Loading...
HomeMy WebLinkAbout1650 Shadywood Road - Building Plans: ResidentialDRIVEWAY260'-10"124'-2"247'-9"122'-9"10'-11"105'-11"22'-10"55'-0"NPV-016/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NACOVER PAGENEW PV SYSTEM SPECIFICATIONSSYSTEM SIZE:DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACMODULE:(42) JINKO SOLAR JKM425N-54HL4-B (425W)INVERTER:(42) ENPHASE IQ8PLUS-72-2-US (240V)NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM - 17.850 KW DC/12.180 KW AC& ENERGY STORAGE SYSTEM - 10 KWH1650 SHADYWOOD RD, WAYZATA, MN 55391BATTERY:(02) IQBATTERY-5P-1P-NADESIGN CRITERIAROOF SURFACE TYPE: COMPOSITE SHINGLEROOF FRAMING: 2"X4" TRUSS @ 24" OCBUILDING STORY: TWO STORYGROUND SNOW LOAD: 50 PSFWIND SPEED: 109 MPHWIND EXPOSURE: CRISK CATEGORY: IISCALE:1"-30'-0"- PROPERTY LINE- FENCE LINELEGENDSATELLITE MAPAPPLICABLE CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODES:2020 MINNESOTA STATE BUILDING CODE2020 MINNESOTA STATE RESIDENTIAL CODE2020 MINNESOTA STATE FIRE CODE2023 NATIONAL ELECTRICAL CODEAS ADOPTED BY STATE OF MINNESOTAPROPERTY PLANPV-011COVER PAGEPV-01EQUIPMENT DATASHEETS ATTACHEDNOTESSITE PLANELECTRICAL DIAGRAMWARNING LABELSATTACHMENT PLAN & DETAILSINSTALLATION RESOURCESHEET INDEXPV-02PV-03PV-04PV-05PV-06PV-07VICINITY MAPSCOPE OF WORK1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN ANDSPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC & ENERGYSTORAGE SYSTEM. THE CONTRACTOR WILL BE RESPONSIBLEFOR COLLECTION OF EXISTING ONSITE CONDITIONS TO DESIGN,SPECIFY, AND INSTALL THE ROOF-MOUNTED PV SYSTEM ANDENERGY STORAGE SYSTEM DETAILED IN THIS DOCUMENTNOTE:1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSESONLY!2. ALL TESTING SHALL BE PERFORMED BYQUALIFIED PERSONNEL, WITH PROPER PERSONALPROTECTIVE EQUIPMENT3. THE PRODUCTION METER AND AC DISCONNECTSHOULD BE LOCATED TOGETHER IN A READILYACCESSIBLE LOCATION WITHIN 10' OF THE MAINSERVICE METER4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BEPROVIDED FOR THE METERS AND AC DISCONNECTPROJECT NOTES1.1.1 THIS PHOTOVOLTAIC (PV) & ENERGY STORAGE SYSTEMSHALL COMPLY WITH THE RELEVANT YEAR OF THE NATIONALELECTRIC CODE (NEC), ALL MANUFACTURER’S LISTING ANDINSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES ASSPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ)APPLICABLE CODES.1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BEAPPROVED AND THE PV & ENERGY STORAGE SYSTEM MUST BEINSPECTED PRIOR TO OPERATION1.1.3 ALL PV & ENERGY STORAGE SYSTEM COMPONENTS;MODULES, UTILITY-INTERACTIVE INVERTERS, BATTERIES, ANDSOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTEDFOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC ANDOTHER GOVERNING CODES1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCALBUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UVRESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED ASREQUIRED BY THE NEC AND AHJ.(E) HOUSEUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213ROOF ACCESS POINTNEAREST CROSS STREET(~390FT) N SHORE DRSHADYWOOD RDFRONT OF HOUSE (E) GARAGESigned 6/18/2025Reviewed for Code ComplianceNicole PostSES25-0000037-7-25Approved plans must be on sitefor the duration of the project. Plans must be available toinspector.Please call 952-249-4600 toschedule all inspections. Havepermit number and addresswhen calling.Separate Permits RequiredElectrical 134566.16.277.181310112ROOF 4ROOF 2ROOF 3 ROOF 1ROOF 5NTO PVMIN. 3'-0"6"6"6"6"6"6"6"TO IQSC3GPV-026/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NASCALE:1/16" = 1'-0"PLAN VIEW TOTAL ROOF AREA:4678 FT²TOTAL PV ARRAY AREA:882.82 FT²TOTAL % OF ROOF COVERED BY PV:18.87%= FLUE / PLUMBING VENT= MECHANICAL VENTLEGEND44.65"67.79"5(E) UTILITY METER (UNDERGROUND SERVICE)METER #: 99999961MICROINVERTER (1 PER MODULE)2(42) JINKO SOLAR JKM425N-54HL4-B (425W) MODULESWITH ENPHASE IQ8PLUS-72-2-US (240V) UNDER EACHMODULE3JUNCTION BOX; SIZE DETERMINED IN FIELD6(E) METER MAIN PANEL4CONDUIT RUN; SURFACE MOUNTED (ACTUALCONDUIT RUNS TO BE DETERMINED IN FIELD)FIRE SETBACKS36"18"SITE PLANSITE PLANPV-021NO POSITION, DISTANCE AND CLEARANCECONCERNS OF OVERHEAD ELECTRICSERVICE LINES AND/OR OTHER UTILITIES INRELATION TO THE PV PANELSSCALE:N.T.SEQUIP. ELEVATIONPV-022(N) UTILITY OWNED PV PRODUCTION METER(N) BATTERIES13UTILITY DISCONNECT TO BE VISIBLE,LOCKABLE AND LABELED, LOCATED WITHIN10FT OF THE UTILITY METERUTILITY HAS 24/7 UNESCORTED KEYLESSACCESS TO ALL METERS AND DISCONNECTSROOF ACCESSPOINT(N) UTILITY OWNED PV PRODUCTION METERNOTES:1.ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THEPLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS ORDOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION INLOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEADOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.2.STRUCTURES, PATIO COVERS, AND/OR ADDITIONS BUILT WITHOUT PERMITS TO BERESOLVED BY A SEPARATE PERMIT.7(N) UTILITY DISCONNECT 1 OF 2, LOCKABLEVISIBLE-OPEN TYPE & READILY ACCESSIBLE7.1(N) ESS DISCONNECT 2 OF 2, LOCKABLEVISIBLE-OPEN TYPE & READILY ACCESSIBLESLOPE - 40°AZIMUTH - 190°MODULE QTY - 14TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE - COMPOSITE SHINGLEROOF 5SLOPE - 40°AZIMUTH - 190°MODULE QTY - 08TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE- COMPOSITE SHINGLEROOF 4SLOPE- 40°AZIMUTH - 100°MODULE QTY- 10TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE- COMPOSITE SHINGLEROOF 3SLOPE - 40°AZIMUTH - 190°MODULE QTY- 04TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE- COMPOSITE SHINGLEROOF 2SLOPE - 40°AZIMUTH - 100°MODULE QTY - 06TRUSS - 2"X4" @ 24" O.C.SURFACE TYPE- COMPOSITE SHINGLEROOF 1(N) UTILITY ACDISCONNECT 1 OF 2UTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213NEAREST CROSS STREET(~390FT) N SHORE DRSHADYWOOD RDFRONT OF HOUSE BACK OF H O U S E 6.1(E) MAIN DISTRIBUTION PANEL (BACKUP LOAD PANEL)6.2(E) MAIN DISTRIBUTION PANEL(NON-BACKUP LOAD PANEL)12(N) 2x ENPHASE IQ BATTERIES (INSIDE GARAGE)10(N) ENPHASE IQ SYSTEM CONTROLLER 3G8(N) ENPHASE IQ COMBINER BOX 5C11(N) ENPHASE RSD SWITCH9(N) ESS COMBINER PANEL (INSIDE GARAGE)INSIDEGARAGEOUTSIDE WALL(N) UTILITY AC DISCONNECT 2 OF 2(E) UTILITY METER& MAIN PANEL(N) BATTERYCOMBINER(N) ENPHASECOMBINER(N) IQCONTROLLER(N) RSDSWITCHGRADE(E) MAIN DISTRIBUTION PANEL(NON -BACKUP LOAD PANEL)INSIDEBASEMENT(E) MAIN DISTRIBUTIONPANEL (BACKUP LOADPANEL)Signed 6/18/2025 ATTACHMENT PLAN& DETAILS- ATTACHMENT POINTS- RAIL- STRUCTURAL MEMBERLEGENDTYPICAL ATTACHMENT PLAN (PORTRAIT)SCALE: NTSPV-031.0TYPICAL ATTACHMENT PLAN (LANDSCAPE)SCALE: NTSPV-031.1STRUCTURAL MEMBER @ 24" OC4'-0" OC ATTACHMENT SPACINGSTRUCTURAL MEMBER @ 24" OC4'-0" OC ATTACHMENT SPACINGNOTE:1.CONTRACTOR/INSTALLER TO VERIFY COMPATIBILITY OFANY BRANDS OR PRODUCTS SUBSTITUTED OR USED ASALTERNATES WITHIN ANY BRAND-SPECIFIC SYSTEMS.CONTRACTOR SHALL SUPPLY AND PRESENTCERTIFICATES OF COMPATIBILITY TO THE BUILDINGOFFICIAL UPON INSPECTION AS NEEDED.2.REFER TO PV MODULE MANUFACTURER'S INSTALLATIONINSTRUCTIONS FOR RAIL SPACING SPECIFICATIONS(E) COMP SHINGLE ROOFSEE ENLARGED VIEWPV MODULE(E) STRUCTURAL MEMBERMIN. 5/16" x 4-3/4" LAG BOLTINTO STRUCTURAL MEMBERIRONRIDGE FLASHFOOT 2IRONRIDGE AIREDOCKIRONRIDGE AIREINTEGRATEDGROUNDING &MID/END CLAMPPV MODULEIRONRIDGE AIRERAIL(E) STRUCTURAL MEMBERScale: NTSATTACHMENT DETAILPV-032Scale: NTSENLARGED VIEWPV-033PV-036/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NADISTRIBUTED LOAD CALCULATIONSMODULEJINKO SOLAR JKM425N-54HL4-B (425W)MODULE WEIGHT46.30 LBSMODULE DIMENSIONS (L" x W")67.79" x 44.65"TOTAL QTY. OF MODULES42TOTAL WEIGHT OF MODULES1944.60 LBSTYPE OF RACKINGIRONRIDGE AIRE RAIL (AE-A1-170B)TYPE OF ATTACHMENTIRONRIDGE FLASHFOOT 2DISTRIBUTED WEIGHT OF RACKING0.5 PSFTOTAL WEIGHT OF ARRAY2386.01 LBSAREA OF MODULE21.02 SQFT.TOTAL ARRAY AREA882.82 SQFT.DISTRIBUTED LOAD2.70 PSFNOTE: 6" MAXIMUM DISTANCE FROM ROOF SURFACE TO TOP OF PV MODULESUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213Signed 6/18/2025 MGL1L2NLINELOADL1L1L2L2 (N) UTILITY ACDISCONNECT 1 OF 2100A VISIBLE-OPEN TYPE,LOCKABLE, READILYACCESSIBLE ANDNON-FUSIBLE, 240V,NEMA 3R, UL LISTEDGL1L2NGL1L2N(N) PV PRODUCTIONMETER, UTILITY OWNED, NEMA 3R, UL LISTED200A RATED, 1-PHASE,3-WIRE, 120/240VW/ BYPASS HANDLE2TO SYSTEMCONTROLLERAC ~DC ±BATTERY+-L2L1GL2L1G(N) ENPHASEIQBATTERY-5P-1P-NABATTERYAC ~DC ±BATTERY+-L2L1GL2L1G(N) ENPHASEIQBATTERY-5P-1P-NABATTERYGN70A/2P60A/2P100A/2P200A FACTORY WIRINGNFT (AUTOTRANSFORMER)IQ BATTERY(80A MAX)IQ COMBINERGENERATOR(80A MAX)(N) ENPHASE SYSTEM CONTROLLER 3G200A, NEMA 3R, 120/240VN/C3N/C4WIRELESSCOMMSGERIQ COMBINERIQ BATTERY(N) ENPHASERAPIDSHUTDOWNSWITCH(4) #12 AWG THWN-2(1) 3/4" EMT CONDUIT230A/2PG30A/2P(2) #10 AWG THWN-2(1) #10 AWG THWN-2GRND3/4" EMT CONDUITGNE(2) #6 AWG THWN-2(1) #10 AWG THWN-2 GRND3/4" EMT CONDUIT (N) UTILITY ACDISCONNECT 2 OF 2100A VISIBLE-OPEN TYPE,LOCKABLE, READILYACCESSIBLE AND NON-FUSIBLE,240V, NEMA 3R, UL LISTED(N) 100A ESSCOMBINER PANEL,NEMA 3R, ULLISTED, 240V(N) 100A/2P MAINBREAKER, 240V20KWGENERATOR(E) 200A MAINDISTRIBUTION PANEL,W/ (E) 200A/2P MAINBREAKER, 240V(BACKUP LOAD PANEL)(E) 200A/2P MAINBREAKER, 240VMETER #: 9999996L2NL2L1TO UTILITY GRID(E) BI-DIRECTIONAL UTILITYMETER 1-PHASE, 3-W,W/ BYPASS HANDLE, CL320120V/240VMLINELOADGN(E) 400A METERMAIN PANEL, 240VEXISTING GROUNDINGELECTRODE SYSTEM2X (E) 200A/2P MAINBREAKERS, 240VGN(E) 200A MAIN DISTRIBUTIONPANEL, W/ (E) 200A/2P MAINBREAKER, 240V(NON-BACKUP LOAD PANEL)(E) 200A/2P MAINBREAKER, 240VEE3CONSUMPTION CT'sENPHASE CTRL-SC3-NA-01CONTROL CABLEGENERATOR CTGN20A/2PIQ GATEWAY15A/2P(N) ENPHASE COMBINER PANELNEMA 3R, UL LISTED,125A RATEDCELLMODEMWIRELESSCOMMS10A OR 15A BREAKER ISSUITABLE FOR USE20A/2P20A/2P20A/2P#12 AWGENPHASE QCABLE(S)JINKO SOLAR JKM425N-54HL4-B (425W)11 MICROINVERTERS IN STRING 111 MICROINVERTERS IN STRING 210 MICROINVERTERS IN STRING 310 MICROINVERTERS IN STRING 41(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDENPHASE IQ8PLUS-72-2-US (240V)MICROINVERTERS ONE UNDEREACH PANEL (240V)L2L1GL2L1(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDL2L1GL2L1#6 AWG BARE CUROMEX CAN BE USED IN LIEU OF CONDUIT FOR INTERIOR BUILDING AND ATTICRUNS ONLY. DO NOT USE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS.21(ENPHASE X-IQ-AM1-240-5/5C)PV-046/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NAELECTRICALDIAGRAMAMBIENT TEMPERATURE SPECIFICATIONSRECORD LOW TEMP-27°CAMBIENT TEMP (HIGH TEMP 2% AVG.)32°CMINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE7/8"SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODEL #JINKO SOLAR JKM425N-54HL4-B (425W)VMP32.37 VIMP13.13 AVOC38.95 VISC13.58 ATEMP. COEFF. VOC-0.25 %/°CWIRE IDEXPECTEDWIRE TEMP (°C)TEMPDERATE(90 °C)QTY OF CURRENTCARRYINGCONDUCTORSCONDUIT FILLDERATEMINIMUMCONDUIT SIZE(TBD ON SITE)WIRE GAUGE &TYPECONDUCTORAMPACITY @90°C (A)CONDUCTORAMPACITY @75°C (A)REQUIRED CIRCUITCONDUCTOR AMPACITY(A)ADJUSTED CONDUCTORAMPACITY @ 90 °C (A)NEUTRALCONDUCTORSIZE & TYPEGROUND WIRESIZE & TYPE1320.964 /40.83/4''#10 THWN-2403516.6430.72NONE#10 THWN-22320.96211''#4 THWN-2958563.5391.20#4 THWN-2#8 THWN-23320.96212''#3/0 THWN-2225200200.00216.00#3/0 THWN-2#4 THWN-2DESCRIPTIONFORMULARESULTPV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25 = (42 x 1.21)A x 1.2563.53A (SELECTED OCPD = 70A)UTILITY DISCONNECT TO BE LOCATEDWITHIN 10' OF MAIN SERVICE/BILLING METERALL EQUIPMENT RATED FOR SINGLE PHASENOTE:1. THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES ONLY!2. ALL TESTING SHALL BE PERFORMED BY QUALIFIED PERSONNEL, WITH PROPER PERSONALPROTECTIVE EQUIPMENT3. THE PRODUCTION METER AND AC DISCONNECT SHOULD BE LOCATED TOGETHER IN AREADILY ACCESSIBLE LOCATION WITHIN 10' OF THE MAIN SERVICE METER4. 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL XCEL ENERGYEQUIPMENT5. NOTE ALL THE APPLICABLE NEC CODES6. SHOW ALL THE SYSTEMS INCLUDING STORAGE, EXISTING AND NEW (IF APPLICABLE)7. SERVICES <320A WILL USE SELF-CONTAINED MAIN SERVICE METERS. 320A SERVICES MUSTINDICATE WHETHER THE METERING WILL BE SELF-CONTAINED OR TRANSFORMER METERED.ALL SERVICES 400A OR GREATER MUST BE TRANSFORMER METERED8. PRODUCTION METER LOCATED WITHIN 10 FT OF METER9. WIRES LOCATED IN READILY ACCESSIBLE LOCATIONS SHALL BE GUARDED PER NEC690.31(A)10. CONDUIT TO BE UL LISTED FOR WET LOCATIONS AND UV PROTECTED (EX. -EMT,PVC ORRMC) *FMC MAY BE USED IN INDOOR APPLICATIONS WHERE PERMITTED BY NEC ART. 34811. VISIBLE LOCKABLE AND LABELED DISCONNECT IS LOCATED WITHIN 10FT OF METER12. THE INVERTERS ARE UL1741 CERTIFIEDPOC/RPAMICROINVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US (240V)INPUT POWER RANGE235W-440WMIN/MAX START VOLTAGE22V/58VNOMINAL AC VOLTAGE240VMAX CONT. OUTPUT CURRENT1.21AMAX CONT. OUTPUT POWER290WMAX MODULES PER STRING13 (13 MICROINVERTERS)UTILITY HAS 24/7 UNESCORTED KEYLESSACCESS TO ALL METERS AND DISCONNECTSUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213UTILITY PV AC DISCONNECTPLACARD LOCATION: AT UTILITY AC DISCONNECTPHOTOVOLTAICSYSTEM CONNECTEDPLACARD LOCATION: AT MAIN SERVICE PANELNOTES:·MADE OF WEATHERPROOF & DURABLE MATERIALSUCH AS HARD PLASTIC OR METAL·PERMANENTLY ATTACHED TO THE METER SOCKETWITH SCREWS OR RIVETS·YELLOW BACKGROUND WITH BLACK LETTERING·AT LEAST 1-½” HIGH BY 3” WIDE WITH ARIAL BOLD FONTNOTES:·MADE OF WEATHERPROOF & DURABLE MATERIALSUCH AS HARD PLASTIC OR METAL·PERMANENTLY ATTACHED TO UTILITY AC DISCONECTWITH SCREWS OR RIVETS·YELLOW BACKGROUND WITH BLACK LETTERING·AT LEAST 1-½” HIGH BY 3” WIDE WITH ARIAL BOLD FONT NOTESSITE NOTES2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN ACCORDANCEWITH OSHA REGULATIONS.2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE ANDTHIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH STORAGEBATTERIES.2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANYPLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTINGAND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED INACCORDANCE WITH SECTION NEC 110.26.2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, ANDMAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVEDMANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGSERVES TO PROTECT THE BUILDING OR STRUCTURE.EQUIPMENT LOCATIONS2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS INACCORDANCE WITH NEC 110.26.2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BERATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BYNEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C).2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PVMODULES IN ACCORDANCE WITH NEC 690.34.2.2.4 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THEINVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.5 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIEDPERSONNEL IN ACCORDANCE WITH NEC APPLICABLE CODES.2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATEDFOR OUTDOOR USAGE WHEN APPROPRIATE.STRUCTURAL NOTES2.3.1 RACKING SYSTEM & PV ARRAY WILL BE INSTALLED INACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHEREDGE OF THE ARRAY/SUB-ARRAY, IN ACCORDANCE WITH RAILMANUFACTURER’S INSTALLATION PRACTICES.2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'SSPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED& SEALED PER LOCAL REQUIREMENTS.2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BECOMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PERCODE BY A LICENSED CONTRACTOR.2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NOGREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKINGMANUFACTURER OR PROFESSIONAL ENGINEERING GUIDANCE.2.3.5 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILLBE STAGGERED AMONGST THE ROOF FRAMING MEMBERS.WIRING & CONDUIT NOTES2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FORTHEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ONMINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMITUP-SIZING.2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USEDIN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTINGOR LABELING PER NECGROUNDING NOTES2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTEDFOR THEIR PURPOSE, AND GROUNDING DEVICES EXPOSED TOTHE ELEMENTS SHALL BE RATED FOR SUCH USE.2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCEWITH NEC 690.43 AND NEC TABLE 250.122.2.5.3 METAL PARTS OF MODULE FRAMES, MODULE RACKING,AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCEWITH NEC 250.134 AND 250.136(A).2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZEDIN ACCORDANCE WITH NEC 690.45 AND INVERTERMANUFACTURER'S INSTALLATION PRACTICES2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN INMANUFACTURER DOCUMENTATION AND APPROVED BY THEAHJ.2.5.6 THE GROUNDING CONNECTION TO A MODULE SHALL BEARRANGED SUCH THAT THE REMOVAL OF A MODULE DOESNOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHERMODULE.2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG ORLARGER PER NEC 250.1192.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITHNEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTINGSYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDINGELECTRODE SYSTEM PROVIDED IN ACCORDANCE WITH NEC250, NEC 690.47 AND THE AHJ.2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDSDISCONNECTION AND OVERCURRENT PROTECTION NOTES2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THATWHEN THE SWITCH IS OPENED THE CONDUCTORS REMAININGENERGIZED ARE CONNECTED TO THE TERMINALS MARKED“LINE SIDE” (TYPICALLY THE UPPER TERMINALS).2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLEBUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TOREDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS INACCORDANCE WITH 690.122.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDINGTO NEC 690.8, 690.9, AND 240.2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TOA SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S) INACCORDANCE WITH NEC 110.3(B).2.6.6 IF REQUIRED BY THE AHJ, SYSTEM WILL INCLUDEARC-FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH NEC690.11 AND UL1699B.INTERCONNECTION NOTES2.7.1 LOAD SIDE INTERCONNECTION SHALL BE INACCORDANCE WITH NEC 705.12.2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTERCONTINUOUS OUTPUT MAY NOT EXCEED 120 PERCENT OFBUSBAR RATING PER NEC 705.12.2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT AND THE RATING OF THEOVERCURRENT DEVICE PROTECTING THE BUSBAR SHALLNOT EXCEED 120 PERCENT OF THE AMPACITY OF THEBUSBAR, PV DEDICATED BACKFEED BREAKERS MUST BELOCATED OPPOSITE END OF THE BUS FROM THE UTILITYSOURCE OCPD PER NEC 705.12.2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUTCOMBINER PANEL, TOTAL RATING OF ALL OVERCURRENTPROTECTION DEVICES SHALL NOT EXCEED AMPACITY OFBUSBAR. HOWEVER, THE MAIN OVERCURRENT PROTECTIONDEVICE MAY BE EXCLUDED IN ACCORDANCE WITH NEC705.12.2.7.5 FEEDER TAP INTERCONNECTION (LOAD SIDE) INACCORDANCE WITH NEC 705.12.2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCEWITH TO NEC 705.12 WITH SERVICE ENTRANCECONDUCTORS IN ACCORDANCE WITH NEC 230.42.2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWERSOURCES OUTPUT IS EXEMPT FROM ADDITIONALFASTENING PER NEC 705.12.GENERAL NOTESPV-056/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NAUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213 WARNING LABELSLABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECTPER CODE: NEC 690.12(D)(2)LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.12(D)ELECTRICAL SHOCK HAZARDTERMINALS ON THE LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONWARNINGLABEL LOCATION: COMBINER PANEL, AC DISCONNECT,POINT OF INTERCONNECTIONPER CODE: NEC 705.20(7), NEC 690.13(B)WARNINGDUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METERPER CODE: NEC 690.59, 705.30(C)LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METERPER CODE: NEC 690.13(B)POWER SOURCE OUTPUTCONNECTION. DO NOT RELOCATETHIS OVERCURRENT DEVICE.WARNINGLABEL LOCATION: POINT OF INTERCONNECTIONPER CODE: NEC 705.12(B)(2)LABEL LOCATION: POINT OF INTERCONNECTION, COMBINER PANELPER CODE: NEC 705.12(B)(3)TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNINGLABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECTPER CODE: NEC 110.27(C), OSHA 1910.145(f)(7)!!!!THIS EQUIPMENT FED BY MULTIPLESOURCES:TOTAL RATING OF ALL OVERCURRENTDEVICES EXCLUDING MAIN POWERSUPPLY SHALL NOT EXCEEDAMPACITY OF BUSBARWARNING!LABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 705.30(D), NEC 690.59CAUTIONPHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED!SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYDO NOT DISCONNECTUNDER LOADLABEL LOCATION: MAIN SERVICE DISCONNECTPER CODE: NEC 690.15(B) & NEC 690.33(D)(2)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMEMERGENCY CONTACTCEDAR CREEK ENERGY(763) 432-5261LABEL LOCATION: POINT OF INTERCONNECTIONPER CODE: NEC 705.10FOR IMMEDIATE ASSISTANCE CALL 911MAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION: AC DISCONNECTPER CODE: NEC 690.13(B)PV SYSTEMDISCONNECTPHOTOVOLTAIC POWER SOURCELABEL LOCATION: DC CONDUIT, DC JUNCTION BOXPER CODE: NEC 690.31(D)(2)SOLAR PV DC CIRCUITLABEL LOCATION: DC CONDUIT, DC JUNCTION BOXPER CODE: NEC 690.31(D)(2)MULTIPLE SOURCES OF POWER.POWER TO THIS BUILDING IS ALSO SUPPLIEDFROM THE FOLLOWING SOURCES WITHDISCONNECTS LOCATED AS SHOWN:CAUTIONADDRESS: 1650 SHADYWOOD RD, WAYZATA, MN 55391PV-066/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NAPV ARRAYCEDAR CREEK ENERGY1-800-834-3378NPV METERLABEL LOCATION: PV METERLABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTIONPER CODE: NEC 690.54PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OUTPUT CURRENT:50.82 ANOMINAL OPERATING AC VOLTAGE:240 VUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213ENERGYSTORAGESYSTEMDISCONNECTLABEL LOCATION: ESS DISCONNECTPER CODE: NEC 706.15(C)TRI POWER SOURCESSECOND SOURCE ISPHOTOVOLTAIC SYSTEMWARNING!NOMINAL VOLTAGE:MAXIMUM AVAILABLE ISC:PEAK ISC:ISC CLEAR TIME:DATE :ENERGY STORAGE SYSTEM DISCONNECTSYSTEM CONTROLLERRSD SWITCHESS COMBINER PANELSHADYWOOD RD FRONT OF HOUSEMAIN DISTRIBUTION PANEL(BACKUP LOAD PANEL)UTILITY METER & MAINSERVICE PANELMAIN DISTRIBUTION PANEL(NON-BACKUP LOAD PANEL)BATTERIESUTILITY OWNED PVPRODUCTION METERUTILITY DISCONNECTESS DISCONNECTAC COMBINER PANELUTILITY PV AC DISCONNECTPLACARD LOCATION: AT UTILITY AC DISCONNECTPHOTOVOLTAICSYSTEM CONNECTEDPLACARD LOCATION: AT MAIN SERVICE PANELNOTES:·MADE OF WEATHERPROOF & DURABLE MATERIALSUCH AS HARD PLASTIC OR METAL·PERMANENTLY ATTACHED TO THE METER SOCKETWITH SCREWS OR RIVETS·YELLOW BACKGROUND WITH BLACK LETTERING·AT LEAST 1-½” HIGH BY 3” WIDE WITH ARIAL BOLD FONTNOTES:·MADE OF WEATHERPROOF & DURABLE MATERIALSUCH AS HARD PLASTIC OR METAL·PERMANENTLY ATTACHED TO UTILITY AC DISCONECTWITH SCREWS OR RIVETS·YELLOW BACKGROUND WITH BLACK LETTERING·AT LEAST 1-½” HIGH BY 3” WIDE WITH ARIAL BOLD FONT 10'-0" 10'-2" 10'-4"11'-3"ROOF 4ROOF 2ROOF 3 ROOF 1ROOF 5NREFERENCE ONLYINSTALLATIONRESOURCE12345678910ABCDEF**DIMENSIONS ARE 2D (FLAT)PV-076/16/2025SHEET TITLEDRAWN DATEDRAWN BYTSDSHEET NUMBERSYSTEM DETAILSPHONE - (763) 432-5261LIC. NO. - 20638279REVDATEDESCRIPTIONREVISIONSCONTRACTORPROJECT NAME & ADDRESS3155 104TH LN NW, BLAINE,MN 55449CEDAR CREEK ENERGYAPN #: 1711723210014AHJ: STATE OF MINNESOTAUTILITY: XCEL ENERGYJEB MORRISON1650 SHADYWOOD RD,WAYZATA, MN 55391DC SIZE: 17.850 KW DC-(STC)AC SIZE: 12.180 KW ACBATTERY CAPACITY: 10 KWH(42) JINKO SOLAR JKM425N-54HL4-B (425W)(42) ENPHASE IQ8PLUS-72-2-US (240V)(02) IQBATTERY-5P-1P-NAUTILITY METER NO. #: 9999996UTILITY ACCOUNT NO #: 9999996PREMISES #: 999999951CASE #: 06060213Signed 6/18/2025 © 2024 Enphase Energy. All rights reserved. Enphase, the e and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change.IQC-5-5C-DSH-00007-6.0-EN-US-2024-09-30 IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre-wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. The IQ Combiner 5/5C, IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery 5P provide a complete grid-agnostic Enphase Energy System. 5-year limited warranty Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect (CELLMODEM-M1-06-SP-05), only with IQ Combiner 5C • Supports flexible networking: Wi-Fi, Ethernet, or cellular • Provides production metering (revenue grade) and consumption monitoring Easy to install • Mounts to one stud with centered brackets • Supports bottom, back, and side conduit entries • Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80 A total PV branch circuits • Factory installed hold-down kit • Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Reliable • Durable NRTL-certified NEMA type 3R enclosure • 5-year limited warranty • 2-year labor reimbursement program coverage included for IQ Combiner SKUs* • UL1741 Listed X-IQ-AM1-240-5-HDK X-IQ-AM1-240-5C-HDK X-IQ-AM1-240-5 X-IQ-AM1-240-5C IQ Battery 5P Fully integrated AC battery system. Includes six field-replaceable IQ8D-BAT Microinverters. IQ Series Microinverters The high-powered smart grid-ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) simplify the installation process. IQ System Controller 3/3G Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. DATA SHEET *For country-specific warranty information, see the https://enphase.com/installers/resources/warranty page. IQC-5-5C-DSH-00007-6.0-EN-US-2024-09-30 IQ Combiner 5/5C MODEL NUMBER IQ Combiner 5 (X-IQ-AM1-240-5/ X-IQ-AM1-240-5-HDK) IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%), consumption monitoring (±2.5%), and IQ Battery monitoring (±2.5%). Includes a silver solar shield to deflect heat. IQ-AM1-240-5-HDK includes a factory installed hold-down kit compatible with all the circuit breakers mentioned in the Accessories and Replacement Parts section. IQ Combiner 5C (X-IQ-AM1-240-5C / X-IQ-AM1-240-5C-HDK) IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue-grade PV production metering (ANSI C12.20 ±0.5%), consumption monitoring (±2.5%), and IQ Battery monitoring (±2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)¹. Includes a silver solar shield to deflect heat. IQ-AM1-240-5C-HDK includes a factory installed hold-down kit compatible with all the circuit breakers mentioned in the Accessories and Replacement Parts section. WHAT’S IN THE BOX IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System Busbar 80 A busbar with support for one IQ Gateway breaker and  four 20 A breakers for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Pre-wired revenue-grade solid-core CT, accurate up to ±0.5% Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to ±2.5% IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to ±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Enphase Mobile Connect (only with IQ Combiner 5C)4G-based LTE-M1 cellular modem (CELLMODEM-M1-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for the COMMS-KIT-2 board ACCESSORIES AND REPLACEMENT PARTS (NOT INCLUDED, ORDER SEPARATELY) CELLMODEM-M1-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan CELLMODEM-M1-06-AT-05 4G-based LTE-M1 cellular modem with a 5-year AT&T data plan Circuit breakers (off-the-shelf) Supports Eaton BR2XX, Siemens Q2XX, and GE/ABB THQL21XX Series circuit breakers (XX represents 10, 15, 20, 30, 40, 50, or 60). Also supports Eaton BR220B, BR230B, and BR240B circuit breakers compatible with the hold-down kit. Circuit breakers (provided by Enphase)BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P-240V-B (more details in the “Accessories” section) XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 5/5C X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws). Not required for X-IQ-AM1-240-5-HDK/X-IQ-AM1-240-5C-HDK. XA-COMMS2-PCBA-5 Replacement COMMS-KIT-2 printed circuit board (PCB) for IQ Combiner 5/5C ELECTRICAL SPECIFICATIONS Rating 80 A System voltage and frequency 120/240 VAC or 120/208 VAC, 60 Hz Busbar rating 125 A Fault current rating 10 kAIC Maximum continuous current rating (input from PV/ storage)64 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers only (not included) Maximum total branch circuit breaker rating (input)80 A of distributed generation/95 A with IQ Gateway breaker included IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway 1. A plug-and-play industrial-grade cell modem for systems of up to 60 microinverters. Available in the United States, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area. Aire Flush Mount System Strength Tested All components have been evaluated for superior structural performance. PE Certified Pre-stamped engineering letters are available online for most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof structure. Approved Cable Tray Open channel listed to NEMA VE 1, certified to hold PV and DG cables. UL 2703 Listed System Entire system and components meet the latest effective UL 2703 standards. 25-Year Warranty Products are guaranteed to arrive without any impairing defects. Breathe easy with accelerated installations. The Aire® racking system has been carefully engineered to streamline every part of the installation process. We’ve eliminated tiresome hassles, so that you get off the roof and on to your next project faster than ever. Aire® retains the strength and reliability that IronRidge installers depend on. It also takes wire management to the next level with the first (and only) NEC-compliant rail, formally approved and listed as a cable tray. Datasheet ® Works WithAll IronRidgeAttachments Provided inTwo Optimized Rail Sizes © 2024 IronRidge, Inc. All rights reserved. U.S. Patents Pending. Version 1.05 Rails Accessories Datasheet Design Assistant Quickly go from rough layout to fully engineered system. Go to IronRidge.com/design Resources Aire® A2 Rail The tougher, open Aire® rail for higher load capacity. • 8’ spanning capability • Wire management tray • Mill or anodized black Aire® Dock Connects Aire® Rails to attachments with ease. • Clicks on, slides easily • Drops into open slots • Anodized assembly Aire® A1 Rail The lighter, open Aire® rail for standard conditions. • 6’ spanning capability • Wire management tray • Mill or anodized black Aire® Rail Ties Structurally connect and bond Aire® Rails together. • Reinstallable, up to 5x • Internal splice design • No more splice rules Aire® Caps Block entry and provide a finished look to Aire® Rails. • Stay secure on rail ends • Symmetrical, with drain • Cover rough-cut ends Securely bonds MLPE and accessories to Aire® Rails. • Glove-friendly installation • Lays flush in rail channel • Low profile form factor Aire® MLPE Mount Clamps & Grounding Aire® Lock Mids Securely bond between modules to Aire® Rails. • Fits 30-40mm modules • Utilizes UFO® design • Minimal 1/2” gap Aire® Lock Ends Securely bond modules to Aire® Rails along ends. • Fits 30-40mm modules • Easy rail engagement • Clean aesthetics Aire® Lock Stealth® Securely bonds modules to rail ends, entirely hidden. • Angled for easy install • Robust tether leash • Fits most modules Approved for FL Hurricane Zones Aire® has Florida Product Approval. Additional details can be found on the Florida Building Code website. Learn More at bit.ly/florida-aire Attaches rails to tile roofs, with Aire® Dock included. • Works on flat, S, & W tiles • Single-socket installation • Optional deck flashing Aire® All Tile Hook Keeps wiring contained in open Aire® Rail channels. • No module interference • Simple press-in design • Slot for easy removal Aire® Clip Aire® Lug Bonds Aire® Rails to grounding conductors. • Simplified with single bolt • Low-profile form factor • Works with 10-6 AWG One-Tool System - 1/2” Hex-Head Components Cut Sheet AIRE RAIL A1 v1.0 1 170 1.70 0.22 1.40 1.04 1.38 1.17 1) Aire A1 ITEM NO DESCRIPTION QTY IN KIT 1 Aire Rail, A1, Black(or Clear), 170 1 Part Number Description AE-A1-170B AIRE RAIL, A1, BLACK, 170 AE-A1-170M AIRE RAIL, A1, MILL, 170 Part Number Material Value AE-A1-170B 6000-Series Aluminum Black AE-A1-170M 6000-Series Aluminum Clear Cut Sheet AIRE DOCK, BLACK v1.0 2 1 1.39 1 2 1.50 1.01 0.39 0.75 1/2" Head 0.21 1.75 3/8-16 THD 1) CLAW, INSIDE/OUTSIDE 2) CAP SCREW, 3/8-16 X 1.75, CAPTIVE WASHER ITEM NO.DESCRIPTION QTY IN KIT 1 CLAW, INSIDE/OUTSIDE 1 2 CAP SCREW, 3/8-16 X 1.75, CAPTIVE WASHER 1 ITEM NO.DESCRIPTION AE-DOCK-01-B1 AIRE DOCK, BLACK Item No.Material Finish 1 6000 Series Aluminum Mill/Black 2 Nylon Black Property Value Material 300 Series Stainless Steel Finish Clear Tech Brief The Strongest Attachment in Solar IronRidge® FlashFoot2® raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. FlashFoot2® Twist-On Cap FlashFoot2®’s unique Cap design encapsulates the lag bolt and locks into place with a simple twist. The Cap helps FlashFoot2® deliver superior structural strength, by aligning the rail and lag bolt in a concentric load path. Single Socket Size A custom-design lag bolt allows you to install FlashFoot2® with the same 7/16” socket size used on other Flush Mount System components. Three-Tier Water Seal FlashFoot2®’s seal architecture utilizes three layers of protection. An elevated platform diverts water away, while a stack of rugged components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap. FlashFoot2® is the first solar attachment to pass the TAS-100 Wind-Driven Rain Test. Water-Shedding Design An elevated platform diverts water away from the water seal. © 2022 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.01 Tech Brief Installation Features Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. Rounded Corners Makes it easier to handle and insert under the roof shingles. Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. A B C E B C Benefits of Concentric Loading Traditional solar attachments have a horizontal offset between the rail and lag bolt, which introduces leverage on the lag bolt and decreases uplift capacity. FlashFoot2® is the only product to align the rail and lag bolt. This concentric loading design results in a stronger attachment for the system. A ® ® 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Heath J. Harpster, PE, P.Eng office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com May 6, 2025 Revised June 18, 2025 Green Tech Renewables 1299 Farnam Street Suite 300 Omaha, NE 68102 Re: Engineering Services Morrison Residence 1650 Shadywood Road, Wayzata, MN 17.850 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Composite Asphalt Shingles Roof Slopes: 40 degrees Attic Access: Accessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 50 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 109 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2020 Minnesota Residential Code (2018 IRC). This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly . Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non - uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2020 Minnesota Residential Code (2018 IRC), current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Minnesota License No. 57927 Minnesota COA # 972 Signed 6/18/2025