HomeMy WebLinkAbout1979-08-09 Septic System Design ReportBRAUR.'"
ENGINEERING TESTING
WUNEAPOLIS/ST. PAUL 6800 S. County Rd. 18, P.O. Box 35108, Mph., MN / 612.941.5600
NORTHERN MINNESOTA 3219 E. 191h Avenue, Hibbing, MN 55746
'CENTRAL MINNESOTA 1520 - 24th Ave. N., P.O. Box 189, St. Cloud, MN 56301
DULUTH/SUPERIOR 5431 Airpark Blvd., Duluth, MN 55811
SOUTHERN MINNESOTA 40 - 16th St. S.E., Rochester, MN 55901
August 9, 1979
Mr. Sid Rebers
Rebers Construction
3525 Webster Ave.
Mpls., MN
Mr. Rebers:
J S. INAUN LE. P..abn
►H. ANDERSON. vo /m Gbww,ar
C.G xA USE ►E.. V—P- Eti.—"
DA HAUSLER ►.E,�.or,..
Re: 79-429 PRELIMINARY SOIL BORING
6 PERCOLATION TESTS
Lot adjacent to 1045
Edgewood Hill Road
Orono, MN
As you requested, we have recently completed a preliminary soil
probe and two percolation tests to aid in evaluating soil, soil
absorptivity, and groundwater conditions relevant to the poten-
tial design of an individual sanitary system to be situated at
the above referenced lot.
At this time, we understand that it is your desire only to eva-
luate conditions for a potential system rather than completing
the entire series of soil borings and six percolation tests
required for City of Orono approval. Boring and test locations
are shown on the attached sketch.
INVESTIGATION METHODS:
' Due to the existing flower garden situates: in the proposed drain -
field area, you requested that we not use our power drilling
equipment for this exploratory study.
On August 2, 1979, our crew performed a hand auger probe, put
down to the 6-foot depth in lieu of a boring. The hand auger
probe was used to retrieve samples from varying depths as the
' probe was being advanced, in screw fashion, into the ground.
Strata depths are considered somewhat apptoximate using this
apr ;-ich. As soil samples were being retrieved, they were imme-
diite.Ly visually and manually classified by the crew chief in
accordance with the ASTM D2487 "Unified Soils Classification
CONSULTING ENGINEERS/SOILS AND MATERIALS
Test Borings • Foundation Engineenng and Recommendations • Inspection of Construction • Material Testinr. )f Sods. Concrete and Building Components
79-429
' Rebers Construction -2- August 9, 1979
' Syste i and ASTM D2488 "Recommended Practice for Visual and Manual
Desckiption of Soils". A .few representative samples were then
returne, to our office for verification of field classifications
by a Soils Engineer. Those samples will remain in this office
for a period of 60 days to be available for your examination.
The hand auger probe was checked for the presence of groundwater
with the use of electrical water level detector. The initial
probing was completed immediately after removal of the auger and
' once again at the time of percolation test readings, conducted
approximately 24 hours later.
The percolation tests were run in 6-inch diameter holes drilled
to an apnrnxirate depth of 36 inches, in accordance with proce-
dures re nded by the City of Orono. In accordance with those
procedur. -e bottom and sides of the holes were scratched with
a knife b. -c remove any smeared soil surface and to provide a
natural sc-terface into which othe water may percolate. Two
inches o. c - sand was then placed in the bottom of the holes
to prevert uring. The holes were then carefully filled with
clear water to a minimum of 12 inches over the top of the sand
and allowed to soak overnight with the percolation test being
conducted the following day.
RESULTS:
The attached log contains the results of the probe and the water
level information.
Soil encountered, Ln the probe include approximately 1 foot of
black silty sand topsoil underlain by a clayey sand gla-ial till
to the 6-foot termination depth of the probe. Groundwater was
not encountered in the probe at the time of its completion nor
when rechecked approximately 24 hours liter.
The percolation tests indicated soil absorptivities in minutes
per inch (mpi) as follows:
Test Soil at Test Depth
P-1 Clayey Sand, brown
P-? Clayey Sand, with
layers of fine to
medium sand, bro%
REMARKS:
Rate (mpi)
15
10
BRAUR
ENGINEERING TELTING
79-429
Rebers Construction
-3- August 9, 1979
Results of the percolation tests indicate the area testes' will be
quite suitable for drainfield development. The results of the
two percolation tests average out to 12.5 minutes per inch (mpi)
which is well below the necessary 60 mpi rate required for drain -
field development. It should be noted, however, that these
results are unusually low for a clayey sand. The layers of sand
encountered in P-2 may be the reason for the low rates. Future
tests over a wider area may find higher rates.
GENERAL:
We appreciate this opportunity to be of service to you on this
project. If you have any further questions regarding these data
or, kindly contact us at your convenience.
Very truly yours,
BRAUN ENGINEERING TESTING, INC.
"Vennis M. Rietschel
Engineering Geologist
,e-,&.
C. G. Kruse, P. .
Vice President - Engineering
DMR/CGK:jn
The content of this report and supportmq doeume IT, ate lot the e.c ius,.c .,%e or v e addressee In Ihe,Dse,, a of our pr,or -I apotovaI
we make no teptesenlation And assume no reWo•t S. o,hty to any other patties rtca,mnq such conic it
HRAun'
ENGINEERING TESTING
I
MOWN"%
AucEA �ec
it , - iwL., r,&.,JW i -*;, —.1. %1- 1�v4a. , "
LOG OF BORINGS
r
JECT: 79-429 PRELIMINARY SOIL BORING 6 PERC TESTS
Adjacent to 1045 Edgewood Hill Drive
Orono, Minnesota
BORING: HA-1 LOCATION: 10RING:
See Attached Sketch SMECEV:
NOT OBTAINED
Depth Descri Lion o oriais D248,WL Depth Da criG
1 SILTY SAND, black, moist. SM
CLAYEY SAND, fine to SC
medium -grained, brown,
muist.
6
(Glacial Till)
Water level not encountered
wheci probing boring 10 minutes
after completion of boring.
Water level not encountered
when probing boring 24 hours
after completior f boring.
d
DATE: 8/3/79
SCALE: 1"-4'
LOCATION:
of Motor is (s
DESCRIPTIVE TERMINOLOGY
PARTICLE RIZE IDENTIFICATION
sosus,+rs
over 3"
Gnewel
Coma
1' - 3"
Il"um
1 /2" - I"
Firsts
No. 4 - 1 /2"
tend
Cosies
No. 4 -No. 10
Medum
NO. 10 - NO. 40
Fine
No. 40 - No. 100
Wry Fine
No. 100 - No. 200
silt
No. 200 - =5 min
Qey
lea than AN mm
RELATIVE DENSITY OF
COHESION LESS SOILS
very loon 0- 4 5PF
loose L - 10 sPF
medium deism 11 - 30 IIPF
dense 31 - 50 GPF
very defies W MF
RELATIVE Petit' 7RT13AIS
SOIL INTRUSIONS
THICKNEst
Mnsm 0 - 1 /8"
urns 1I8" - t'
Myer V, - 12"
waived alternating seems or
lenese of cMye and
silts in Oaks deposit
MOISTURE CONTENT
Dry less then 5%
Montt under optimum moisture
Mt over optimum moisture
Watrsrbearing saturated send
CONSISTENCY OF
COHESIVE SOILS
very soft
0 - 1 IIPF
soft
2 - 3 BPF
rather soft
4- 5 9PF
medium
6- 8 IIPF
rather stiff
9 - 12 BPF
stiff
13 - 16 BPF
vary still
17 - 30 BPF
hard
30+ BPF
RELATIVE ►MCIPORTIONS
with a few 0 - 10%
with soma 11-20%
with over 20%
ORGANIC CONTENT
0 - 6%
non to slightly organic
6 - 10%
slightly organic
11 - 25%
organic
26 - 65%
muck
66+
out
PLASTICITY OF SOILS WITH
LESS THAN 20% CLAY
non plastic gritty, cannot thread
slightly plastic rough to smooth,
hard to thread
plastic smooth to waxy.
easy to thread
OF ?L
LABORATORY TESTS
a tray o - 5%
DD Dry Density, pcf OC Organic Content, %
a little 6 - 15%
WD Wat Density, prof S Percent of Saturation, %
some 16 - 30%
MC Natural Moisture Content, % SG Specific Grw,Iw,
and 31 - 60%
LL Liquid Limn, % C Cohesion
PL Mastic Limwt, It, 0 Angle of Internal Faction
/1 Plasticity Index, % qu Unennfined Cowitwessive Strength
DRILLING NOTES:
Standard penetration tint borings were advanced by 25G" or 3%" I.D. hollow -stem augers unless noted other-
wiss. Jetting wear was used to ck,*n out sugar prior to sampling only where indicated on Iogs. Standard
peretraion last borings are designated by the prefi: "ST" (Split Tubal.
Power sugar boringe wen advanced by 4" or 6" diameter, continuous -flits. solid stem augers. Soil classification
and strata depths are infarred fr m disturbed samples sugared to the surface and are therefore sormewhst
pproximass. Power sugar boring are designated by the prefix "B"
Hand probing -"re adwertoed manually wwth a 1 h" diameter probe end are limited to the depth from which
the probe can be manually withdrawn. Hand probing. are indicated by the prefix 'H".
CLASSIFICATION:
Classification on Im is., by inspection in accordance with the Unified Sods Classification System
(see attached chrtl using visual manual procedures unless noted otherwise.
GROUND WATER:
Observations wen nude at the limn indicated. Porosity of soil Strata, seasonal weather conditions. site
topography, etc., mnay, own changes in the water levels indicated on the log.
SAMPLING:
All setnptss are taken with the standard 2" O. D. split -tube smmpla, except when noted. TW indicates Stun
wall undisturbed srnwit.
BPF:
Nu lint indcase blows per foot recorded in strtdrd penetration tat, also known as "N" value The sampler
is set 6" into ter -disturbed soil below the hollow -stem auger. Driving resistances are then counted for second
and third 6" increments and added to get BPF. Mlhere they differ significantly, they two reported to the
following form - 2/12 for the second and third 6" increments respectively,
WH:
WH indieasas that sampler penetrated soil under weight of hammer and rods alone, driving not required
NOTE:
All "Pate run in accordance with applicable ASTM standards.
omen
ENGINEERING TESTING
CLASSIFICATION OF SOILS FOR ENGINEERING PURPOSES
ASTM DESIGNATION D-2487
Group Typical
Major Divisions Symbols Nerves Classification Criteria
v O
0
4 u
s
'"
u c
�' c
p�
+
•si
L,su.
N G
Ev
0
u 4n
'
LA
N
tN N
L- «1
U Y � OJ
N 9 0
r
Cro
N
Ln
J
N
N
'
N
A
N
�a+,On
,�
,
at
Hignly organic soils
Well -graded gravels and
Cu - De0 " D]0
Greater than 4
0
^9
GW
gravel -send mixtures,
little or no fines
0D+ �7!
Ca - p10e
Between 1 and 3
N
Poorly graded gravels ane
0
ravel -sand mixtures.
Not meeting both criteria for GW
little or no fines
N'_
Silty gravels, gravel-
Atterber, limits plot
below «A� line or
Atterberg limits plot-
us to
+ +" '9
CM
san s It mixtures
plasticity index
ting in hatched area
c
c
less than 4
are borderline
d$•`t
Clayey gravels, gravel-
arberg limits p o
above «A« line and
classifications re -
quiring use of dual
• +
GC
sand -clay mixtures
plasticity index
symbols
c
greater than 7
Well -graded sands and
Cu - De0 I D10
Greater than 6
a
w
SW
gravelly sands, little
(D 2
or no fines
Ca - DI-
Between 1 and 3
B
g N
N
' j
Poorly graded sands and
SP
gravelly sands, little
Not eting both criteria for SW
me
A
N
or no fines
6A 2
Silty sands, sand -silt
Atterbe limits plot
below «A� line or
Atterberg limits plot-
a` N
N d
Sw
mixtures
plasticity index less
tiny in hatched area
than 4
-are borderline clas-
$�
SC
Clayey sands, sand -clay
tte er s plot
above A and
sifications requiring
use of symbols
c
'" r•8
N
mixtures
yline
greeters thann¢x
Inorganic silts, rock
flour, silty or clayey
AM fine sand
norgen c clays of low to
60
med' m plasticity, grav-
a elly clays, sandy clays,
silty clays, lean clays
50
Organic silts and organic
OL silty clays of low
40
plasticity
Inorganic silts, micaceous
30
M or diatomaceous silts,
elastic silts
20
Inorganic clays of high
p,
M plasticity. fat clays
Organic clays of medium
q9 to high plasticity
Ptastioity short
For otassifieation of fine-
-pained soils and fine fraotion
of coarse -grained voile.
Atterberg limits Plotting in
hatohed area are borderline
olassifioatione requiring
we of dual symbols.
lquation of A-li
PI - 0. 78 (LL-20
,
AB
GBf
Al
4
00
10 20 30 40 50 60 70 80 90 100
Liquid limit
Peat, muck and other
Pt highly organic soils Visual -manual identification
BRAHR'