Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2555 Fox Street - Septic Compliance
24910 Territorial Road, Rogers, Minnesota 55374 • 763-428-4489 info@endeseptic.com • www.endeseptic.com ______________________________________________________________________________ Property Address: 2555 Fox St Orono, MN 55391 A septic compliance inspection was completed on the system, and the system is Compliant according to the MPCA codes for Chapter 7080 and local codes for the City of Wayzata in Hennepin County. The system the following attributes: Date Building Built: 1992 Building Use: Residential-5 bedroom Date Septic Built: Septic Updated in 2012 Septic Tanks: 3-1250-gallon septic tanks. Manhole covers to grade, inlet and outlet baffles in place. Pump Tank: 1250-gallon tank, manhole cover to grade. ½ hp pump, on/off float and alarm float in working condition during inspection. Soil Treatment: 2-10’x75’ at-grade systems. At-grades were installed uphill from eachother. Balancing valves were located to adjust squirt heights between each at-grade lateral. Holding Tank- Comments; Squirt heights were tested and found to be off. At-grade is reacting in a fashion that shows perforation plugging is occurring. A lateral cleaning should be completed and squirt height adjustments changed. Ende Septic Service, LLC, has been hired to perform a compliance inspection of your ISTS for compliance with local ordinances pursuant to Minn. State. Sec. 155.55 (2010). The compliance inspection covers only the criteria required by Minn. Stat. Sec. 155.55, Subd. 5a (2010 and Minn. R. 7080.1500 (2011). A Compliance inspection is a snapshot in time of your septic system and does not warrant the condition or longevity of your septic system. Ende Septic Service, LLC, disclaims any use of the compliance inspection beyond determining SSTS compliance pursuant to Minn. Stat. Sec. 155.55 (2010). https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 1 of 4 Compliance inspection report form Existing Subsurface Sewage Treatment System (SSTS) Doc Type: Compliance and Enforcement Instructions: Inspector must submit completed form to Local Governmental Unit (LGU) and system owner within 15 days of final determination of compliance or noncompliance. Instructions for filling out this form are located on the Minnesota Pollution Control Agency (MPCA) website at https://www.pca.state.mn.us/sites/default/files/wq-wwists4-31a.pdf. Property information Local tracking number: Parcel ID# or Sec/Twp/Range: 0411723440002 Reason for Inspection Property Transfer Local regulatory authority info: City of Orono Property address: 2555 Fox St Orono, MN 55391 Owner/representative: Joe Delano and Cindy Chen-Owners Tyler Walen-Realtor Owner’s phone: 701-789-0438 Brief system description: 3-1250 gallon septic tanks and a 1250 gallon pump tank. Effluent pumped to 2-10'x75' atgrade rockbeds. System status System status on date (mm/dd/yyyy): 10/14/2025 Compliant – Certificate of compliance* Noncompliant – Notice of noncompliance (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note: Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. Systems failing to protect ground water must be upgraded, replaced, or use discontinued within the time required by local ordinance. An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or under section 145A.04 subdivision 8. Reason(s) for noncompliance (check all applicable) Impact on public health (Compliance component #1) – Imminent threat to public health and safety Tank integrity (Compliance component #2) – Failing to protect groundwater Other Compliance Conditions (Compliance component #3) – Imminent threat to public health and safety Other Compliance Conditions (Compliance component #3) – Failing to protect groundwater System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) – Failing to protect groundwater Soil separation (Compliance component #5) – Failing to protect groundwater Operating permit/monitoring plan requirements (Compliance component #4) – Noncompliant - local ordinance applies Comments or recommendations Both at-grades have balancing valves to ensure proper gpd flowing to both systems. The at-grade is reacting like it has plugged perforations. A lateral cleaning service must be completed soon. Certification I hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form. Business name: Ende Septic Service Certification number: C9206 Inspector signature: Tristan Ende License number: L2654 (This document has been electronically signed) Phone: 763-428-4489 Necessary or locally required supporting documentation (must be attached) Soil observation logs System/As-Built Locally required forms Tank Integrity Assessment Operating Permit Other information (list): https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 2 of 4 Property Address: 2555 Fox St Orono, MN 55391 Business Name: Ende Septic Service Date: 10/14/2025 1. Impact on public health – Compliance component #1 of 5 Compliance criteria: Attached supporting documentation: System discharges sewage to the ground surface Yes* No Other: photos Not applicable System discharges sewage to drain tile or surface waters. Yes* No System causes sewage backup into dwelling or establishment. Yes* No Any “yes” answer above indicates the system is an imminent threat to public health and safety. Describe verification methods and results: Checked for backup issues-nothing found. Visually inspected the top of the at-grade to check for surfacing. nothing found. Opened rockbed inspection pipes f-probed top of at-grade to check for ponding- nothing found. 2. Tank integrity – Compliance component #2 of 5 Compliance criteria: Attached supporting documentation: System consists of a seepage pit, cesspool, drywell, leaching pit, or other pit? Yes* No Empty tank(s) viewed by inspector Name of maintenance business: Ende Septic Service Sewage tank(s) leak below their designed operating depth? Yes* No License number of maintenance business: L2654 Date of maintenance: 10/14/2025 Existing tank integrity assessment (Attach) If yes, which sewage tank(s) leaks: Date of maintenance (mm/dd/yyyy): (must be within three years) Any “yes” answer above indicates the system is failing to protect groundwater. (See form instructions to ensure assessment complies with Minn. R. 7082.0700 subp. 4 B (1)) Tank is Noncompliant (pumping not necessary – explain below) Other: Describe verification methods and results: Tanks pumped through manhole covers and visually inspected while empty. Tanks are precast and have manholes cover to grade. Pump and floats in working condition during inspection. https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 3 of 4 Property Address: 2555 Fox St Orono, MN 55391 Business Name: Ende Septic Service Date: 10/14/2025 3. Other compliance conditions – Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? Yes* No Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? Yes* No Unknown *Yes to 3a or 3b - System is an imminent threat to public health and safety. 3c. System is non-protective of ground water for other conditions as determined by inspector? Yes* No 3d. System not abandoned in accordance with Minn. R. 7080.2500? Yes* No *Yes to 3c or 3d - System is failing to protect groundwater. Describe verification methods and results: 3A. Manhole covers checked for damage and securement- nothing of concern found. 3B. Pump tank electrical checked. nothing of concern found 3c. No other issues of noncompliance. 3d. n/a Attached supporting documentation: Not applicable photos 4. Operating permit and nitrogen BMP* – Compliance component #4 of 5 Not applicable Is the system operated under an Operating Permit? Yes No If “yes”, A below is required Is the system required to employ a Nitrogen BMP specified in the system design? Yes No If “yes”, B below is required BMP = Best Management Practice(s) specified in the system design If the answer to both questions is “no”, this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? Yes No b. Is the required nitrogen BMP in place and properly functioning? Yes No Any “no” answer indicates noncompliance. Describe verification methods and results: Attached supporting documentation: Operating permit (Attach) / https://www.pca.state.mn.us • 651-296-6300 • 800-657-3864 • Use your preferred relay service • Available in alternative formats wq-wwists4-31b • 4/28/2021 Page 4 of 4 Property Address: 2555 Fox St Orono, MN 55391 Business Name: Ende Septic Service Date: 10/14/2025 5. Soil separation – Compliance component #5 of 5 Date of installation 07/16/2012 Unknown (mm/dd/yyyy) Shoreland/Wellhead protection/Food beverage lodging? Yes No Attached supporting documentation: Soil observation logs completed for the report Two previous verifications of required vertical separation Not applicable (No soil treatment area) Compliance criteria (select one): 5a. For systems built prior to April 1, 1996, and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Drainfield has at least a two-foot vertical separation distance from periodically saturated soil or bedrock. Yes No* 5b. Non-performance systems built April 1, 1996, or later or for non- performance systems located in Shoreland or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.* Yes No* Indicate depths or elevations A. Bottom of distribution media 0"" B. Periodically saturated soil/bedrock 36" C. System separation 36" D. Required compliance separation* 30.6"+ *May be reduced up to 15 percent if allowed by Local Ordinance. 5c. “Experimental”, “Other”, or “Performance” systems built under pre-2008 Rules; Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (Intermediate Inspector License required ≤ 2,500 gallons per day; Advanced Inspector License required > 2,500 gallons per day) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. Yes No* *Any “no” answer above indicates the system is failing to protect groundwater. Describe verification methods and results: Soil borings taken on North side of at-grade between the upslope of both at-grades. Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (ITPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the system is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food, beverage, and lodging establishments as defined in law. Field Copy Soil Profile Description Last updated: 1/8/10 Observation # : Equipment : Limiting Layer Vegetation : Weather : Observation # : 1 Horizon Depth Shape Grade Consistence 0-13 blocky weak friable 13-19 blocky moderate friable 19-31 blocky moderate friable 31-36 blocky moderate friable Observation # : 2 Horizon Depth Shape Grade Consistence 0-12 blocky weak friable 12 to 17 blocky moderate friable 17-26 blocky moderate friable 26-36 blocky moderate friable clay loam North of At-grade Elevation: South of At-grade Elevation: clay loam 10YR5/4 loam 10YR3/2 Soil Texture Matrix Color Redox features clay loam 10YR3/3 10YR4/4 sb1 bucket auger 36" grassy Sunny Company: Address: LGU: Soil: 10/14/2025 2555 Fox St Orono, MN 55391 City of Orono Ende Septic Service Date Completed : loam 10YR3/2 clay loam 10YR3/3 Till clay loam 10YR4/4 clay loam 10YR5/4 Matrix ColorSoil Texture Redox features Ende Septic Service, LLC, 24910 Territorial Road, Rogers, MN 55374 Phone: (763) 428-4489 info@endeseptic.com www.endeseptic.com Hennepin County Natural Resources Map Date: 10/15/2025 Comments: This data (i) is furnished 'AS IS' with no representation as to completeness or accuracy; (ii) is furnished with no warranty of any kind; and (iii) is not suitable for legal, engineering or surveying purposes. Hennepin County shall not be liable for any damage, injury or loss resulting from this data. COPYRIGHT © HENNEPIN COUNTY 2025 Legend PID: 0411723440002 Address: 2555 Fox St, Orono 55391 Owner: Cindy Delano & Joseph Delano Acres: 20.05 ¯1:600 3-1250 Gallon Septic Tanks 1250 Gallon Pump Tank Supply Line 2-10'x75' At-Grade Systems sb1 sb2 Photo; Top of Pump Tank Showing electrical box and septic pump PHOTO; INSIDE VALVE BOX SHOWING LATERAL BALANCING VALVE PHOTO; TOP OF AT- GRADE #1 FACING SOUTH PHOTO; EAST END OF AT-GRADE #2 SHOWING SQUIRT TEST