HomeMy WebLinkAbout1977-12-09 Septic System Design ReportAn Expansion of Soil Engineering Services, Inc. BMUR' ENGINEERING TESTING FMINNEAPOLIS/ST. PAUL 6880 S. County Rd. 18, P.O. Box 35108, Mpls., Mn. 55435 / 612-941-5600 J S eRA1INP E, Frnrd,", NORTHERN MINNESOTA 3219 E. 191h Avenue, Hibbing, MN. 55746 / 218.263.8869 P H ANk"" V.c*JiH ow• ""S CENTRAL MINNESOTA 200 Osseo Avenue No., St. Cloud, Mn. 56301 / 612 253 9940 C G KRUSE P E VK*Free Fn,.-v ' December 9, 1977 Mr. Bob Mason Robert }1. Mason, Inc. 14201 Excelsior Boulevard Minnetonka, Minnesota SS343 Re: 77-`26 FOUNDATION INVESTIGATION ' Burnhardt's Single Family Dwelling Lot 3, Block 1 of Lot 49 Auditors Subdivision #203 ' Orono, Minnesota Mr. Mason: ' As per your request, we have recently completed two standard penetration test soil borings at the above referenced location. ' The borings were made to assist in the preparation of the attacr Foundation investigation report. The f .gs encountered rather stiff to stiff silty sandy ' clay ti�l approximately 2 feet below present ground surface. Based on the information obtained from the two soil borings, it is our opinion that the soils present at the site have adequate strength !or support of the footing loads of the proposed buildi:Eg. ' If you have any questions regarding this report or if we may be of further assistance, please contact us at your convenience. ' Very truly yours, BRAUN ENGINEERING "TESTING, INC. eZ ' Ronald A. Shaffer, P.E. Materials i:ngi ecr ' C. G. Kruse, P.E. Vice President - Engineering RAS/CGK:skh ' CONSULTING ENGINEEPS/SOILS AND MATERIALS Test Borings • Foundation Engineering and Recommendations • Inspection or Construction e Material Testing of Sods. Concrete and Budding Components 1 ' December 9, 1977 ' A. INTRODUCTION: A.1. Purpose: The purpose of the investigation was to ' provide soils and groundwater information pertinent to construction of the proposed house. A.2. Scope: Two standard penetration test borings (ST-1 and ST-2) were put down in the northwest and southeast corners of the proposed building area, respectively. The ' boring locations are shown on the attached sketch. A.3. Available Information: You provided us with a loca- tion of the proposed site Juring a phone conversation held with you on November 23, 1977. During this conversation, you also indicated that the four corners of the proposed building area were delineated by steel pins. ' A.4. Borin& Locations: The borings were located based on the verbal information submitted to us, and are shown on the attached sketch. The ground surface elevations at the borings are referenced to the center of the cul-de-sac of Eileen Street, which was assigned datum elevation 100.0. ' A.S. Field Testing $ Sampling: The borings were taken on December "5, l977, wit a truck -mounted core and auger drill in accordance with ASTM D1586 "Penetration Test and Split ' Barrel Sampling of Soils". Using this method, the bore hole is advanced with the hollow -stem auger to the desired test depth. Then a 140-pound hammer falling 30 inches drives a standard 2-inch OD split barrel sampler a total penetration ' of 1� feet below the tip of the hollow -stem auger. The blows for the last foot of penetration are recorded and are an index of soil strength characteristics. Soil samples ' were generally taken at 24-foot increments to the 15-foot depth and at S-foot increments to the termination depth in each of the borings. Use of the hollow -stem auger eliminated the driving of casing and the need for jetting water. A.6. Soil Classification: Mineral soils encountered in the borings were visually amanually classified in the field ' by the crew chief in accordance with ASTM D2487 "Unified Soils Classification System" and ASTM D2488 "Recommended ' Practice for Visual and Manual Description of Soils". A copy of ASTM D2487 is attached. All samples were then returned to the laboratory for verification of the field classifications by a Soils Engineer. Representative samples will remain in this office for a period of 60 days to be available for your examination. A.7. Groundwater Level Measurements: 'fhe bori probed for the presence oT groundwater prior to diate g following withdrawal of the hollow -stem Groun water was not encountered in either boring *ENGINEERING TESTING � I � I I I I I Li 77-226 Mr. Bob Mason -3- December 9, 1977 B. RESULTS: B.1. Lam: Soil strata encountered in the borings, penetra- tion resistances, and water level observations are plotted on the attached Log of Boring sheets. B.2. Soils Encountered: clay which is likely fill beneath the sandy clay to silty sandy clay till was foot of black silty clay Beneath the topsoil to th sandy clay till was again In boring ST-1, 2 feet of sandy was initially encountered. From the termination of the boring, encountered. In boring ST-2, 1 topsoil was initially encountered. e termination of this boring, silty encountered. The standarL' ijunetration values (blows per foot, BPF) deter- mined in t...: course of sampling the soils on site indicate that the consistency of the till materials encountered in both borings ranged from rather stiff to stiff in consistency. C. ANALYSIS $ RECOMMENDATIONS: C.1. Focting Elevations: According to information submitted by Mr. Dan Korba of your firm, you anticipate construction of a split-level style home with tuck -under garage for the property. The footing at the rear of the home will be placed approximately 3h feet below present grade. The footing in front of the structure will be at or near present ground surface. The front half of the proposed house will be placed on from 0 to around S feet of structural fill. We anticipate a maximum soil bearing pressure from the house footings to be 2000 pounds per square foot. Based upon the results of our boring program, and the information obtained from your firm, the soils present at your site can adequately support the footing and structural fill loads without settle- ments detrimental to the proposed structure. C.2. Site Preparation: We recommend that prior to construc- tion of the proposed structural fill and footings, the building area should be stripped of all vegetation, topsoils and existing fill. Compaction of structural fill should be observed and tested by a Soils Engineering firm. We recommend that the fill be compacted to a minimum of 90% of modified Proctor density (ASTM D1s57-70). C.3. Cold Weather Construction: If site grading work and 1 construction of the house ootings is anticipated during cold or inclement weather conditions, we recommend that good winter construction practice be observed. No fill should be placed upon soils which have frozen or contain frozen materials. No soils containing frozen materials should be placed. BRAUR"' ENGINEERING TESTING 77-226 Mr. Bob Mason -4- December 9, 1977 If any concrete is placed, it should be maintained at a temperature in excess of 50 degrees Fahrenheit for a minimum of 48 hours following placement. No concrete should be placed upon frozen soil or soils which contain frozen materials. D. GENERAL REMARKS: The analysis and recommendations submitted in this report are based upon the data obtained from the 2 soil borings performed at the locations indicated on the attached sketch. Variations may occur between these borings, the nature and extent of which may not become evident until construction. If variations are encountered, it will be necessary to make a re-evaluation of the recommendations of this report after performing on -site observations during the construction and noting the characteristics of any variations. Such varia- tions may result in additional foundation costs and it is suggested that a contingency be provided for this purpose. To permit correlation of the soil data obtained to date with the actual soil conditions encountered during construction and to provide continuing professional responsibility for the conformance of the construction to the concepts originally contemplated in this report and to the plans and specifica- tions, it is recommended that we be retained to develop and ' perform the necessary observation and testing program for the excavation and foundation phases of the project. If others perform the recommended observations and/or testing of construction, professional responsibility becomes divided since in doing so, they assume responsibility for verifying that the soil conditions throughout the construction areas ' are similar to those encountered in the borings or recognizing variations which would require a change in recommendations. 11 HRAun ENGINEERING TESTING Z m m a z N ::I = N N O> r bd "rf tiro co oa.+s�H C Or►t7 O. rW > 3ya�a� �a,x 0-4 (A cn � &< a m OH-0 w cn r* W --3 N r•• O o to ► z w 1< 0^ LOG OF BORING HMO ENGINEERIfKi TESTING PROJECT: 77-626 Foundation Investigation Burnhardt's Single Family Dwelling, Lot 3, Block 1 of Lot 49 Auditor's Subdivision #203 Orono Minnesota BORING• ST-2 LOCATION: See Attached Sketch. DATE: 12/5/77 SCALE; 1"-4' Elev. 94.8 Depth 0 ISymbol ASTM D2487 Description of Materials (ASTM: D2488) BPF Teas or Notes 93.8 1 CL SILTY CLAY, black, moist. !,(Topsoil I I I I ! 69.3 20.5 CL SILTY SANDY CLAY, mottled brown with gray, moist, rather stiff to stiff, with a trace of Gravel. (Glacial Till) 9 11 11 12 20 19 21 ! i ! 1 I Termination of Boring Water level not encountered with 24' of hollow -stem auger in ground. Water level not encountered to cave-in depth of 18' immediately after withdrawal of auger. LOG OF BORING emun EHMNEERM G TEaTWO I N PROJECT: 77-626 Foundation Investigation ST-1 LOCATION: Burnhardt's Single Family Swelling, Lot 3, Block 1 of Lot 49 Auditor's Subdivision See Attached Sketch. #203 Orono, Minnesota DATE: 12/5/77 SCALE: 1"-4' Elev. Depth ASTM D2487 Description of Materials BPF Tests or Notes 1.4 0 Symbol (ASTM: D2488) SANDY CLAY, brown, moist. Bench mark: Center of CL (Fill) 1 Eliene Street assigned 89.4 2 datum elevation 100.0' SILTY SANDY CLAY, brown to gray, 16 CL moist, rather stiff to stiff, wit a trace of Gravel. (Glacial Till) 11 i 18 i i 19 20 i a 17 f n i 23 i i 5 22 65.9 25.5 Termination of Boring u u Water level not encountered with 24' of hollow -stem auger in group(. Water level not encountered to cave-in depth of 23' immediately after withdrawal of auger. DESCRIPTIVE TERMINOLOGY PARTICLE SIZE IDENTIFICATION 8"den over 3" OrwN Coarse Illledfum 1/2" — 1" Fine No. 4 — 1 /7' land Co" No. 4 — No. 10 Modum No. 10 — No. 40 Fine No. 40 — No. 100 Vary Flew No. 100 — No. 200 lilt No. 200 — JJ06 mm Clay loss then J306 mm RELATIVE DENSITY OF COHESION LESS SOILS very loon 0 — 4 BPF loon 5 — 10 BPF medium slam 11 — 30 BPF dense 31 — 50 BPF very dense 50+ BPF SOIL INTRUSIONS THICKNE86 let" seam lever 1" — 12" varvad alternating seams or lama of clove and silts in lake deposit MOISTURE CONTENT Dry law than 5% Moist under optimum moisture Mt over optimum moisture fttorboaring saturated send CONSISTENCY OF COHESIVE SOILS very soft 0 — 1 BPF soft 2 -- 3 BPF rather soft 4— 5 BPF msdium 6 — 8 BPF tether stiff 9 — 12 BPF stiff 13 — 16 BPF very stiff 17 — 30 8PF hard 30r 8PF RELATIVE ►ROPORTION$ with a few 0 — 10% with some 11-20% with over 20% ORGANIC CONTENT 0 — 5% non to slightly organic 6 — 10% slightly organic 11 — 25% organic 26 — 65% muck 66* Peet PLASTICITY OF SOILS WITH LESS THAN 20% CLAY non platic gritty, cannot thread slightly plastic rough to smooth, hard to thread plastic smooth to waxy, say to thread RELATIVE PROPORTIONS OF GRAVEL LABORATORY TESTS • tram 0 — 5% DD Dry Density, pcf oC Organic Content, % ' a little 6 — 15% WD yet Density, pcf S Percent of Saturation, % tame /6 — 30% MC Natural Moisture Content, % SG Specific Gravity and 31 — 5011 LL Liquid Limit, % C Cohesion ►L Plastic Limit, % 0 Angle of Internal Friction let Plasticity Index, % qu Unconfined Compressive Strength DRILLING NOTES: Standard penetration tat borings were advanced by 2%" or 3%" I.D. hollow -stem augers unless noted other- ' wise. Jetting weer was used to clean out sugar prior to sampling only where indicated on logs. Standard penetration test borings are designated by the prefix "ST" (Split Tubal. Power auger boring were advanced by 4" or 6" diameter, contin~-Ilite, solid stem augers. Soil classification and strata depths ore inforrod from disturbed samples supred to the surface and are therefore somewhat approxirrew. Power sugar borings are designated by the prefix "B". Hand probings were advanced manually with a 1 %" diernister probe and are limited to the depth from which the probe can be manually withdrawn. Hand probings we Indicated by the prefix "H" ' CLASSIFICATION: Classification on logs is made by inspection in accordance with the Unified Soils Classification System (see attached dart) wing vlsual-manual procedures unless noted otherwise. GROUND WATER: Observations were node at the times Indicted. Porosity of soil strata, seasonal weather conditions, site ' topography, etc., may cause changes in the water levels indicated on the logs. SAMPLING: All sample. we taken with the standard 2" O. D. split -tubs sampler, except where noted. TW indiesta thin - wall undisturbed sample. BPF: Numbers indicate blows per foot reeorded in standard penetration lot, also known as "N" value. The wmpler is set 6" Into undisturbed soil below the hollow -stem super. Driving rosistanca am than counted for second and third 6" increments and added to get 8PF. When they differ significantly, they are reported in the following form — 2/12 for the second and third 6" increments respectively, WH: WH indicates that sampler penetrated soil under weight of hammer and rods alone, driving not required. NOTE: All tests run in accordance with applicable ASTM standards. BMUR" ENGINEERING TESTING CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES ASTM DESIGNATION D-2487 Group Typi cal Major Divisions Symbols Names Classification Criteria 2 w c > O O N M N N N Ln A tr C U. o LnL yWz 4J `N LO v+ u b o. N GW C � A� a, u � GP N GM y N S ~ C CC SW c v� A U N .SP SH � 0�1 �v N li SC N >1 A aJ N r N r L y Av o C as y 4 7 CrLO N J $ N 7 N 0• 4n o z v �d L N O to coO• uEc i ro a � C C +J uL M v L L N 7 y ^ O 4J O �e J C N o rn u, Hignly organic soils Well -graded gravels and Cu = DB0 D10 Greater than 4 0 gravel -sand mixtures, little or no fines 0 CZ = D1 X D2 Between 1 and 3 a o Poorly graded gravels and gravel -sand mixtures, Not meeting both criteria for GW little or no fines o o �" a Silt gravels, gravel- Atterberg limits plot below "A" line or Atterberg limits plot- X 'O Ln En sandysi It mixtures plasticity index ting in hatched area «' �y CM °- less than 4 are borderline Clayey gravels, gravel- Atterberg limits plot above "A" line and classifications re - quirin use of dual •0 sand -clay mixtures plasticity index symbols c 8 1 m greater than 7 Well -graded sands and Cu = D60 I D10 Greater than 6 �+ N gravelly sands, little or no fines Ca = (Dan12 Dso Between 1 and 3 $ r $ N D10 X g Poorly graded sands and gra illy sands, little Not meeting both criteria for SW A o i z 1A or no fines u W u+ i b 0. Silty sands, sand -silt Atterberg limits plot below "A" line or Atterberg limits plot- A d mixtures plasticity index less ting in hatched area ,a than 4 are borderline clas- � � N tterberg m is p o si fi cati ons requiring O Clayey sands, sand -clay above "A" line and use of symbols in r " mixtures plasticity index JiLn greater than 7 Inorganic silts, rock flour, silty or clayey HL fine sand Horgan c c ays of low to medium plasticity, grav- 60 CL elly clays, sandy clays, silty clays, lean clays 50 _ Organic silts and organic OL silty clays of low 40 plasticity30 a Inorganic silts, micaceous W or diatomaceous si Its, elastic silts 20 Inorganic clays of high fat a 1p CH plasticity, clays 7 4 Plasticity chart For classification of fine- grained soils and fine fraction of coarea-grained soils. CH Attarberg lien to plotting in hatched area are borderline otassifications requiring use of dual eymboie. Equation of A -line PI 0.7d (LL-20 CL IZ AE OH )L Organic clays of medium 0 0 10 20 30 40 50 60 70 80 90 100 OH to high plasticity Liquid linri.t Pest, MUCK end otner Pt highly organic soils Visual -manual identification BRAUR ENGINEERING TESTING An Expansion of Soil Engineering Services, Inc. Rmun- TESIING O MINNEAPOLISrST. PAUL 6880 S. County Rd. 18, P.O. Box 35108, Mpls., Mn. W35 / 612-941.5600 J. S. ERAUNP E. Prnrdeir O NORTHERN MINNESOTA 3219 E. 19th Avenue, Hibbing, MN. 55746 / 218.263-8869 P.H. ANDERSON. Vim Pin. Oprariont ❑ CENTRAL MINNESOTA 200 Omo Avenue No., St. Cloud, Mn. 56301 ! 612.253.9940 C G. KRUSE P. E.. V—P— Enprn ,,;g February 6, 1978 Robert F1. Mason, Inc. 14201 Excelsior Boulevard Minnetonka, Minnesota 55343 Re: 77-626 PERCOLATION TESTING Burnhart's Single Family Dwelling Lot 3, Block 1 of Lot 49 Auditor's Subdivision #203 (Riedel Co. Stubb's Bay Add'n.) Orono, Minnesota Mr. Mason: In accordance with your request, we have conducted a total of 30 percolation tests and one power auger boring. The borings and tests were conducted to assist in determining soil absorptivity rates for an individual sanitary system proposed for the above referenced lot. After the initial six tests were taken, the additional tests were taken to find an area on the lot where a drainfield could be placed. It was our opinion that many, if not all, of the locations tested would be suitable if tested during warm weather. The depth of frost this winter is exceptional and appeared to be influencing test results. However, your scheduling did not permit a delay until that time. The boring and percolation tests were conducted at the locations shown on the attached sketch. Pertinent locations and elevations were determined by our field crew, and are based upon the dimensions and elevations of your January 19, 1978 Boundary Survey prepared by Schoell & Madson, Inc. Surface elevations were referenced to top of asphalt on cul- de-sac of Eileen Street at the point where it is indicated on the Boundry Survey to be at elevation 106.5. The percolation tests and borings were drilled with a truck - mounted power auger unit. All operations were conducted in conformance with the City of Orono specifications. CONSULTING ENGINEERS/SOILS AND MATERIALS Test Borings a foundation Engineering and Recommendations* Inspection of Cj�suurpon a Material Testing of Sods. Concrete and Budding Components 77-626 Robert 11. Mason, Inc. -2- February 6, 1978 The soil strata encountered in the boring and results of groundwater observations are shown on the attached Log of Boring sheet. The boring was probed for the presence of groundwater imme- diately upon its completion and again the next day. The presence of groundwater was not observed in the boring during the period of observation. RESULTS: The soil boring encountered 2 feet of dark brown sandy clay topsoil which was frozen to a depth of two feet. From beneath the topsoil to the termination depth of the boring at 20 feet, brown sandy clay till with a trace of gravel was encountered. The results of the percolation tests indicating the soil absorptivities in minutes per inch (mpi) were measured to be the following: Percolation Surface Soil At Absorptivity Test No. Elevation* Test Depth Rate (mpi) 1 97.6 CL-Sandy Clay 60 2 98.0 CL-Sandy Clay ** 3 98.5 CL-Sandy Clay ** 4 98.5 CL-Sandy Clay 80 5 98.0 CL-Sandy Clay 240 6 97.8 CL-Sandy Clay ** 7 96.2 CL-Sandy Clay 80 8 97.0 CL-Sandy Clay 480 9 96.2 CL-Sandy Clay ** 10 96.8 CL-Sandy Clay 240 11 95.0 CL-Sandy Clay 480 12 96.5 CL-Sandy Clay 480 13 94.3 CL-Sandy Clay 240 14 95.2 CL-Sandy Clay ** 15 93.3 CL-Sandy Clay 120 16 93.0 CL-Sandy Clay ** 17 92.3 CL-Sandy Clay 240 18 92.5 CL-Sandy Clay 60 19 96.1 CL-Sandy Clay *** 20 02 0 CL-Sandy Clay *** 21 97.8 CL-Sandy Clay *** 22 99.2 CL-Sandy Clay *** 23 97.9 CL-Sandy Clay *** 24 99.4 CL-Sandy Clay BRAUR'" ENGINEERING TESTING 77-626 Robert Ii. Mason, Inc. -3- February 6, 1978 Percolation Test No. Surface Soil At Elevation* Test Depth Absorptivity Rate (mpi) 2S 102.6 CL-Sandy Clay **** 26 101.0 CL-Sandy Clay **** 27 9S.2 SC -Clayey Sand 60 28 92.2 SC -Clayey Sand 60 29 92.0 SC -Clayey Sand S4 30 92.2 CL-Sandy Llay 480 *Surface elevations were inferred from those elevations which appeared on the January 19th Boundry Survey. **No drop in water level observed. ***Percolation test readings not conducted when water and ice were observed in test holes following 24-hour soaking period. ****Percolation test holes were exploratory in nature and were backfilled when sandy clay soil was encountered to termination depth in the percolation test holes. ANALYSIS: As indicated above, S of the 30 percolation tests conducted on the lot met the specified minimum standard required for a drainfield system. The variability in percolation rates may likely be attributed to 2 factors. There is, of course, the normal variability in soil permeability inherent in all natural glacial deposits. The more dense and/or cohesive the sandy clay and clayey sand tills encountered at test elevation, then the less permeable it will likely be. It is likely that failing test rates have been caused by the presence of ground frost and frozen soil conditions. Although the observable frost depth in the percolation test areas appeared to be approximately IV, temperature measurements conducted during the second series of percolation tests indicated that the soil temperature at the 36-inch depth was 340 F. If the water does not freeze when entering the soil, it would be considerably more viscous, which would reduce its passage through the soil pores RECOMMENDATIONS: We understand that a 3-bedroom house is to he constructed. For a 3-bedroom house, the City ordinance requires 2 septic tanks. Tile first must have a capacity of at least 1000 gallons and the second at least 7S0 gallons. As may be seen from the above tabulation, the initial tests (tests I through 26, excluding P-18) averaged above the Gasumi umun- ENGINEERING TESTING 77-626 Robert H. Mason, Inc. -4- February 6, 1978 required for a suitable drainfield. However, the average of tests P-18 and P-27 through P-29 was slightly less than 60 mpi. At a rate of 60 mpi, a minimum of 330 square feet of absorptive area per bedroom is required. For the proposed 3-bedroom house, the total required absorption area would then be 990 square feet. This can be provided by a total of 5 drain lines, each 80 feet in length, 2'-6" in width, and spaced 7 feet center -to -center. Our recommended design system is illustrated on he attached sketch. Also shown on the sketch are the locations for two future lines. With the addition of these two future lines, the d rain`ield is calculated to be capable of supporting an additional bedroom. Thus, the drainfield as it is pr^sently located has the capacity for future expansion. As an alterate effluent disposal system, we suggest the area immediately east of the proposed drainfield. Although perco- lation tests have not, as yet, been conlucted in this area, we feel that it has potential for effluent disposal, provided a mound system of adequate dimensions and construction is provided. If you have any questions regarding this report, or if we may be of further service on this project, please contact as at your convenience. Very truly yours, BRAUN ENGINEERING TESTING, INC. L� /=ld A. Shaffer, Materials Engineer IL s Vi:e Presiuent - Engineering RAS/CGK:skh 8RAHn_J The content it Ihis repoII ano supporting documents are for th.. exclusive use of the add,essee In the absence of our prmr ordlen app•oval ENGINEERING we make no represenlation and assume no respons,bd-ly to any other parhes regaid,ng such tomlenl I- P ice) P- Z/ N u ♦n zo R2Z �P24 z5 Ikh op-9 ti• c•4 I n op-lo A. E �7 -aU �-/t'✓ "uScU �P. v �. 0 v ti ram, , f P. 1.3 L i ,00 . —q8 • a 11, P Z �a' -- 96 410� 0P 14 +98v ---94 I � a P• .', � � � , 91 90 a 1 10 �K__� •�___ _J S_.. �•` O 1 BRAUn' ENOINEERINC 'ESTING 77 6 Z 6 PFRL vLATIoN TES FIAIG L'wE[.uNC- - 3 -78 NOT TO LOG OF BORINGS PROJECT: 77-626 Percolation 'resting DATE: 2/1/78 Proposed Burnhart Single Family Dwelling SCALE: 1"-4' Lot 3, Blk. 1 of Lot 49 of Auditor's bdivi i P20 Orono Minnesota BORING: PAB-1 LOCATION: See Attached Sketch. BORING: LOCATION: URF.ELEV: SURF. . 98.2 Depth Description 'o'6MterialS D2487 WL Depth Description of Materials WL Fill, SANDY CLAY, with a trace of Gravel, dark CL 2frozenrown.* Fill, SANDY CLAY, with a trace of Gravel, brown, CL 4 SANDY CLAY, with a trace of Gravel, brown, moist. (Glacial Till) CL 20 Water level not encountered with 20' of hollow -stem auger in ground. Water level not encountered to cave-in depth of 20' immediate) after withdrawal of auger. I PARTICLE SIZE IDENTIFICATION DESCRIPTIVE TERMINOLOGY SOIL INTRUSIONS Bouldm Grovel Co•reo Modtum Fine Send Corte Mad um Fine Very Fine Silt Cloy over 3" 1, — 3" 1 /2" — 1' No. 4 — 1 /2" No. 4 — No. 10 No. 10 — No. 40 No. 40 — No. 100 No. 100 — No. 200 No. 200 — .005 mm lop then Am mm RELATIVE DENSITY OF COHESION LESS SOILS THICKNESS Ions@ 0 — 1 /B" seem 1 /B" — 1' layer 1" — 12" verved alternating seems or lenses of clays and silts in lake deposit MOISTURE CONTENT RELATIVE PROPORTIONS with a few 0 — 10% with some 11 —20% with over 20% ORGANIC CONTENT Dry loss then 5% 0-5% non to slightly organic Moist under optimum moisture 6 — 10% slightly organic Wet over optimum moistwo 11 — 25% organic Waterbaring saturated and 26 — 65% muck 65+ post CONSISTENCY OF PLASTICITY OF SOILS WITH COHESIVE SOILS LESS THAN 20% CLAY very loose 0 — 4 BPF very soh 0 — 1 BPF qon plastic gritty, cannot thread tam 5 — 10 BPF soft 2 — 3 BPF slightly plastic rough to smooth, modium dense 11 — 30 BPF rather soft 4— 5 BPF hard to thread d- 31 — 50 SPF medium 6— B BPF plastic smooth to waxy, wry dense 50+ BPF rethw stiff 9 — 12 BPF easy to thread stiff 13 — 16 BPF very stiff 17 — 30 BPF hard 3D+ BPF RELATIVE PROPORTIONS OF GRAVEL LABORATORY TESTS • t►om 0 — 5% DD Dry Density, pcI OC organic Content, % a little 6 — 15% WD Vbt Density, pcf S Percent of Saturation, % some 16 — 30% MC Natural Moisture Content, % SG Specific Gravity end 31 — 50% LL Liquid Limit, % C Cohesion PL Plastic Limit, % B Angle of Internal Friction PI Plasticity Index, % qu Unconfined Compressive Strength DRILLING NOTES: Standard panetration test borings were advanced by 2X" or 3%" I.D. hollow -stem augers unless noted other wise. Jetting water sues used 10 clean out sugar prior to sampling only where indicated on logs. Standard penetration test borings are designated by the prefix "ST" (Split Tube). Power auger borings ware advanced by 4" or 6" diameter, continuous flits, solid stem augurs. Soil classification and strata depths we inferred from disturbed samples sugared to the surface and are therefore somewhat approximess. Power sugar borings are designated by the Prefix "B". Hand probings were advanced manually with a 1'A" diameter probe and are limited to the dep+h from which the Probe can be manually withdrawn. Hand probinge we indicated by the Prefix "H". CLASSIFICATION: Classification on logs is made 121, inspection in accordance with the Unified Sods Classification System Ise@ attached chart) using visual -manual procedures unless noted otherwise. GROUND WATER: Observations veers or" at the times indicated. Porosity of soil strata, seasonal weather conditions, site topography, etc., may cause changes in the water levels indicated on the Icgs. SAMPLING: All sarrsples are to& with the standard 2" O. D. split -tub serspier, except where noted. TW indicates thin - wall undisturbed s: BPF: Number indicate bfuvvs per foot recorded in standard penetration test, also known as "N" value The sampler is set 6" Into undisturbed soil blow the hollow -stem auger. Driving resistances are then counted for second and third 6" increments and added to gat BPF. Where they differ significantly, they are reported in the following form — 2112 for tho second and third 6" increments respectively. WH: WH indicates that sems{•ler penetrated soil under weight of hammer and rode alone, driving not required NOTE: All tests run in accordance with applicable ASTM standards. 0mun, ENGINEERING TESTING CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES ASTM DESIGNATION D-2487 Kajor Divisions Group Typical Symbols Names Well -graded gravels and CW gravel -sand mixtures, N little or no fines w N Poorly graded gravels and o;,.r " M ravel -sand mixtures, oo little or no fines o S11ty gravels, gravel- p� oq N N GN sand=si it mi xtures o ° Clayey gravels, gravel- v $ E " is sand -clay mixtures L Well -graded sands and SW gravelly sands, little or no fines a, L34MPoorly graded sands and b K N {q • SP gravelly sands, little or no fines i9 5 d =o Silty sands, sand -silt 1O'L' N SN mixtures :Q V N yy . C S s Clayey sands, sand -clay SC mixtures N M N, � r N veld 9^ L " co Ln J N .g R� v C d UI 1! a N ,O EVE 15 �g C� L o N _QN � J eA� 14 0 N ` 0. u, Highly organic soils Classification Criteria Cu - De0 / Djo Greater than 4 ^; Cs - ( I DgO Between 1 and 3 N D10 Not meeting both criteria for GW N O �`�' 0) Atterberg limits plot below "A" line or Atterterg limits plot - plasticity index ting in hatched xraa c less than 4 are borderline }t [ ti t -Atterterg limilts plot classifications IsQ above "A" line and quiring use of dual a�a•0 C plasticity index symbols G greater than 7 ' 3 Cu - D60 / D10 Greater than 6 16 16 _� r N Z D Between 1 and 3 d N N gQN D- F Not meeting both criteria for SW a N N 61! N d Atterberg limits plot below "A" line or Atterberg limits plot- plasticity index less Ling in hatched area than 4 are borderline clas- $ DI tie erg limits plot sifications requiring o above "A" line and use of symbols 'A40 plasticit index greater than 7 '; i n Inorganic silts, rock � flour, silty or clayey le fine sand Inorganic clays of low to 60 medium plasticity, grav- CL elly clays, sandy clays, silty clays, lean clays 50 Organic silts and organic OL silty clays of low 40 plasticity Inorganic silts, micaceous 30 M or diatomaceous silts. elastic silts 20 Imo anic cl s of high �r 62 plasticity, fat clays Organic clays of medium OH to high plasticity Plaatioity ohart For olassifioation of fine- grained soils and find fraction of ooarse-grained soils. Cd Atterberg limits Plotting in lntohed area are borderline otassifioations requiring use of dual symbols. Squation of A-li PI - 0.73 (LL-20 CL , �B Od _- At OL I 00 10 20 30 40 50 60 lu tiu `!u 1uu Liquid limit Peat, muck and other Pt highly organic soils Visual -manual identification B�un ENGINEERING TE>sTiNG Ba al4aa, Rom, 4m&41A a 14ddocJa&i, Am ewa"&-rq C"94we" .2335 IV. /4aft4 -#IpAu" 86 Otto G. Bonestroo. P.E. Lawrence F. Feldit•n, P.E. St A4 MLure"& Robert W. Rosen, P.E. Glenn R. Cook, P.E. 551i3 Joseph C. Anderllk, P.E. Keith A. Gordon, P.E. Bradford A. LemberS. P.E. Thomas E. Noyes, P.E. p e: 636-k600 Robert D. FriSeard, P.E. Richard W. Foster, P.E. Richard E. Turner, P.E. James C. Olson, P.E. February 13, 1978 Mr. Tom Jacobs Building Inspector City of Orono Box 66 f Crystal Bay, Mn. 55323 Re: Mason Builders Percolation Tests 3630 Eileen Street Our File No. 139 Dear Mr. Jacobs: Robert G. Schunicht, P.E. Marvin L. Sorvala, l.E. Donald C. BurSordr, P.E. Kenneth R. Metrter, P.E. Charles A. Erickson Leo M. lavrelsky Harlan M. Olson We received a telephone request from Mr. Bob Mason today relative to percolation tests taken at the above address by Braun Engineering Testing. The percolation tests taken approximately a week ago failed to meet minimum requirements for soil absorption systems. It was indicated that freezing temperatures and frost Inay have had an adverse affect on the test results. Mr. Mason requested some kind of interims or contingency approval of the septic system until summer, so he could get a building permit. We checked with Mr. Ron Schaffer of Braun Engineering Testing (941-5600" who reviewed the test procedures. Mr. Schaffer informed us that the soil boring in- dicated sandy clay till material which he said was a marginally accepted soil. Mr. Shaffer also stated that freezing temperatures and frost may possibly had an adverse affect on the test results, but he further stated that "- - - - it is too close to call." "Fie can offer no other conclusive col:aborating opinion of the acceptability of the soils for septic system design. We recommend that no building permit be granted to Mason Builders for the above subject lot until satisfactory evidence of acceptable soils for a eoil absorption system has been submitted. Yours very truly, BON\ EST, ROSE ,ADTDERLIK & ASSOCIATES, INC. Jam" C. Olso JCO:li Telephone 473.7357 CITY Of ORONO Post Office Box 66•Crystal Ray, Minnesota 55323•Municipal Offices On the ]North Shore of Lake Minnetonka March 8, 1978 Jim Olson Bonestroo, Rosene, Anderlik & Associates, Inc. 2335 Hwy 36 St. Paul, MN 55113 Dear Jim: Enclosed is a copy of the perc tests and septic system design layout for Lot 3, Block 1 of Auditor's Subdivision #203. The system is based on a design rate of 60 mpi and 3 bedrooms. My preliminary findings are that the system design appears to conform to code. Please review this report and make a recommendation on approval or disapproval of the system. Thanks! Sincerely, ;%;ako. A.-i Michael P. Gaffron Septic System Inspector MPG:sm Enclosure eea I >\v zy ti� 9�f op-lo PLO ti� is f(P. 3 P- P. 1 �14 4 P 4W ENGINEERING TESTING 0a8 i 1 N W In zo R2Z a Z4 I. -,Puf�'GSEU 1^/ELL I -i— L—_. _-94 92 W V 11.3 , 90 V (a t Y'��L'�.Y! Y: t'•.•yG.l�.4 :. � MtQ:. y]e.v- _ .�. T'^V .. f-Y'•.• �Wt•a !'[:�+::/_s".�L'efaif��yms 7I6Z6 P f>> ATIQN TESTING ^loT 1Q He.�w�.1---- CJ �� • �1�; SS E d30N.d'0IlOOr ROddoo* T/N i� 8c TIddAOlo�id, JNQ Zsds '.Haab .lV*4&" 96 dt Aa4 AIJwsadoIa sa/>s Avow 6d6-*600 March 10, 1978 Mr. Michael P. Gaffron Septic System Inspector City of Orono Box 66 Crystal Bay, Mn. 55323 Re: Septic System Design Review Lot 3, Block 1 Aud. Sub 203 Our File No. 139 Dear Mike, Otto G. Eonestroo, T.E. Robert W. Roune, P.E. de Joseph C. Anrltk, P.E. Bradford A. Lentber;, P.E. Robert D. Prtjaard, P.E. Rickard E. Turner, P.E. James C. Olson, P.E. Lawrence P. Feldslen, P.E. Glenn R. Cook, P.F. Keith A. Gordon, P.E. Thom" E. Noyes, P.E. Richard W. Potter, P.F. Robert G. SchoWells, P.E. Marvin L. Sorvela, P.F. Donald C. Ewpprdt, P.E. Kenneth R. Meister, P.E. Charles A. Erickson Leo M. Pewelsky Harlan M. Olson We have reviewed the proposed on -site sewerage design for the Burnhart Residence at Lot 3, Block 1 of Lot 49, Aud. Sub. #203 submitted by Braun Engineering Testing dated Feb. 6, 1978 and offer the following comments. The drainfield as laid out by Braun Engineering is adequate to meet the code re- quirements for a primary drainfield site. Three of the percolation tests are at 60 mpi (P-18, P-27 and P-28) and one test is at 54 mpi (P-29). There are 5 dis- tribution lines shown each 80 feet in length yielding 1,000 sq.ft. of trench area which is adequate for a three bedroom home. Two future distribution lines are indicated which would yield a trench area of 400 sq.ft. The two future lines indicated on the drawing are not adequate to meet the require- ments of a secondary drainfield site. The remaining percolation tests around the proposed primary site does not indicate adequate soil for expansion. Therefore, we recommend that it be suggested to the Owner to change the design layout somewhat in order to reserve more room for the secondary site area. For example, if the dis- tribution pipes were changed to 4 lines each 100 feet long, there would be addition- al room for expansion to the sides of the drainfield area. In addition, in pro- posed WPC 40, Section H, 5 (page 720) there are recommended reductions in trench area that can be applied as the result of increasing the depth of filter material below the distribution pipes. In conclusion, it is our opinion that the design as submitted meets the require- ments of a primary site, but we recommend that changes or rearrangements in the design be made in order to reserve adequate space for a secondary site in the same general area as the primary site. Yours very Truly, I�pNESTRbO, ROSENB�?ERLIK 6 ASSOCIATES, INC. Jame�Ols n JCO:li / l