HomeMy WebLinkAbout1987-08-24 On Site Sewage Treatment Inspection ReportON -SITE SEWAGE TRcATMENT INSPECTION REPORT OWNER TOOrn K 4w � PERMIT NO.'S. -- DATES _ 10 - >� —�q —.— CONTRACTORS �f11_( llr�Q r-)_—_ City Ordinance No 210 requires that each on -site sewage treatment system in Orono ne inspected on a egular basis. The on -site sewage treatment system at th, above edriress has beer inspected and appears to fa I into the category checked below. (This is V an existing system ❑ new construction) b1 Meets or exceeds current City standards in all respects relating to design, construction, and location. Appears to be operating Wl properly. 2 Does not meet all curre,it City standards for new construction 11978 Code) but in mos; respects appears to be designed, located, and constructed generally in accordance with previous coues. System appears to be functioning properly; no major upgrading of the system is required at this time. 3 Does not meet current City standards in many respects relating to design cor,-•ruction, or location. Appears to the operating adequately at this time, but has a relative y hig'� potential for future problems. No major upgrading of system is required at this time. 4 System may or may not meet current C.r, standards for design, construction ^r location, but is fadrny to properly treat and dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or groundv aters, of is cr,tating a safety hazard, or is otherwise creating a public nuisance. Plea:e contact the City Inspector to discuss sys:em repair/ replacement procedures. If dramheld replacement is necessary, sod testing will usually be required, and a d^sign and site plan must be submitted for review. Your contractor must obtain a permit before work is started. On the Nortb Sbore of Lake Minnetonka POST OFFICE BOX 66 1335 S. Brown Rd. Crystal Bay, MN 55323 473-7357 SYSTEM CONDITION ( [0 Checked stems may require your action) Tank inspection indicates ❑ Pumpout not needed at this time. ❑ Solids accumulation in tanks indicates they should be pump - ad out this year to help prevent future problems. ❑ Solids accumulation in tanks is at a critical level. Tanks should be pumped out as soon as possible. ❑ .System is discharging to surface. Tanks must be pumped within 48 hours to eliminate surface discharge. ❑ Inspection risers missing -tanks could not be inspected. Inspection risers (4" d pipe) must be installed in each tank at next pumpout. If tanks have not been pumped out within the last these years, they should be pumped out now. SITE C14ARACTERISTICS Limiting Site Factors ❑ Slope ❑ Soil ❑ High water table ❑ Lot sire ❑ Lake, wetland, or stream ❑ Drainage ADDRESS rL320 I�c�tai 21 � t^,� Inspection pipe is located directly over tank baffle. (Does not give accurate measurement of solids accumulation.) If tanks have not been pumped out within the last threeyeNt. tMy, should be un! a out now— Drainfield - _ Urainfield inspection indicates - - N Drainfield is dry, no surfacing evident. ❑ Some evidence of surfacing, not critical yet. ❑ Drainfield is saturated and visibly discharging untreated effluent to the surface. This condition may require replace ment or additions to dramheld. Contact the City Inspector immediately. Repairs must be completed within 90 days. ❑ Drainfield extert and condition unknown. Potential fcr System Failure Site Capabdstiex for (depends on sod types, water Future E xpansion table, and system condition) 51 Adequate FLovv 7 Fair Medium ❑ Poor ❑ High ❑ Inadequate ❑ System is causing visible surface discharge. - pate of Inspection - --- -- Septic Syst or Note In the event that Mis itllOKtlpil. teuort JL 11d to satisfy the requirement for am - trcn1er_pf 2!9j! y, be adeifM that this r 1_dt�sef nOt gt.rtee or certify that an existing system will cOnhnW ,Uftct on properly, but is tMtNy an opinion oTtTsa lacy-- of� ft system under current a pions based 6-n eviitMa trtfornsufth. — - - _ - --- - This report must be kept on the pretnhp with system location and pimping records. WHITE COPY f Inspector's File GOLD Cr`.- I / Homeowner