HomeMy WebLinkAbout1980-11-25 Septic System Design ReportCITY OF ORONO E Cory SEPTIC SYSTEM DESIGN F�� r K APPROVED APPROVED WITH CORRECTIONS DISAPPROVED Address Ln.f J0, / LAA . Z3i�' ��t//.�-� Z-4,t jFy, Builder/Contractor P-eDrieZ n 1ktnC% Comments: f /-2-S"-130 Date Septic Sy m Inspector flTTV nr nnn"^ PROTECT DRAINFIELD AREA DESIGNATED DRAINFIELD SITES SHALL BE STA. KED OFF PRIOR TO CONSTRUCTIOtV OR EXCAVA- TION IN THE AREA. THE ORAINFI ELO AREA SNALi:. REMAIN UNDISTRUFEU L!N7IL DRA!Nd iEI_D CON- STRUCTION IS CG,�%,N�9E•'�;CE7. NO VE'-''^ULAR TRAFFIC 09 S T 0Ci'PILIN'i; " ALLO!'JtD WITHIN CESiC,,: d' FILL S! IALL eE '` �'U DnAINIFiELD AI?cA EITHER BEFORE OR AFTER D,RAINIFIELD INSTAL_ LATION. VIOLATION MAY REQUIRE OF THE SOIL KEEP OFF DRAINFIELD ARE: t; ,7s . Uj DF-v/ N x ,so. ,4! 1 40 ' 1 O N � e 0 O �'0 3 S (q LANE je isz.4 470 O x /St. 4 , / 5/• G �1111- 11 1 4a x ass a ot.e �e do. 1 sir` ►'q�'Z . 1 1 , rISZ. 9 � 155, l x /54••3 W47.7 { �r 9.M, iso, oO NW Cor. 7o��r Bose I � O v z l5�• 5 x /Sl.S Iq4 N X 1S/.9 1 390 0o N. B9'4-¢'41 E. Proposed Top of Foundation Elevation = 158.0 Proposed Garage Floor Elevation = 157.5 Proposed Lowest Floor Elevation = 150.0 I hereby certify that this is a true and correct representation of a survey of the boundaries of: Lot 10, Bloch 1, THE NURSERY, Hennepin County, Minnesota. And of the location of all buildings, if any, thereon, and all visible encroachments, if any, from or on said land. As surveyed by me this 11th day of November, 1980. Thomcs S. Bergquist Land Surveyor, Minn. Reg. 7725 1 SCALE { FO Prepared for: SATHRE-BERGOUIST, INC. EwA AC 2�64 REGFIELU HC'ES E]lIA.TWAfIATAaV% • WAIZArA MN »3,1 IIEh_ TI\IP10040 61. ATL Clfi%r• n SITE YVALUATION REPORT FOR REDFI-MD HOM 3S 7S "�`�'�►�- LOT 10, THS NURSERY 9-10-80 On September 6, 1980 six percolation holes Were tested and three soil borings taken, the primary site was comprised of holes 1-4 Which were located -west of the proposed house. Holes 5 and 6 were in the al- ternate site on the south side if the lot. All the percolation holes were dug 6 inches in diameter to a 42 inch depth while the soil bor- ings were dug 6 inches in diameter to the 4 foot depth and 3 inches In diameter to the remaining depth. All holes were dug with bucket type band augers, Water was kept in the holes the night prior to testing after which the holes were tested in �j hour intervals for 4-.-hours. The av- erage percolation rate for the primary site was 16.6 minutes per inch. which would be acceptable for a standard drainfield system. However, with a high water table in wet seasons possible in this area, the trenches should be kept fairly shallow. Very good material was en- countered on the alternate site which could aeowt a standard system a2ss. Beeausse-the primary site should be no nearer than 75 feet to the small low area to the weet., and iha elevation drop it about 7 feet from the top of the hill to the drainfield area, the hovsw might have to be rafaUd slightly to obtain a walkout to the. drainfield sftbe-this area (dsainfteld 21#4 can not be graded. Additional design information follows. Lf any questions arise or other information is needed, please contact me. sincerely, ?3RCOR, INC. A1 Mark 3, Gronberg, P.B. i • R sDFI3LD HOMES LOT 10, TH3 NIIRSEW Percolation Results Hole No. Material P-1 Brown Clay Loam P-2 Brown Loam P-3 Brown Silty Loam P-4 Brown Silty Loam P-5 Brown Gravelly Loam P-6 Brown Gravelly Loan Percolation Rats_ 20.0 Min./inoh 12.0 16.0 18.5 7.7 20.0 The average percolation rate for holes 1-4 is 16.6 Min./inch. s..oll Bo r,Inx& d� H� Devth(ft. ) Material 0.0-0.5 Dark Brown Clay Loam 0.5-4.0 Brown Clay Loan 5.0-8.0 Gray Brown Silty Loam Mottled soil at 1.11 feet and no wateiti table alter 24 hours. wnth(ft. ) 0.0-3.6 3.8-4.2 4.. 2-4.6 4.8-8.0 Uteri Brown Clay Loan Brown Silty Loam Brown Salty Loan Gray Brown Clay Loam Mottled soil at 5.3 feet and no water table after 24 hours. S.B. Dewtb_ Materill 0.0-0.7 Black Loan 0.7-1.2 Brown Loan 1.2-2.0 Coarse Sandy Clay Loan 2.0-3.0 Coarse Sandy Lem 3.0-4.0 Gravelly Loam 4..-6.5 Medium sand 6.5-8.0 Sandy Loam NO mottled soil or water table after 24 hours. Iv O t � !tic h �b V 1 l .o! , sss - V-01 SYST-�Y, DRSIGN 1. Percolation Rate, Type, of System 16.6 minutes per inch. Standard system with trenches no deeper than 2-2,5 feet, 2. Proposed Flow Rate 4 bedroom house = 600 gallons per day(GPD), 3- Soil Treatment Area Required For a percolation rate from 16-30 NPI a factor of 1.67 times the flow rate a 1000 sg.ft, of area is required. !�. 31" juA Humber of Trenohes Five trenches 2 feet wide and 100 feet long would yield 1000 sq.ft. Two foot wide trenches should be spaced 6.5 feet minimwe venter to center. 5. Filter Needed 55.6 cub+, yards of rook is needed for 1000 sq.ft, of drainfield with 12 1es or rock below and 2 inehes over a 4 inch pipe. 6. septic Ys Two 1000 gallon septic tanks are recommended, -4 iD ' D o --i o A 01� I On r ir- 0 o e o 0 0 0 0 0 z (n Mr �N o 3 Om -U�N p - �N z x 4 *U�rrn .D X o z O c mmN mo= op <p F m �'.' r- fm m-n z ;u-i>o mmon woromo mzozr� -mru1 ommr rm mp I arm > Ozz<� -n m rna-i n<o z--1 m=x mmmo-{CD o0o Oc m�rm mjmDo io 3 0 gzn'-� pD �_- �DOmiz zoz o m ml �n0Nm =�0O mp.0vpi -� m m;ao0 O nx tam _-D X. �- �-q&0 m --i Wz; oioD m r�io - ' p�r=r1o^� -n_ mmoi Oz = i —C v►mz K mmFo pXm3 ivaooz r�r�rn M-D LO -i CD mN-0z DZKu'D-u Dorn m -urn Do nDo�xU� NO *� r- ncn nD�p ZZTNmm Gip� nrnm _ m �c Fm mmmom M:A � 7pD�r nv r0 N m z oN :W N zm rn m 0z 0 r O 'D om u CD oz xm x ME! O_ �D mK rrn r ..i �m =2 n `n DM .D m n 0 z C� c 'A f -0