17
SILTY CLAYEY SAND, fine
to medium -grained, with a
trace of fine to medium M-SC
Gravel, brown, moist.
(Glacial Till)
SANDY CLAY, brown to
grayish brown, moist to CL
wet.
(Glacial Till) ,
Water level not encountered
10 minutes after completion of
boring.
Water level not encountered
24 hours after completion of
boring.
Bench Mark - Top of iron at N.E
property corner with elevation
assumed - 100.0'.
DESCRIPTIVE TERMINOLOGY
PARTICLE SIZE IDENTIFICATION SOIL INTRUSIONS
'
Bowdon
over 3"
THICKNESS RELATIVE PROPORTIONS
Gravel
lense 0 - 1 /8" with a few 0 - 10%
Cos.
1" - 3
seam 118" - 1" with sane 11 - 20%
'
Medium
1/2" - 1"
loyer 1" - 12" with over 20%
Fine
No. 4 - 1/2"
varved alternating soomss or
Send
lenses of clays and
Coana
No. 4 - No. 10 silts in lake deposit
Modums
No. 10 - No. 40
Fine
No. 40 - No.100
MOISTURE CONTENT ORGANIC CONTENT
Very Fine
No. 100 - No.
200
Sllt
No. 200 - =5 rnm Dry lass than 5% 0-5% non to slightly organic
'
Cloy,
less then A06 mm Moist under optimum moisture 6 - 10% slightly organic
Nbt over optimum moisture 11 - 25% rpnic
Waterbsering saturated send 26 - 65% muck
65+ past
'
RELATIVE DENSITY OF
CONSISTENCY OF PLASTICITY OF SOILS WITH
COHESION LESS SOILS
COHESIVE SOILS LESS THAN 20%CLAY
'
very loose
0 - 4 BPF
very soh 0 - 1 BPF non plastic gritty, cannot thread
loose
5 - 10 BPC
soft 2 - 3 BPF slightly plastic rough to smooth,
medum dense
11 - 30 SPF
rothw soft 4- 5 BPF hard to thread
denea
31 - 60 6PF
medium 6- 8 BPF plastic smooth to waxy.
'
very dense
50+ OFF
rethsr stiff 9 - 12 BPF easy to thread
stiff 13 - 16 BPF
very stiff 17 - 30 BPF
hard 30+ BPF
'
RELATIVE PROPORTIONS
OF GRAVEL
LABORATORY TESTS
'
• tram
0 - 5%
DID Dry Density, pcf OC Organic Content, %
a little
6 - 15%
WD Mt Density, pcf S Percent of Saturation, %
some
16 - 30%
MC Natural Moisture Content, % SG Specific Gravity
and
31 - 50%
LL Uquid Limit, % C Cohesion
'
PL Plastic Limit, % 0 Angle of Internal Friction
PI Plasticity Index, % qu Unconfined Compressive Strength
'
DRILLING NOTES:
Standard penetration test borings were advanced by 2K" or 3%- I.D. hollow -stem augers unless noted other
wise. Jotting water vw used to claw out sugar prior to sampling only whate indicated on logs. Standard
penetration test borings are designated by the prefix "ST" (Split Tube).
Power sugar borings were advanced by 4" or 6" diameter, con tinuous-fhto. solid stem augers. So,l dessificauon
Y'
and strata dept.se are inferred from disturbed sornples sugared to the surface and are therefore somewhat
approximoee. Power sugar borings are designated by the prefix "B".
Hand probings wore advanced manually with a 1 %" diameter probe and an limited to the depth from which
the probe can be manually withdrawn. Hand probings we indicated by the prefix "N".
'
CLASSIFICATION:
Classification on logs is me* by inspection in accordance with the Unified Solis Classification System
two attached chart) using viwal-manual procedures unless noted otherwise.
GROUND WATER:
Observations were me& at the times indicated. Porosity of soil stets, seasonal weather conditions, site
topography. etc., may cause changas in the water levels indicated on the logs.
SAMPLING:
All "I Miles are taken with the standard 2" O. D. split -tube sampler, except where noted. TW indicates thin -
.
well undisturbed samplle.
BPF: Nunsbs. indicate blows par foot recorded in standard penetration test, also known as "N" value The ssmpier
is set 6" into undisturbad soil below the hollow -stem ougw. Driving resistances we then counted for second
and third 6" increments and added to got BPF. Where they differ significantly, they we reported in the
following form - 2/12 for the second and third 6" increments respectively.
WH: WN indketes that sensplet psretrated soil under, weight of hammer and rods alone, driving not required.
NOTE: All tests run in accordance with applicable ASTM standards.
0mun
ENCiNiEERING TESTING
CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES
ASTM DESIGNATION D-2487
Group Typical
Major Divisions Symbols Names Classification Criteria
VWab,
^
c ,'_
�'
4- � N
C
U L
t0
N u
GT
z
q
W o
CM
v
4A
CC
ipt �I N
elf ` f
SP
to lam. WZ
N
SM
qCq
O
'Aa
i A
S��
Sc
N
M 1n
*v o
v� :3 "
v2
J
N
Hell -graded gravels and
Cu - Ddo � D10
Greater than 4
c
gravel -sand mixtures,
little or no fines
�D 1B
0s -�
Between 1 and 3
_ 10 d0
Poorly graded gravels and
gravel -sand mixtures,
Not meeting both criteria for OW
tittle or no fines
N "
Silttyy ggravels, gravel-
ilVsilt
Atterberg limits plot
below "A" line or
Atterberg limits plot -San
y
mixtures
plasticity index
Ping 1ri hatched area
c
less than 4
are borderline
pt
•.� �.�
Clayey gravel:,, gravel_
Atterberg s p o
above "A" line and
classifications re-
qui ring use of dual
i
&
r,
sand -clay mixtures
plasticity index
symbols
o
�
greater than 7
Hell -graded sands and
ou ' D60 D10
Greater than 6
19
d
gravelly sands, little
(Dxn12
a
N a
or no fines
C, - D10 X Od0
Between 1 and 3
st H
Poorly graded sands and
8
gravelly sands, little
Not meeting both criteria for SN
N
or no fines
log
Silty sends, sand -silt
Atterberg limits plot
below "A" line or
Atterberg limits plot-
mixtures
plasticity index less
Ling in hatched area
than 4
are borderline clas-
5 5
Clayey sands, send -clay
er s plot
"
above A line and
sifications requiring
use of symbols
e
N.,
mixtures
plasticit index
�,
I"".,
A "
greater thian
Inorganic silts, rock
flour, silty or clayey
Ic fine sand
Inorganic clays of low to
medium plasticity, yrev- 60
a elly clays, sandy clays,
silty clays, lean clays 50
Organic silts and organic
OL silty clays of low 40
plasticity
Inorganic silts, micaceous30
hig or diatomaceous silts,
elastic silts a PO
Inorganic clays of high w
CIi plasticity, fat clays 1g
4
O
Organic clays of medium
OR to high plasticity
Plaetiaiiv hart
for otwe{fioation of fin•-
gmined .oils and fine fivation
of ooaree-grained soils.
Atterberg limit# plotting in
hatohed area are borderline
ot"sifioatione requiring
we of dual eymbote.
lquation of A-Un4r.,
PI 0.78 (LL-!0
FQb
W
0 10 20 30 40 50 60 70 80 90 100
Liquid limit
Peat, muck end other
Hignly organic soils Pt highly organic soils Vlsuai-manual identification
BRAHH'
ENGINEERING TESTING i
BRAUN ENGINEERING TESTING, INC.
6800 S. COUNTY ROAD 18. P. O. BOX 35108 • MINNEAPOLIS, MINNESOTA 55435
PHONE 612-941.5600
MEMO -LETTER
TO Mr. Scott Abernathy
c/o David Nitz, Inc.
464 Second Street
Excelsior, MN 55331
I- Mr. Abernathy:
DATE March 8, 1978
S,SJECT Prudden Residence
Lot 10, Block 1
Farview Addition
The proposed drainfield for the 4 bedroom house (Prudden Residence) situated on
Lot 10, Block 1 of the Farview Addition should consist of 6 lines, 80 feet in
length with 7-foot center to center spacing. The system lc;cation is as shown
on the attached sketch.
$y 4A14 N72 TT, NP q 9 sd. 1. . ba 3W. Don— T-
— �N
,,o!�7 —
Z- p7" /O , 8LGC �,- /
.p
01tA�NFEELO "
a�
y I PAO' VAiEto > FS7 -
BRAun- L o r�o, e�oc� i ti �,�,ev�Ery Av,,,1
Owo -lo, �t�fiNN,
ENGINEERING TESTING Q D"a:,3/ 7/ 7L Rwiwd: ewn: OM p 4 „ .