1981-05-11 Septic System Design Report
Orono
>
Property Files
>
Street Address
>
D
>
Devin Lane
>
2225 Devin Lane - 03-117-23-21-0012
>
Septic
>
1981-05-11 Septic System Design Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2025 3:58:27 PM
Creation date
8/27/2025 3:54:18 PM
Metadata
Fields
Template:
x Address Old
House Number
2225
Street Name
Devin
Street Type
Lane
Address
2225 Devin Lane
PIN
0311723210012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORONO COPY <br />SIT'; -,Vls,UAT10.; <br />IOT 7, BLOCK 1 <br />`TH 3 111JR i Hy <br />5-11-81 <br />/0(7 (eW S` <br />` c / <br />On 1-:ay 6-7, 1981 tine above lot was tested for the suitabil- <br />ity of supporting an on -site sewage drainfield system. Four per- <br />colation holes were tested and two soil borings taken in the pri- <br />mary site while two percolation holes and one soil boring were ta- <br />ken in the alter•nat© site area. In addition, one :;oil borin was <br />taken in the area of tho proposed house. <br />The percolation holes were dug 6-inches In diameter and 2 ft. <br />deop while the soil borings wer,; dug 6 inches in diameter to the <br />11. ft. depth and 3 inches in diameter to the remaining depth. All <br />holes were dug with bucket typo hand augers, <br />Because of the hiC1i water table in this aroa the percolation <br />holed wero tested at the shallower depth for a mound or shallow <br />trench system. Since the area contai-od an abundance of black <br />loam, the av :rs3e Percolation rate a rather fast 115.5 minutes <br />,Aii.ch would allow the she trench system to be con- <br />structed. <br />However, because of the high grater table in the area,it will <br />be necessary to construct an interceptor drain around the drain - <br />field area to divert runoff water. This could be part of the drain <br />tile system used t•ri.th the house. This drain should be 4 to 5 feet <br />do-,p �:tth rock bein; placed over the tile with some black dirt <br />i)laced on trio top to establi.sii a grass cover, <br />Additional oyster desi�-,n lnformat` on follows. If any other <br />information is no !deri, ploZro contact !.-p. <br />Sincerely, <br />.00 <br />Bari; <br />