HomeMy WebLinkAbout1990-07-31 On Site Sewage Treatment Inspection ReportON -SITE SEWAGE TREATMENT INSPECTION REPORT On the Nortb Sbore of Lake Minnetonka POST OFFICE BOX 66 1335 S. Brown Rd Crystal Bay, MN 55323 A73-7357 OWNER ADDRESS -S 1 lea? �' ___ PERMIT NO.'S. -- DATES CONTRACTORS - Lity Oi dinance No. 210 requires that each on -site sewage treatment system in Orono be inspected on a reguler basis. The on -site saevege treatment system at the above addrttss has then inspected and appears to fall ,nto the category checked below. (This is �d an c crating system ❑ new construction) 1 Masts or exceeds current City standards in all respect. elating to design, construction, and iocation. Appears to be operating Properly . 2 Doss not meet all current City standrrds for new construction 11978 Code) but in most respects appears to be designed, located, end constructed generally in accordance with previous codes. Syster, appear to be functioning properly; no major upgrading of the system is required at this time. R`3 Does not meet current City stet derds in many respects relating to design, construction, or location. Appears to be operating adequately at this time, but he; a re' 'ively high potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet cu, ent Goy standards for design, construction or location, but is failing to properly treat and dispose of the may input, and is endangering a water supply, or is #1 source of pollutirn to surface of groundrreters, or is creating a safety hazard, or is otherwise creating a public nuisance. Pleats contact the City Inspector to discuss sys,•- , repe,r/ replacement procedures. It drainfield rsplacemant is necessary, sod testing will usually be required, and is design and site plan must be submitted fnr review. Your contractor must obtain a permit before work is started. SYSTEM CONDITION ( [Z Checkeo items may require your action) Tank inwectlon indicates: Pumpout not needed at this time. Solids accumulation in tanks indicates they should be pump - ad out this year to help prevent future problarns. ❑ Solids accumulation in tanks is at a critical level, Tanks should be pumped out as soon as ;xmible. ❑ Systerr is discharging to surface. Tanks most be pumped within 48 hours to eliminate surface discharge. ❑ Inspection risers missing --tanks could not be inspected. Inspection risers (4" din, pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped out now. SITE CHARACTERISTICS. Limiting Site Fa, •ors ❑ Slope Cl Soil ❑ High water table ❑ Lot size ❑ Lake, wetland or stream ❑ Drainage COMMENTS 11 inspection F,;,v is located directly over tank baffle. (Does not give accurate measurement of _,lids accumulation.) If tanks have not been pumper! not n the last :hree years, they should be pumped Drarnfield inspection indict 5- Drainfield is dry, no surfacing evic ant. ❑ Se -nr evidence of surfacing, not critic., at. O Ornrr.ield is saturated and visibly discharging untreatec: effluent to the surface. This condition may require replace- ment or additions to drainfield. Contact the Ct,.y Inspector immediately. Repairs must be completed within 90 days. ❑ Drarnfield extent and condition unknown. Potential for Syst^m Failure Site capabditie. (depandt on soil types, water Future F xpens- table, and system condition) ❑ Adequate ❑ Low C7 r au U Medium Poor ❑ High Inadec) ite ❑ System is causing visible surface discharge Onto of inspection optic System Inspector Note. In the et._ni that the. nspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that this report dos not guarantee or certify that an existing system will continue to function properly, but is merely rn opinion of the edequicy of the system under current conditions tiesed can the available information. This report must be kept on the, premises with system location and pumping records WHITE COPY / Inspector's File GOLD COP` I Homeowner