My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1981-05-04 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
E
>
Eastlake Street
>
3424 Eastlake Street - 05-117-23-13-0044
>
Septic
>
1981-05-04 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/16/2025 9:50:01 AM
Creation date
10/16/2025 9:43:17 AM
Metadata
Fields
Template:
x Address Old
House Number
3424
Street Name
Eastlake
Street Type
Street
Address
3424 Eastlake Street
PIN
0511723130044
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TO: Jeanne A. Mubusth, Zoning Administrator <br />FROH: Michael P. Gaffron, Septic System Inspector <br />DATE: May 4, 1981 <br />SUBJECT: Septic Testing, McCleary Property, 3445 Bayside Road <br />#589 <br />I have reviewed the site evaluation report submitted by <br />Carl Borg on behalf of Mr. McCleary, and wish to make <br />the following comments: <br />1. Testing was done the beginning of April. In nearly <br />all. holes the water table vas round to be at a depth <br />of 1.0-1.8 feet below the surface. This coupled with <br />my bori:.•js in December 1979 indicate that the water - <br />table fluctuates, but is probablv at least 1 foot <br />below the surface dur_ng most of the year in the areas <br />tested. (which are the highest portions of the property) <br />2. Percolation tests were taken at a depth of 15", and <br />where water table was below the hole an average percolation <br />rate of 17 minutes per inch was found. The black silty <br />organic clays of the site are underlain by seams of <br />sand and gray silty clay. <br />3. Cased on the above findings, it seems that the major <br />limiting site factor is the water table, which nor -ally <br />for a mound system would have to be at least 2 to 3 <br />feet below the surface as a minimum. The design <br />proposed by the applicants site evaluator includes <br />adding a layer of fill from the site over the natural <br />surface to increase the depth to water table to 2 feet <br />or more. This appears to be the best method as long <br />as A) the material used for fill is essentially the <br />same organic silty clay as that on the drainfield <br />site; and B) the fill material and existing soil are <br />Plowed or scarified to minimize any layering effect <br />that could occur, which might create a permeability <br />boundary and cause lateral seepage. <br />4. The proposal incorporates . separate rockbed for each <br />house within a single sand mound/berm. This method <br />will allow for separation of each residence's effluent <br />and will help to determine liability should system <br />failure ever occur. <br />S. The existing well/hand pump system should be properly <br />filled and sealed prior to any construction on the <br />site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.