Loading...
HomeMy WebLinkAbout1979-12-05 Letter, Recommended Alterations to PlanTelephone 473-7357 CITY of ORONO Yost Office Box 66•Crystal Bay, Minnesota 55323•Municipal Offices On the North Shore of Lake Minnetonka December 5, 1979 Mr. Sid Reber= Rebers Construction 3525 Webster Avenue Minneapolis, MN 55416 RE: Proposed Jackson Residence, Edgewood Hills Road Dear Mr. Rebers: We are in receipt of a set of plans and application for permit for the proposed Edge Jackson residence on Edgewood Hills Road as of today. In a cursory review of the information submitted, I find a few discrepancies which must be resolved before we can issue a building permit. 1) Side Setback - proposed 27' - 30' required. A readjustment of the house location may take care of this. 2) Septic System - The information submitted is merely a preliminary report based on two perc tests and one boring. ►r.. must have a total of at least 6 perc tests (and 3 borings) showing both a primary and alternate drainfield site as well as a system design. Based on the preliminary perc test, a usable area of approximately 6,000 - 8,000 sq. ft. should be delineated and preserved for drainfield use. I also note that from the topographic sketch some steep slopes occur on the lot and should be avoided for proper A rainfield functioning. Please see the attached sheet showing wha-c remains to be submitted. If you have any questions, please call. Sincerely, Michael P. Ga fron Septic System Inspector MPG:3j Enclosure TO: Jeanne Mabusth, Zoning Administrator FROM: Michael P. Gaffron, Septic System Inspector DATE: December 18, 1979 SUBJECT: Proposed Septic System Approval Freda Keith - Edgewood Hills Road I have reviewed the soil testing and septic system proposal for the proposed Edge Jackson home on Edgewood Hills Road. Although at first glance the lot appears too steep for a drainfield system, some natural terracing occurs where drainfields will be acceptable. Ample area can be preserved for present and future drainfields on the lot. The soil borings and perc tests indicate a standard system should work satisfactorily on the lot. The septic system for the Freda Keith residence at 1045 Edgewood Hills Road (adjacent to lot in question) was inspected today and appears to be functioning properly. Ample room exists on the property for use as future drainfield. Although the Jackson lot and the existing Keith residence are both less than two acres, the position of the houses on the lots leaves much room for drainfield. I would recommend approval of the 1.6 acre Jackson lot as a building site.