Laserfiche WebLink
ON SITE SEWAGE TREATMENT <br />INSPECTION REPORT <br />CITY <br />OF I <br />I ORONC^ <br />On the North Shore of <br />Lake Minnetonka <br />POST OFFICE box X>6 <br />1335 S. Brown Rd <br />Crystal Bay, MN 55323 <br />4737357 <br />OWNER ADDRESS SiO__ <br />PERMIT NO.'S.DATES CONTRACTORS <br />City Ordinjnet No. 210 raquiret that each on-«ite wvvage treatment syitem in Orono be inspected on a regular basis. The on-site sewage <br />treatment system at the above address has been inspected and appears to fall into the category checked below. <br />(This It fi4. Jn existing system □ new construction) <br />^ Meets or exceeds current City standards in all respects relatirsg to design, construction, and location. Appears to be operatiisg <br />properly. <br />r~l 2 Do** oot meet ell current City standards for new construction (1978 Code) but in most respects appears to be designed, <br />located, artd constructed generally in accordance with previous codes. System appears to be functioning properly; no major <br />upgrading of the system is required at this time. <br />I I 2 Does not meet current City standards in many respects relatirtg to design, construction, or location. Appears to be operating <br />adequately at this time, but has a relatively high potential for future problems. No ma|or upgrading of system is required at <br />this time. <br />I I A System may or may not nteet current City standards for design, construction or location, but is failing to properly treat and <br />dispose of the curre.nt input, and is endar>gering a water supply, or is a source of pollution to surface or g-‘sundwaters, or is <br />creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/ <br />replacement procedures. If drainfield replacement is necessary, soil testirrg will usually be required, and a design and site plan <br />must be submitted for review Your contractor must obtain a permit before work is started. <br />SYSTEM CONDITION ( (Z Checked items may require your action) <br />T«tk inspection indicates: <br />□ Pumpout rtot needed at this time. <br />□ Solids accumulation in tanks indicates tf' -y should be pump­ <br />ed out this year to help prevent future pre 4ems. <br />□ Solids accumulation in tanks is at a t tical level. Tanks <br />should be pumped out as toon at pouible <br />D System it discharging to surface. Tank must be pumped <br />within 48 hours to eliminate surface ditch rge. <br />O Inspection risers missing-tanks could loi be inspected. <br />Inspection risers (4" dia. pipe) mutt be n stalled in each tank <br />at next pumpout. If tanks have not been pumped out within <br />the last three years, they should be pumped out now. <br />Inspection pipe is located directly over tank baffle. (Does not <br />give accurate measurement of solids accumulation.) If tanks <br />have not been pumped out within the last three years, they <br />snouid be pumped out now. <br />Drainfield Inspection indicates: <br />^^’Orainfield is dry. no surfaci>>g evident. <br />□ Some evidence of surfacing, not critical yet. <br />□ Drainfield is saturated and visibly discharging untreated <br />effluent to the surface. This condition may require replace­ <br />ment or additions to drainfield. Contact the City Inspector <br />immediately. Repairs must ba completed within 90 days. <br />D Drainfield extent and condition unknown. <br />SITE CHARACTERISTICS <br />Limitifsg Site Factors <br />□ Slope <br />□ Soil <br />□ High water table <br />□ Lot size <br />□ Lake, wetland, or stream <br />□ Drairtage <br />COMMENTS: <br />Potential lor System Failure <br />(depends on soil types, water <br />table, and system cortdition) <br />SSt Low <br />D Medium <br />n High <br />□ System is causing visible <br />surface discharge. <br />Site Capabilities for <br />Future Expamion <br />^Adequate <br />□ Fair <br />□ Poor <br />□ Irtadequate <br />Date of Inspection <br />rPJL/Ov <br />tic System Inspector <br />Note <br />this n <br />In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that <br />rt does not guarantee or certify that an existing system wilt continue to function properly, but is merely an opinion of the adequacy <br />of the system under current conditions based on the ave<lable information. <br />This report must be kept on the premises with system location and pumping record; <br />WHITE COPY ! Inspector 1 File GOLD COPY / Homeowner