HomeMy WebLinkAbout2690 Rainey Road - Septic ComplianceMIN{TROL AGENCY s� POLLUTION Compliance inspection report form 520 Lafayette Road North Existing Subsurface Sewage Treatment System (SSTS) 5t. Paul, MN 55155-4194 Doc Type Compliance and Enforcement Instructions: Ins tar c or sU iM,i( COMDdcted iorrn to Local Gove n .,, ntnl Unit (LC IJ) an(_i _y ston-i o J� r € � iti7iii 3 =final c1 tc , mirra�uon or or nont ,.: m oliance. Instructions for filling out this form are located on the Minnesota Pollution Control Agency (MPCA) website at li ; Property information Local tracking number: Parcel ID# or Sec/Twp/Range: 0411723430016 Reason for Inspection Sale of property Local regulatory authority info: City of Orono - 612-249-4600 Property address: 2690 Rainey Road Orono MN Owner/representative: Jody Smith Owner's phone: 952-250-2934 Brief system description: (2) 1000 Gallon Pre -cast Septic tanks (1) 1000 Gallon Pre -cast Pump tank, with a 1Ox 50 foot rockbed with 12 inches of sand under rockbed. System status System status on date (mm/dd/yyyy): 9/23/2025 ❑ Compliant — Certificate of compliance- (Valid for 3 years from report date unless evidence of an imminent threat to public health or safety requiring removal and abatement under section 145A.04, subdivision 8 is discovered or a shorter time frame exists in Local Ordinance.) *Note: Compliance indicates conformance with Minn. R. 7080.1500 as of system status date above and does not guarantee future performance. ® Noncompliant — Notice of noncompliance Systems failing to protect ground water must be upgraded. replaced, or use discontinued within the time required by local ordinance. An imminent threat to public health and safety (iTPHS) must be upgraded, replaced, or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance or under section 145A. 04 subdivision 8. Reason(s) for noncompliance (check all applicable) ❑ Impact on public health (Compliance component #1) — Imminent threat to public health and safety ® Tank integrity (Compliance component #2) — Failing to protect groundwater ❑ Other Compliance Conditions (Compliance component #3) — Imminent threat to public health and safety ❑ Other Compliance Conditions (Compliance component #3) — Failing to protect groundwater ❑ System not abandoned according to Minn. R. 7080.2500 (Compliance component #3) — Failing to protect groundwater ❑ Soil separation (Compliance component #5) — Failing to protect groundwater ❑ Operating permit/monitoring plan requirements (Compliance component #4) — Noncompliant - local ordinance applies Comments or recommendations The second 1000 gallon septic tank, and 1000 gallon pump tank were camera inspected and found to have cracks on side walls and ceiling. The ls'tank is showing corrosion and sidewall deterioration. The septic tanks are orginal when the house was built as drainfield was re -done in 2001. The Septic Tanks will need to be replaced. City permit will be required. Pump tanks every 3 years The outside powers source for the pump in the pump tank will need to have the wires re -done inside the power source box as the wires are tied on the outside of a gang box. These wires need to be inside the ga"3 box. Certification i hereby certify that all the necessary information has been gathered to determine the compliance status of this system. No determination of future system performance has been nor can be made due to unknown conditions during system construction, possible abuse of the system, inadequate maintenance, or future water usage. By typing my name below, I certify the above statements to be true and correct, to the best of my knowledge, and that this information can be used for the purpose of processing this form Business name: Chip s Septic rvices Inspector signature Certification number: 4761 �_ - License number: 2064 (This document ias been electronically signed) Phone: 952-200-3176 Necessary or locally required supporting documentation si i �� ,�� d" ® Soil observation logs ❑ System/As-Built ❑ Locally required forms ❑ Tank Integrity Assessment 9 Y El Operating Permit ❑ Other information (list): https://www.pca.state.mn.us 651-296-6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-ww1sts4-31b • 412812021 Page 1 of 4 Property Address: 2600 'Rainey Roa¢ Orono MBusiness Name: Chip's Septilc Services N 1. Impact on public health — Compliance component #1 of 5 criteria: � System discharges sewage tothe OYes, El No ground surface System discharges sewage to drain O»m, No -tile, orsurface waters. _-_ System causes backup into O,es, No dwelling or establish-ment. Any'lms',answerabnve/nOitsmsU,esysten is an 'nlrninemt throwir) T�ublic hoa/li; a?���ty.__ Describe verification methods and results: Visual. Ran pump to determine hydrolic loading of system, Date: 9/23/2O25 - - Attached supporting documentation: El Other: Ej Not applicable 2. Tank integrity — Compliance component #2 of 5 Compliance System consists ofa seepage ph. OYos� El No meoopoo|, d�*e|, leaching pit. �- - —- oxother pit? Sewage tank(s) leak below their EJ Yes, El No designed operating depth? � vYe« which sewage tank(s)leeko: A n�V')xes"ens�er��ome/n��a�eo&heSysiem Attached supporting documentation: NEmpty tank(u)viewed byinspector Name o/maintenance business: Sewer Services License number ofmaintenance business: 2502 _ Date ofmaintenance: 9/23/2025 0 Existing tank integrity assessment (Attach) - Date ofmaintenance (mmmmvvy)� (n��v�ho��hi�'���e- ' years) (See form instructions mensure assessment complies with Minn R. 70820700xub». 4B(1)) LJTank ioNoncompliant (pumping not necessary - explain below) _ _ _ Ljumec beIequ�od oeoohbeveh�oaUunmo�hods and results:��- - -- - Tanks were pumped and camera inspected egthe time o/inspection, The second 1UU0gallon septic Xonh and ||»» pump mnxwo�cama�innpe�edand found tohave �adkoonside waUoand uei|ing The 1nt tankisuh'go showing corrosion and "i"""m.vv`enunaoun. The oepUutanks will need tubereplaced, City permit w|U'erequired. Pump tanks every "years mtp,://°w=.wo.state. m"u` ^ 651'296-6300 ^ u000s�auov o ���wuu+azu ^wzu�uz ~~` ^ ��~'n�w�d�uvse�/ce ^ xm//am*."a/,m�*/"e�"na,, Page 2ny4 Property Address: 2690 Rainey Road, Orono MN Business Name: Chip's Septic Services Date: 9/23/2025 3. Other compliance conditions — Compliance component #3 of 5 3a. Maintenance hole covers appear to be structurally unsound (damaged, cracked, etc.), or unsecured? ❑ Yes' ® No ❑ Unknown 3b. Other issues (electrical hazards, etc.) to immediately and adversely impact public health or safety? ® Yes- ❑ No ❑ Unknown `Yes to 3a of 3b - yscaEti is �;r. ,�37;7'7fY Ftd throat to }public h, abi b 3c. System is non -protective of ground water for other conditions as determined by inspector? ❑ Yes' ® No 3d. System not abandoned in accordance with Minn. R. 7080.2500? ❑ Yes ® No 'Yes "O .SC Or 3(1 - sysiej° i is fl,,iliol f to jJrotect f,Prowii wal-01 Describe verification methods and results: The outside powers source for the pump in the pump tank will need to have the wires re -done inside the power source box as the wires are tied on the outside of a gang box. These wires need to be inside the gang box. This will need to be corrected by an electrician Attached supporting documentation: ❑ Not applicable ❑ 4. Operating permit and nitrogen BMP* — Compliance component #4 of 5 ® Not applicable Is the system operated under an Operating Permit? ❑ Yes ❑ No If "yes", A below is required Is the system required to employ a Nitrogen BMP specified in the system design? ❑ Yes ❑ No If "yes", B below is required BMP = Best Management Practice(s) specified in the system design If the answer to both questions is "no", this section does not need to be completed. Compliance criteria: a. Have the operating permit requirements been met? ❑ Yes [:]No b. Is the required nitrogen BMP in place and properly functioning? ❑ Yes ❑ No Any x Describe verification methods and results: Attached supporting documentation: ❑ Operating permit (Attach) ❑ https://www.pca.state.mn.us 651.296-6300 800-657-3864 Use your "preferred relay service Available in alternative formats wq-wwists4-31b • 412812021 Page 3 of 4 Property Address: 2690 Rainey Road, Orono MN Business Name. Chigs Septic Services Date: 9/23/2025 S. Soil separation — Compliance component #5 of 5 Date of installation 8/8/2001 ❑ Unknown .... _.. _....... ..... ...... (mm/dd/yyyy) Shoreland/WelIhead protection/Food ® Yes ❑ No beverage lodging? Compliance criteria (select one): 5a. For systems built prior to April 1, 1996, and ❑ Yes ❑ No' not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Drainfield has at least a two -foot vertical separation distance from periodically saturated soil or bedrock. 5b.Non-performance systems built ' ® Yes ❑ No' April 1, 1996, or later or for non- performance systems located in Shore/and or Wellhead Protection Areas or serving a food, beverage, or lodging establishment: Drainfield has a three-foot vertical separation distance from periodically saturated soil or bedrock.' 5c. °Experimental'. "Other", or "Performance" ElYes ❑ No - systems built under pre-2008 Rules: Type IV or V systems built under 2008 Rules 7080. 2350 or 7080.2400 (intermediate Inspector License required <_ 2,500 gallons per day; Advanced Inspector License required > 2,500 gallons per day) Drainfield meets the designed vertical separation distance from periodically saturated soil or bedrock. ;Any no" answer above ..-( lCcr .,. ito svtevrl is failing to protect Attached supporting documentation: ❑ Soil observation logs completed for the report ® Two previous verifications of required vertical separation ❑ Not applicable (No soil treatment area) ❑ The drainfield was update_ in 2001 10" it C�_ 1019 T3� It Z(p C L_ 101 A °fly Indicate depths or elevations A Bottom of distribution media 12 plus in SAND B. Periodically saturated soil/bedrock 26 inches C. System separation >30 inches D. Required compliance separation' 31 inches `May be reduced up to 15 percent if allowed by Local Ordinance. Describe verification methods and results: Used soil probe and tile probe to determine depth of system and soils on site Upgrade requirements: (Minn. Stat. § 115.55) An imminent threat to public health and safety (iTPHS) must be upgraded, replaced. or its use discontinued within ten months of receipt of this notice or within a shorter period if required by local ordinance. If the System is failing to protect ground water, the system must be upgraded, replaced, or its use discontinued within the time required by local ordinance. If an existing system is not failing as defined in law, and has at least two feet of design soil separation, then the system need not be upgraded, repaired, replaced, or its use discontinued, notwithstanding any local ordinance that is more strict. This provision does not apply to systems in shoreland areas, Wellhead Protection Areas, or those used in connection with food. beverage, and lodging establishments as defined in law. https://www.pca.state.mn.us 651-296.6300 800-657-3864 Use your preferred relay service Available in alternative formats wq-wwis1s4-31b • 412812021 Page 4 of 4 Minnesota Pollution Control Agency 520 Lafayette Road North St, Paul, MN 55155-4194 Compliance Inspection Form Existing Subsurface Sewage Treatment Systems (SSTS) a,1� . Parcel number: System status: (based on all corm Summary Fc Property Infc Property owner Property addres Property owner' w .... %„ ,,,, ,, ,,,,, Instructions on page County: 11-Mittli P party owner phone: `��.�``lt%j-7S)`i permitting authorlty: C j Date system conns� Reason for Inspection; System Description Brief system description: Local permit number: IN Design flow rate _6700 Is the system: f In Shoreland area? ❑ Yes KNo In Wellhead Protection Area? ❑ Yes %� No An U.S. Environmental Protection System serving a Minnesota Department " �f Agency (EPA) Class V Injection Well? ❑ Yes KNo of Heath (MOH) licensed facility? 0 Yes X No Compliance StatUS (Based on state requirements —additional local requirements may also apply.) Based on the information gathered and reported on attached forms, the compliance status of this system is (cneck once KCertificate of Compliance — valid until (3 years from date of report): ❑ Notice of Noncompliance - For Noncompliant systems: The reason for noncompliance is: This noncompliant system Is classified as (check one below): Q Imminent threat to public health & safety ❑ Failing to proteot groundwater ❑ Not in compliance wilh operating perm,,. Certification (Completed form must be submitted to the local unit of government within 15 days.) i hereby certify that all the necessary information has been gathered to determine the compliance status of this system; r, determination of future system performance has been nor can be made due to unknown conditions during system consvoci. �10 possible abuse of the system Inedequ to maintenance, or future water usage. Name: _. CL ,y Ltror- k� MA Certtficatton number: 6R Business license name and number: j,-A %cj Sgysfi" 5. or Name of local Signature: Required Inspector Complete: This Inspection Report is 5�_ pages long. Check complf forms attached: i�lydrauUc Performance 04ank integrity (Ksao Separation p Operating Permit Form w applicable) tarn drawing/As-built dra ng ❑ An assessment of any local requirements that are different from what .9 reou,reo on iris torn © S Boring Logs M Abandonment form (it appropriate) 0 Other Information (fist): Upgra a Requirements (derived ft m Minh, Slat. §415.55) An intminenf threat io public health and sarary (17P)1S) rrwsi be upgraceo. renaa: ac : Ifs use d/s00r111nl/ed wfwn ten months of reCalpt or iNS nowke of within a stlonar period irrequired by Idca1 ordinance. if the system 4s taibng to protect water. IN syslom must Se uppreded, replaced, or Its it" diseonfinued within the firne required by)oeat ordinance. It sit existing sys,em is not tan,i:s as re;'�r: law, and ties al laaSI two feet or design sod separaboe, than the system head not be upgndad, rapaimd, replaced, Wits use discont,nueo. nor,�,;ns•. s: -:; s�. tocar ordinance inat+s mom stn'ct. This provision does not appry 10 systams in Shoreland areas, Wallhead PlateCt on Areas, or rnose useo m ;once boverege. and todginp establishments as dented in law, wq•wwisrs4.31 Compliance Inspection Form for E+i5:rng SSTS 411108 SO/TO 39a8 ZTTEELSZ96 6Z:b1 TTOZ/90/90 Parcel number: System status; Compliant ❑ Noncompliant (as determinedZY, t is form) Soil Separation Compliance and Other Compliance Compliance Issue #3 of_4 Date of observation: Q-54— Reason for observation: This information on this form does not expire, Compliance questionslcriterla: (Required) For systems built prior to April 1, 1996. and not located in Shoreland or Wellhead Protection Area or not serving a food, beverage or lodging establishment: Does the system have at least a two -foot vertical separation distance from periodically For non-performance systems built April 1 — 1996, or later or for non-performance systems located In Shoreland or Wellhead Protection Areas or serving a food, beverage or lodging establishment: Does the system have a three-foot vertical separation distance from periodically saturated For reduced separation distance systems (i.e., "performance" systems under old 7080.0179 or Type IV or V system under new 7080. 2350 or 7080.2400): Does the system meet the designed vertical separation distance from periodically saturated Any "na" answer Indicates that the system Is failing to protect ,ground water. Certification Verification Method"*: (Optional) (Check the appropriate box) Conducted soil observation(s) (attach boring logs) ❑ Two previous verifications (attach boring logs) Cl Other: k 1 i 9 a. I- QA )o�_�s Soil observation does not expire, Previous observations by two independent parties are sufficient, unless site conditions have been altered. May be reduced by up to 15 percent if allowed in local ordinance, No standard protocol exists. This list is not exhaustive, in sequential order, nor does it indicate which combinations are necessary to make this delerminetion. This form Is to be completed and attached to the Summary Form of the Minnesota Pollution Control Agency's (MPCA) Compliance Inspection Form for Existing Subsurface sewage Treatment Systems. Observations, Interpretations, and conclusions must be completed by an inspector or designer. Completed rm must be submitted to the local unit of government within 15 days. Property owner neme(s); Property address: Property owner's address (it different): — County: Phone: _ ----.. •--• ..._ ... i hereby certify That I personalty made the observations, Interpretations, and conclusions reported on this form and that they are correct. Name: ­14t 11 `` Business license name and number Name of local unit of 3M t: Signature: wq-wwisrs4.31 411108 90/00 3917d Certification number or Date: Compifance Inspection Form for Existing SSTS ZTTEELGZS6 GZ:bT TTOZ/90/90 Swedlund Septic Services, Inc. 25648 - 2001 Street • Belle Plains, MN 56011 952-873-3292 Josh I Swedlund Lic. #2502 Date: 90/90 3Jdd ZTTEELOZ96 6Z:01 TTOZ/90/90 T 3 b T 3 S'6 q3'b �G D �Je l l Lq 6'3 37 �6