Laserfiche WebLink
ON -SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />On the Nortb Shone of <br />Lake Minnetonka <br />POST OFFICE BOX 66 <br />1335 S. Brown Rd. <br />Crystal Bay, MN 55323 <br />473-7357 <br />OWNER L � �5 ADDRESS � L:Z? OF 1— <br />PERMIT NO.'S. - DATES '-' CONTRACTORS = —. <br />City Ordinance No. 210 requires that each onsiss town" treotrnent system ir. Jrono be inspected on a rgwlar basis. The onsite sewage <br />reatrrsent system at the above address has been Inspected and appears to fail Into .he category chocked below. <br />IThis is a an existing system ❑ new construction) <br />C1 Moots or exceeds current City standards in all respects relating to design, construction, end location. Appears to be operating <br />properly <br />2 Does not most all curtain C_ standards for new construction (1978 Code) but in most respects appears to be desigrseu, <br />located, and constructed ganemily in axadanea with previous codes. System appears to be fi•rtctioning properly. no inajor <br />upgrading of the system is required at this time. <br />�j 3 Does not meet current City standards in many respects relating to do-, dot, construction, or 'cation Appears to be operating <br />11 �� sid wiitNv at this time, but has a relatively high potential for future y,oblems. No major upgrading of system is required at <br />this tims <br />4 system may or may not most current City standards for design, construction or location, but is failing to properly treat and <br />d.spwa of it.e current input, and % endangering a water rupply, or is a source of pollution to surface or groundwaters, or is <br />seating a safety, harerd, or is otherwise creating • „ubiie nuisance. Plains contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, "nil testing will usually be requited, a d a design and site plan <br />must btu submitted for review. Your contractor must o:rtain a permit before work is started. <br />SYSTEM CONDITION 1 jZ Checked itenM may require your action) <br />Tank inspection indicate: <br />-)Oe— KIliumpout not nesd"o at this time. <br />❑ Solids accumulation in tanks indicalas they should be pump- <br />ed out this Vow to help prev!nt future problems. <br />❑ Solids accumulation in tanks is at a critical level. Tanks <br />should be pumped out n soon as possible. <br />❑ System is discharging to surface. Tanks must be pumped <br />within 48 hours to Niminat ii surface discharge. <br />❑ Inspection risers mining —tanks could not be inspected. <br />Inspection risers (4" die. pipe) must be installed in sad- tank <br />of next pumpout, if tanks haw not been pumped uut within <br />the last three yearn, they should be pumped out now. <br />SITE CHARACTERISTICS <br />Limiting Site Factors <br />❑ Slope <br />L✓ High water table <br />❑ Lot site <br />❑ Lake, ovetlanrt, n, st yam <br />U Drainage <br />OOdMMEN I$: <br />Date of Inspection <br />❑ Inspection pope is located directly over tank baffle. (Don not <br />give accurate measurement of solids accumulation.) If tanks <br />here not basin pumped out within the last three yeas, they <br />should be pumps:) out now. <br />Dra.nfleld inspection indicates: <br />U Drainfield is dry, no surfacing evident. <br />U Some srAdence of surfacing, not critical yet. <br />❑ Drainfiold is saturated and visibly diuf.orging untreated <br />effluent to the surface. This condition may require replace- <br />ment or additions to drainfield. Contact the City Inspwtnr <br />imnsedietely. Repairs must be completed within 90 rlsys. <br />59 Drainfield extent nod condition unknown. <br />Potential for System failure <br />Idepends on soil types, water <br />tatJo, and system condition) <br />❑ Low <br />❑ Medium <br />❑ High <br />❑ System is causing visible <br />surface discharge <br />Site Ca"Wittes for <br />Future Exponsiors <br />❑ Adequate <br />❑ Fair <br />❑ Poor <br />❑ inside ivate <br />Note I th event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of pronorty. he advised that <br />this repo,, does not guarentee or certify that an existing system writ continue to function ptopeilV, but is merely an opinion of the adequacy <br />of the sysrem under current conditions bated on the available information <br />This report must be lies, Nn the premises with system location and pumping recorrh <br />wiim. c.nPY ; Inspector's File GOLD COPY ' Norrteowne, <br />