HomeMy WebLinkAbout1981-08-10 Septic System Design ReportSIT; 'VALUATION R::PORT
FOR THOEAS BETZ
LOT 5, BLOCK 2
McCULL 'Y PAW,
8-10-81
On August 7-9s 19t••1 six percolation holes were tested and three
soil borings taken on the above property. The percolation holes were
dug 6 inches in diat:ot r and 2.5 feet deep to test for a shallow
trench system. The soil borings were dug 6 inches in diameter to the
it foot depth and 3 inches in diameter to the rensining cepth.The holes
Mere dug with both hand and power augers.
The primary site was located in the woods where some fairly per-
neable soil existed near the top and yielded a percolation rate fast
enough for a shallow trench system. The alternate site also could sup-
port a shallow trench system but the trenches should be no deeper than
6 inches because of the possibility of a high seasonal water table.
The primary site runs through some nice trees and it appears that the
larce ba:•swood will have to be removed but that the trenches can be
shifted enough to :piss the nice oaks in this area.
If the first floor elevation of tho house is about 14. feet above
the Ground on the small knob near the elm tree it should be possible
to use gravity distribution to the drainfield area. The trenches
shoal,.; be about ', irc: _:o:: doop near the house and about 18 inches deep
to the west since the ground is slightly higher there. Additional
system design information follo,rs. If any other quG3tions arise,
please contact re.
Sincerely,
PLRCOR,o Im.
w
i
Mark S. Gronbergs P.;.
Lot 5, Blook 2
McC11,T, .Y FARM
Poroolation Results
Hole No.
Material
Peroolation Ante
P-1
Black Loami
12.0 Min. /Incg
P-2
Gray Brn, Clay Loam
26.7
P-3
Black Clay Loam
26.7
P-4
Oray Brn. Clay Lown
17.1
P-y
Black Clay Loam
24.0
P-6
Black Clay Loam
30.V
The average percolation rate is 22.8 minutes per inch.
Soil Borings
Dep th(ft._) Material
0.0-1.0 Black Loam
1.0-1.5 Blaok Clay Loam
1.5-6.0 Gray Brn. play Loam
r. c
No eater table after 24 hours and►'mottled soil,
S B 2
Depthtft. ) t:ateriel
0.0-0.5 Black Loam
0.5-1.0 Black Clay Loam
1,0-6,0 Gray Brn, Clay loan
h"
`10 water table after 24 hours and"mottled soil.
Depth(ft, )
1aterial,
0.0-3.0
Black Clay Loam
3.0-4.0
Gray Brn, Clay Loam
4.0-6.0
Gray Clay
Vo water table after 2.4 hours and mottled soil at 3,5 feet.
LOT 5, BLOCK 2
EcCLUM ::Y FARM
System Design
1. Percolation rate. Tyne of System.
22.8 minutes per inch. Shallow Trench System.
2, Proposed Flow Hat
bedrooms C' 150 G.F.D. = 600 G.P.D.
3. Treatment Area Reguir^d, ,
Use 1200 sq. ft. of soil treatment area.
4. Size and Number of Trenches.
4 trenches 3 feet wide and 1 )0 feet long would = 1200 sq. ft.
5. Drainfleld Rock Reauirod,
14,4 cubic yards is needed for 6 inches under and 2 inches over a
4 inch distribution pine.
6. Se -)tic Tanks.
Two septic tan :s of at lanst 10)0 Gallon capacity are r3cor-ended
ui ti:i t. c c bove ,; s teri.
T
r m r;
A� II