HomeMy WebLinkAbout1988-08-04 On Site Sewage Treatment Inspection ReportOff the North .Shore of*
ON -SITE SEWAGE TREATMENT CITY
Lake Minnetonka
INSPECTION REPORT OF POST OFFICE BOX 66
. O O 1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER Da"^tj `I Da►"ittriSt %(r- L ADDRESS 7,?-5 Dteke`l LLtKF by"' -
PERMIT NO.'S. - , 54 f -- DATES - lk'-2S -86 - CONTRACTORS C ID✓r-r ii i I Ce
City Ordinance tic 210 requires that each on-tite sewage treatment system in Orono be ,,iuwted on a regular basis. The o.isite sewage
treatment system at the above
address has been inspected► and apr s to fall into the category checked below.
(This;; P/an existing system ❑ new construct inn)
1 Meets or exceeds current City standards in all re"cts relating to design, construction, and location. Appears to be operating
properly.
2 Does not meet all current City standards for new construction 114-8 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be tunctioning prope.rly, no male
upgrading of the system is required at this time.
3 Does not meet current Cite standards in many respects relating to design, construction, or location. Appears to oe operating
adequately at this time, tsu; has a relativety high potential for future problems. No major upgrading of system is required at
this time.
D4 System may or may not meet current City standatrs for design, construction or location, but is failing to p+ojsedv treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or gtoun Waters. or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system tepair/
replacement procedures If drainfield replacement is necessary, soil testing wil! usually be (equued, and a design and site plan
must be submitted for •t ew. Your cer.tractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items n ay require your action)
Tank :pection indicates
V umpout not needed at this time.
d ;;nfids accumulation in tanks indicates they should be pump-
ed out this year to help prevent future problems.
❑ &dids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
iystem is discharging to surface. Tanks must be pumped
within 48 hot, - • -) eliminate surface discharge.
Inspection risers missing —'inks could not be inspected.
It ;peciion risers 14" dia. pipe) must be installed in each tank
at next pumpout. If tanks have not been pumped out within
the last three years, they should be pumped out now.
SITE CHARACTERISTICS
Lin sting Site Factu•s
❑ elope
'V'So r I
❑ High wafer table
❑ Lot size
❑l Lake, wetland, or stream
]!z Dtamage
COMMENTS:* see a Hattie
G Inspection pipe is located directly over tank beffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped •ut within the last three years, they
should be pumped out now.
Drain eld inspection indicates
Dramheld is dry, no surfacing evident.
Some evidence of surfacing, not critical yet.
❑ Drainfield is saturated and vts,bly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to draintield Contact the City Inspector
immediately. Repair! mu. be completed within 90 days.
❑ Drainfielu exv!nt and condition t;nknown.
Potential for _iystain Failure
!depends on sod types, water
table pod system condition)
Low
❑ Medium
❑ High
❑ System is causing visible
surface discharge.
Site Capabilities for
Fuiur Expansion
Adequate
❑ Fair
❑ Poor
11 Inadequate
Divi of Insreetron ~ Septic System It for
Note I.• the event ghat this inspection report is used to satisfy the requirements for a mortgage or other transfer of property• be i4vtsed d• .
this report does not guarantee or certify that an existing tystem will continue to function properly, but is merely at opinion of the ado ;uscv
of the system un(1cr cut tent - •inditions biased on the available information
This report must be kept %n the pretruses with system location and pum•sing records
WHITE COPY / Inspector's File GOLD CW Y ' Homeowner