Laserfiche WebLink
CITY or ORoNo <br />Municipal Offices <br />Post Office Box 66 <br />Crystal bay, MN 55323-0066 <br />O O\ <br />o , <br />t9kE3HC¢�// <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />Owner: l �l '" I �' 1 Address:_ _7c�!I/,�Yi1)C'�11-�1� <br />Permit #' a: 11 _ v Dates: 4 -�i Contractors: <br />City ordinance number 100 requires that each on -site sewage treatment system in Orono be inspected on a regular basis. <br />The on -site sewage treatment system at the above address has been inspected and appears to fall into tide category <br />checked below. <br />(This is [`) an existing system I I new construction) <br />"CODE SYSTEM'I-A system which meets all the location, design, and construction standards of the current City <br />Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br />without discharging any pollutants into ground or surface waters. <br />"CONFORMING SYSTEM" -A system which does not meet all the location, design, and construction standards of the <br />current City Codes, but was installed according to the code in effect at the time of installation, and which <br />is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br />any pollutants into ground or surface waters. <br />"NON -CONFORMING SYSTEN"-A prohibited system; a system located within a designated 100-year floodplain; any <br />system which may or may not meet all the location, design, and construction standards of the current City <br />Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br />between the distribution device and the limiting soil characteristics. <br />(The limiting soil characteristic KL has or l I has not been identified at this time. i` the limiting soil <br />characteristic has not been identified, this classification may be subject to revision.) <br />i_ <br />Tank inspection indicates: <br />Pumpout not needed at this time. <br />S eds acc l;tion in tanks indicates they %hould be pumped out this year to help prevent fjture robjEtfls. <br />So a cunu ateon in Lanks is at a critical level. Tanks should be pumped�ui a< �oon�asT«� <br />8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br />9 Inspection risers missing -tanks could not be inspected. inspection risers (4" dia. pipe) must be installed in each <br />tank at next pumpout. If tanks have not beer pumped out within the last three years, they should be ptwped <br />out now. <br />10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br />1f tanks have not been pumped out within the last three years, they should be pumped out now. <br />GRAINFIELD CONDITION 0 1.14): 1 <br />Dr field inspection indicates: <br />fly Drainfield is dry, no surfacing evident. <br />T2 Some evidence of surfacing, not criticet yet. <br />13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br />immediately. Repairs must be completed within 90 dayq, <br />14 Drainfield extent and condition unknown. <br />LIMITING SITE FACTORS (slope.setbacks.etc.): j <br />POTENTIAL FOR SYSTEM FAILURE (depends nn soil, --ter table.etc.): [ t%✓t/ <br />COMMENTS: <br />Date of Inspection S66CU 5vstem"Inspector <br />Note: in the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br />property, be advised that this report does not guarantee or certify that an existing system will continue to function <br />properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br />information. <br />This report must be kept on the premises with the system location aged pumping records. <br />WHITE COPY Ingwtors File YELLOW COPY ►lomaowner <br />