Laserfiche WebLink
On the North Shore of <br />take Minnetonka <br />ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT POST OFFICE BOX 66 <br />1335 S. Brown Rd. ' <br />Crystal Bay, MN 55323 <br />473.7357 <br />i <br />f <br />OWNER MEMOS 4 XfA!r34r+et RudfCG ADDRESS 34-Z4 East Lxlke. st <br />PERMIT NO.'S. 7041 DATES �O 74 - 3 — CONTRACTORS 7 aakn 07 'Iti� <br />City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a regular bil" The on -site sewage <br />treatment system at the a� addrefa has been inspected and appears to fall into the category checked below. <br />(This is an existing system ❑ new construction) <br />Meets or exceeds current City standards in all respects relating to design co,.struct,on, and location. Appears to be operating <br />properly <br />El2 Does nut meet all current City standards for new construction (1978 Code) but in most respects appears to be deigned, <br />located, and constructed generally in accordance with previous codes. Sv.tem appears to he functicning property; no major <br />upgrading of the system is required at this time. <br />El3 Does not mew current City standards in many respects relating to design, construction, or lucation. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at <br />this time. <br />4 System may or may not meet current City standards for design, construction or 1-.cation, but is fading to properly treat and <br />dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or g.oundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nwsance. Pleam contact the City Inspector to discuss system repairs <br />replacement procedures If drainfield replacement is necessary, soil testing will usually be required, and a design and site plan <br />must be submitted for review. Your- u,.. -tor must obtain a permit before work is started <br />SYSTEM CONDITION ( Ir Checked items may require your action) <br />Tank inspection u„ t,, ates <br />❑ Purnotxir not needed at this time. <br />❑ Solids accumulation in tanks indicates they should be pump- <br />ed out ihi+ year to help prevent funire problems. <br />❑ Solids accumulation in tanks is at a critical level. Tans.s <br />should be pumped out as soon as possible. <br />❑ System is discharging to surface. Tanks mutt be pumped <br />mthin 48 hours to eliminate surface discharge. <br />❑ Inspection risers missing —tanks could not be inspected. <br />Inspection risers (4" dia. pipe) must be installed in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped cat now. <br />Inspection <br />pipe is located over tank baffle. IDoes riot <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />should be pumped out now. <br />Dr infield inspection indicates <br />�Drainfield is dry, no surfacing e. �ictent. <br />[[[[[[]]]]]] aorne evidence Of surfacing, not critical yet. <br />❑ Drainfield is saturated and visibly discharging untreated <br />effluent t0 Me surface, This condition may require replace• <br />ment or additions to drainheld. Contec, the City Inspector <br />immediately. Repairs must be completed within 90 days. <br />❑ Drainfield extent and condition unknown, <br />SITE CHARACTERISTICS <br />Limitirg Site Factors <br />Potential for System Failure <br />Site Capabilities for <br />❑ Slope <br />idepends on soil types, water <br />Future Fxpansior <br />Soil <br />table„arsd system condiuonl <br />L! ArMquore <br />High water table <br />Low <br />❑ Fair <br />Lot size <br />❑ Medium <br />❑ Poor <br />Lake, wetland, or stream <br />❑ High <br />❑ Inadequate <br />❑ Drainage <br />❑ System is causing visible <br />surface discharge <br />/�1 <br />CCMMYI//EE{/./NyTS:: t/�1,'1L r0_Is,Q,Z5 ShDLAJ <br />VOJr- Stit.� �1LL1� !�i_I Lr,e1J7!ltaiif <br />t/� <br />L�L_Ll,8 �.)1_ r(0 ri,144,f 2d <br />7]iaup/a q nau a Us_rn • .� <br />LlelasL/ <br />- <br />9fits of Inspeetkm Septic System Impactor <br />Now In the evens that this inspection report is Lind to satisfy the ronuirernents for a mortgage or other traMfa of property, bit advised M1N <br />this repot t does not guarantee or certify that an existing system will cont.nue to function properly, but is merely an opinion of Me adagmwv <br />of the system under current conditions based on the available information. <br />rh,s report m,.,t be kept on the premises with system location and pumping records. <br />WHf1F. COP' ! Inspector's File GOLD COPY i Homeowner <br />L_ <br />