HomeMy WebLinkAbout1990-07-30 On Site Sewage Treatment Inspection Reporti
C» tbt, Nortb Sbore n f
Laki, ,tit rnni,tnrrka
ON -SITE SEWAGE TREATMENT ly
INSPECTION REPORT i0 POST OFFICE BOX 66
ORON 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER )Pr_ r,,V Kdo ADDRESS -22-V &LJI 1ai �C��/tP
PERMIT NO.'S. DATES -� /3 - CONTRACTORS t,1 rnLr �,,�/
� ,6,4
City Ordinance No. k10 requires that each on -vespa treatment system in Orono be inspected on a regular basis. The on -site sewage
treatment system at the above address has been inspec,. J and aipptrers to IN' into the category checked below.
(This is Wan existing system ❑ new construction)
1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to to operating
UJIproperly.
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to he designed.
located, and construc.r.d generally in accordance with previous code:. Syster• appears to t functionin•; properly; no malut
upgrading of the syste. required at this time.
❑ 3 Does not meet current City standards in many respects relating to d"oo.o, construction, <.,; -(,color Apphears to be operating
adequately at this time. but has a relatively high potential for future )blems. No invl^r .,,, rad, ,p of system is required at
this time.
4 System may or maw not meet current City standards for design, construction or location, but is fading to properly treat and
dispose of the current input, and is endangering a water iupply, or is s ource of pollution to surface or groundwaters, or is
creating a safety hoard, or it otherwise creating a public nuisance. Pltasa contact the City Inspector to discuss system repair/
replacement procedures. If dramfield replacement is necessary, soil testing will usually be required, and a design and site plan
rust be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDI TPJJ ` j0 Checked items may require your action)
Tank inspection indicate.
❑ Pumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should be pump-
ed out this year to help prevent future problems.
❑ Sol ..Is accumulation in tanks is at a critical mewl. Tanks
should be pumped out as soon all possible.
❑ System is discharging to sur ace. Tanks must be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection risers missing —tanks could not be inspected.
.s• •Coo,, •sers (4" die. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the let three years, they should be pumped out now.
SITE CHARACTCRISTICS
Limiting Site Factors
❑ Slope
❑ Soil
❑ High water table
❑ Lo- size
❑ Lake, wetland, or ttr . �t
❑ Drainage
4 Inspection pipe is locatvrt directly over tank ',effle, tDoes not
give accurate measurement of solids accumulation.) If tanks
he" not been pumped out with..- the Ira- three years, they
should be pumped out r.ow.
Grainfield inspection indicate.
FA Drainfield is dry. no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
FJ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions *atniteld. Contact the City Inspector
immediately. Repai. , -oust be completed within 80 days.
❑ Drainfiela extent and condition unknown.
Potentiai for System Failure
(defends on soil types, water
table and system condition)
Low
❑ Medium
❑ High
❑ System is causing visible
surface discharge.
COMMENTS -*— vf rr
riLe
- - 7-�' 0
Date of Inspection
Septic System Inspector
Site Capabilities for
Future Expansion
16 Adequate
❑ Fair
LJ Poor
❑ Inadequate
Note. In tta ?Met that this inspection report is used to satisfy the requirements for a mortglegs or other transfer of property, be advised that
d, - ►esrtrt dtst t not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
Oft % . e-sem , cu rent conditions based on rite available information.
This teporl must b_ kept on the premises with system location and pumping recnrds.
WHITF COPY / Inspector's File GOLD COPY / Homeowner