Laserfiche WebLink
CITYof ORONO <br />�';b }.� • �` Muokipnl ONkes <br />$Wd Addis: Y318416 =ai:: <br />2750 Kelley Parkway P.O. Box 66 <br />Orono, MN 55356 Crystal Bty, MN 553234M <br />Cwner: Address: 2800 Farview Ln. <br />Permit #'s: 7915 Dates: 5/13/85 Contractors: liestonka Plbq. <br />(This is ( , an existing system I J new construction). <br />SYSTEM COMPL:ANCE (1-3) : 3 <br />1 Code System: Meets or exceeds current City standards in all respects relating to design, <br />construction, and location. Appears to be operating properly. <br />2 Compliant System: Does not meet all current City standards for new construction, but in <br />most respects appears to be designed, located, and constructed in accordance with previous <br />© codes and is functioning properly. <br />Non -Compliant System: System may or may not meet current City standards for design, <br />construction, or location, but is failing to properly treat and dispose of the current <br />input; and any system with less than three feet of vertical separation between the bottom of <br />the drainfield and the saturated soil level. <br />(The saturated soil low I is D41 or is not ( ] identified under this septic system. If the <br />saturated soil lewl is not identified, this classification is subject to revision.) <br />,TANK CONDITION (5-9): 5 <br />5 Pumpout not needed at this time. <br />Solids accumulation in tanks indicates they should be pumped out this year. <br />S•:stem is discharair.a to the surface. Tanks rust bP ­+ � :* wi" ir. 49 hours. <br />8 Inspection risers missing -tanks could not be inspected. If tanks have not been pumped out <br />within three years, they should be p--mped out and risers installed r.^.:. <br />9 Inspection pipe is located over tank baffle -can not measure solids accumulation. If tanks <br />have not been pumped out within three years, they should be pumped out now. <br />10 One or more tanks are cesspools, which means the septic system is non -compliant. <br />(The tank■ are ( ) or are not ( ] water tight or the condition is ()/J unknown. If the tanks <br />are not confirmed to be watertight, this classification is subject to revision.) <br />INFIELD CONDITION (11-14): 11 <br />Drainfield is dry, no surfacing evident. <br />LT'2 Some evidence of surfacing, not critical yet. Repair is not required a: this time. <br />13 Drainfield is saturated and visibly discharging untreated effluent to t<<e surface. Contact <br />the City Inspector immediately. Repair must be completed within 90 days. <br />14 Drainfield extent and condition unknown. <br />POTENTIAL FOR SYSTEM FAILURE: (system age and condition, soils, etc.): sedium <br />C^ '9:NTS: In order to confirm that your septic system meets Minnesota standards, soil borings <br />performed to verify a 3 foot separation between the drainfield and the seasonal water table. <br />separation is 0.6 feet and the system is non -compliant. Repair or replacement of the septic <br />stem is required by 122/31/2009. <br />Date of Inspection -Stytic System Inspector <br />Note: In the event that this inspection report is used to satisfy the requirements for a <br />transfer of property, this report does not guarantee that an existing system will continue to <br />function properly, but indicates the operation of the system under current conditions. <br />Telephone (612) 2494600 • Fax (612) 2494616 <br />