HomeMy WebLinkAbout1986-09-04 On Site Sewage Treatment Inspection ReportOn the Nortb Sbore of
ON -SITE SEWAGE TREATMENT
Lake Minnetonka
INSPECTION REPORT POST OFFICE BOX 66
_ '1335 S. Brown Rd.
Cristal Bay, MN 55323
473-7357
'►WNER V1/ 1<= l�afRNffARl ADDRESS J%ZO EtC E'EN SIR[ ET
PERMIT NO.'S. yZ DATES / % - 75 CONTRACTORS EG
City Ordinance No. 210 requires that each on -site sewage treatment system in Or � be inspected on a regular basis. The on -site sewage
treatment system at the abov(, address has been inspected and appears to fall into the categ,)r t checked below.
\ (This is CJ an existing system ❑ new construction)
Meets cr exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating
C1J properly.
El2 Does not meet all cirrent City standards for new construction (1978 Code) but in most respects appear, to be designed.
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this time.
3 Does not meet current City standards in many respects relating to design, construction. or location. Appears to be operating
adequately at this time, but has a relatively high potential fur future problems. No major upgrading of system is required at
this time.
4 System may or may not meet t urrent City standards for (esign, construction or location, but is failing to properly treat and
dispose of the current ;nput, and is endangering a water suW.)Iv, or is a source of pollution to surface or groundwater%, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedu,es. If drainfield replacement is necessary, Soil testing will usually be rseuired, and a design and site plan
roust be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION.( m Checked items may require your action)
Tank inspection indicates:
PumpOut not needed at this time.
�J SWids accumulation in tanks indicates they should be pump•
ed out this year to help prevent future problems.
Cl Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as ponible.
❑ System is discharging to surface. Tanks must be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection risers missing —tanks could not be inspect-1
Inspection risen (4" dtii. pipe) must he installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
SITE CHARACTERISTICS
limiting Site Factors
`fl Slope
C Soil
❑ High water table
Lot size
❑ Lake, wet':-,, or stream
C Dreinayr
COMMENTS
❑ Inspection pipe is located directly over tank baffle. (Does not
give accurate measurement of solids accumulation ) If tanks
have not been pumped out within the last thre7 years, they
should be pumped out now.
Drainfield inspection indicates:
❑ Drainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to dratnfield. Contact the City Inspector
immediately. Repair% must be completed within 10 days.
Drainfield extent and condition unknown.
/01(',z.(i.07E-/) Hk£A 11MI
Potential for System Failure
(depen•k r i soil types, water
-table, and system condition)
'0 Low
❑ Medium
❑ High
❑ System is causing visible
surface discharge.
Date of Inspection Septic System Inspector
Site Capabilities for
Future Expansion
❑ Adequate
_-E] Fair
❑ Poor
❑ Inadequate
Note In the ever that this msoection report is used to satisfy the requirement' for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but i% merely an opinion of the adequacy
Of the systein rider current conditions based on the available information.
This report must be kept on the premises with system location and pumping records
WHITE COPY ! In:pectni's File GOLD CU'r i' ' ":�meuwner