Loading...
HomeMy WebLinkAbout3445 Crystal Bay Road - Building Plans: ResidentialE1E1 EXTERIOR ELEVATION FRONT E2E2 EXTERIOR ELEVATION LEFTE3E3EXTERIOR ELEVATION BACK E4E4 EXTERIOR ELEVATION RIGHTBEDROOM WIC ATTIC ATTIC ATTICATTIC (OPEN TO PRIMARY BEDROOM BELOW)DOWNSHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-1 7/27/2020 Third Floor Plan, Existing1/4=1'0" Reviewed for Code Compliance Nicole Post RPS24-000142 12-16-24 Approved plans must be on site for the duration of the project. Plans must be available to inspector. Please call 952-249-6000 to schedule all inspections. Have permit number and address when calling. Separate Permits Required Plumbing Mechanical Electrical W01W01 W02W02 W01W01 E1E1 EXTERIOR ELEVATION FRONT E2E2 EXTERIOR ELEVATION LEFTE4E4 EXTERIOR ELEVATION RIGHT12'-1"16'7'-5"4'7'-11"7'-5 1/16"15'-6" 12'-5"15'3'-11" BEDROOM WIC ATTIC ATTIC ATTICATTICDOWN ATTIC ATTIC OBSERVATION ROOM WOOD BURNING STOVE108"WET BAR REF.MOVE BACK RAILING MAINTAINING 6'8" HEADROOM ABOVE STAIRS APPROXIMATE 4'6" CEILING HT. AT WALL APPROXIMATE 4'6" CEILING HT. AT WALL 9'0" CEILING HT.FLOOR DROPS 6"108"DWACCESS PANEL ACCESS PANEL Third Floor Plan, Proposed1/4=1'0" SHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-2 7/27/2020 NEW WALLS E1E1 EXTERIOR ELEVATION FRONT E2E2 EXTERIOR ELEVATION LEFTE3E3EXTERIOR ELEVATION BACK E4E4 EXTERIOR ELEVATION RIGHTBEDROOM PRIMARY BEDROOM BEDROOM BEDROOM WIC UP(OPEN TO ABOVE) SHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-3 7/27/2020 Second Floor Plan, Existing1/4=1'0" Per engineer's response - block one side with 2x N E1E1 EXTERIOR ELEVATION FRONT E2E2 EXTERIOR ELEVATION LEFTE3E3EXTERIOR ELEVATION BACK E4E4 EXTERIOR ELEVATION RIGHT1:00 PM 10/3/2024 REF. LIVING ROOM DINING GARAGE KITCHEN MECH.UPPOINT LOAD POINT LOAD SHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-5 7/27/2020 Main Floor Plan, Proposed1/4=1'0" 2(9 1/2") LVL (2J/1K) per engineering response SHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-6 7/27/2020 Elevations, Comparison1/8=1'0" PROPOSED EXISTING WEST NORTH EAST OBSERVATION ROOM PRIMARY BEDROOM LIVING/DINING ROOMEXISTING PARALLEL CHORD TRUSSES (FIELD VERIFY)9'0"4'6"2X10 JOISTS @ 16" O.C. (ENGINEER TO VERIFY) SHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-7 7/27/2020 WINDOW SCHEDULE 3D EXTERIOR ELEVATION NUMBER LABEL QTY FLOOR SIZE DIMENSIONS DESCRIPTION W01 2058FX 2 3 2058FX 24"X68"FX FIXED GLASS W02 5068FX 1 3 5068FX 60"X80"FX FIXED GLASS-AT SHEET:PROJECT DESCRIPTION:DRAWINGS PROVIDED BY:SCALE:Orfield Drafting Services3507 W 50th St.Minneapolis, MN 55410(952)-454-2705, 3445 Crystal Bay RdWayzata, MN 55391, -DATE:SHEET TITLE:A-8 7/27/2020 TEMPERED WINDOWS Nicole, Please find the answers from the engineer to your questions below. I have also attached a copy of the plans with the engineer's stamp on it to this email. As well I have uploaded this set of plans to the web portal. Please let me know if there is anything else you need. Thanks, • - Provide a beam calc sheet for the W8 x 48 or provide engineering. What is the beam blocked solid with? Both sides or only one? 1. Stamp added to verify calcs. One side of the beam blocked with typical 2x lumber trimmed to fit. • - What is the size of the first floor window header carrying the point load from above? Is it able to support the load? Are you proposing 3(2x6) on either side? 2. B2: (2) 1 3/4" x 9 1/2" 1.8E LVLs [2J/1K] • - Provide existing window headers of gable end walls for the first and second floor. Are these headers able to support the new loads from the floor addition? 3. From what we are able to see - yes. I will field verify once demolition of the area is complete. Greg Roane Email: greg@barnwoodgroup.com Office: 952-303-4416 Cell: 651-278-8572 www.barnwoodgroup.com ____________ Barnwood Group, Inc. 6255 Bury Drive Eden Prairie, MN 55346