My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1985-05-20 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
D
>
Dickey Lake Drive
>
770 Dickey Lake Drive - 27-118-23-33-0010
>
Septic
>
1985-05-20 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2025 1:57:53 PM
Creation date
9/24/2025 10:24:52 AM
Metadata
Fields
Template:
x Address Old
House Number
770
Street Name
Dickey Lake
Street Type
Drive
Address
770 Dickey Lake Drive
PIN
2711823330010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM DESIGN <br />FOR GARY RODERICK <br />LOT 7, BLOCK 1, RINGERSWOOD <br />ORONO, MINNESOTA <br />5-20-85 <br />1. Percolation Rate, Ty,<, J System. <br />Percolation tests were. taken previously by others. ltwever, the proposed <br />house is on the primary si-Lie' tested earlier. Thus, we took new percolation <br />tests for a primary site and had an average percolation rate of 25.2 M.P.I. <br />but a high water table re:uiring a mound system. Tests were done at an 18" <br />depth because these upper layers would be used for the proposed mound <br />syste. The old alternate site should still be preserved for possible future <br />use. <br />2. Proposed Flow Rate. <br />4 bedrooms @ 150 G.P.D. is 600 G.P.D. <br />3. Soil Treatment Area Needed. <br />600 G.P.D. x 0.83 factor is 500 Sq. Ft. of rock bed area. or a bed 10 feet <br />wide by 50 feet long. <br />4. Septic Tanks and Distribution System. <br />Two septic tanks of 1000 gallons each are recommended. In addition, a third <br />pumping tank will be seeded to house the pump required for pressure dis- <br />tribution to the mound area. Distribution to the rock bed is to be through <br />3 perforated laterals 40" apart. All construction and materials should <br />adhere to the provisions of the city o' Orono. <br />5. Mound Dimensions. <br />(Ise a 2.67 factor x 10 feet of rock bed width or 26.7 feet for the basal <br />width. Since the ground slope is between 1.5 to 2.5 %, both the upslope and <br />downs!ope areas can be used. % wever, with a 3 foot high mound and 4:1 <br />sideslopes, the total width would oe 10 feet for the bed plus 11 fcet <br />upslope and 13 feet downslope or 34 feet which should be used rather than <br />the 26.7 feet. <br />If there are any other questions, please contact me. <br />Sincerely, <br />PERCOR, INC. <br />Mark S. Gronberg, P.E. <br />
The URL can be used to link to this page
Your browser does not support the video tag.