HomeMy WebLinkAbout1987-09-04 On Site Sewage Treatment Inspection ReportOn the Nortb Sbore of
Lake Minneto►►ka
ON -SITE SEWAGE TREATMENT
INSPECTION REPORT POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER Fcf2d a C, _ <oe, uc� ADDRESS ) Qyc� {gl /:, h5gJ
PERMIT NO.'S. l a� DATES 8' oZ(d - �21t? CONTRACTORSMi-r-Obij
City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regufer basis. The onU-site sewage
treatment systc n at the above address has been inspected and appears to fall into the category checked below.
(This is X an ?xisting system ❑ new c instruction)
}� 1 Meet% or exceeds current City standards in oil respet is relating to design, car.truction, and location. Appears to be operating
G]I properly.
2 Does not meet all current City standards for new construction i1978 Code) but in rnost respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly; no major
upgrading of the system is required at this Time.
3 Doe• not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, bu! nos a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may or may not meet current City standards for design, construct, an or location, but is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a sour-e of pollution to surface or groundwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please r )ntact the City Inspector to discuss system repair/
replacement procedures. if drainfield replacement is necessary, soil testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a pe lit before work is started.
SYSTEM CONDITION (L-A Checked items may require your action)
Tank inspection indicates.
JR Pumpout not needed at this time.
❑ Solids et, -umulation in tanks indicates they should be pump•
ad out this year to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumpers out as soon as possible.
❑ System is discharging to surface. Tanks must be pumped
within 48 hours to eliminate surface discharge.
❑ Inspection risers missing -tanks could .tot be inspected.
Inspection risers (4" rhis. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
SITE CHARACTERISTICS
FJ Inspection pipe is located airectly over tank baffle. (Does not
give accuratti measurement of solids accumulation.) If tanks
have not been pumped out within the last three veers, they
should be pumped out now.
Drainfield inspection indicates:
IR Drainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to drain'++Id. Contact the City Inspector
immediate'y. Repairs must be completed within 90 days.
Drainfield •+xtent and condition unknown.
Limiting Site Factors
Potential for System Failure
Site Capabilities for
❑ Slope
(depends on soil types, water
Future Expansion
❑ soil
table, and system condition)
Adequate
❑ High water table
IR Low
Fair
❑ Lot site
❑ Medium
❑ Poor
❑ Lake, wetland, or stream
❑ High
t.i, Inadequate
❑ Drainage
❑ System is causing visible
surface discharge.
COMMENTS — -- -- ----
-- ----
-- 5J A -87 -- -
Date of Inspection Septic S inspector
Note In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to fun,:tton properly, but is Merely an opinion of tote aclo-quacy
of the system under current conditions based on the available information.
This report must be kept on the urr- bei with system location and pumping recordt
WHITE COPY Inspei for s I ;Ir GOLD COPY Flomeown-