HomeMy WebLinkAbout1988-05-18 On Site Sewage Treatment Inspection ReportON -SITE SEWAGE TREATMENT
INSPECTION REPORT
On tlie• .\urth .Short uf-
Lake- Mi ntrtonk.r
CITY
POST OFFICE BOX 66
1335 !z Brown Rd.
ORON 011ie, Crystrii - y, MN 55323
473-7:: _
OWNER D-4'V &000t�4fl ADDRESS �22F' 'k -7_,L_
PERMIT NO.'S. DATES 91T 7S S l'� CONTRACTORS atDlM 9 R'>^k
City Ordinance No. 210 requires that each on -site sewage treatment system in Orono be inspected m a regular basis. The on -site sewage
treatment system at the above addreu has been inspected and appears to fall into the category checked bel,zw.
(This is ❑ an existing system CI new construction)
�1 Meets or ids current City standard' m all respe is relating to design, construction, and location. Appears to be operating
properly,
2 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly, no major
upgrading of the system is required at this time.
D3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
4 System may or may not meet current City standards for design, construction or location, tiut is failing to properly treat and
dispose of the current input, and is endangering a water supply, or is a source of pollution to surface or grouudwaters, or is
creating a safety hazard, or is otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. If drainfreld replacement is necessary, sod testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Too i spection indicates:
VPumpout not needed at this time.
❑ Solids accumulation in tanks indicates they should be pump•
ed out this year to help prevent future problems.
❑ Solids accumulation in tanks is at a critical level. Tanks
should be pumped out as soon as possible.
❑ System is discharging to surface. Tanks must be -)umped
within 48 hours to eliminate surf; of discharge.
❑ Inspection risers missing -tanks could not be inspected.
Inspection risers 14" dia. pipe) m it be installed in each tank
at next purnpout. If tanks have i t beer,. numiped out within
the last three years, they should I, pumped out now.
❑ Inspection pipe is located directly over tank baffle. (Does not
give accurate measurement of solids accumulation.) If tanks
have not been pumped out within the last three years, they
should be pumped out now.
Drainfeld inspection indicates
WDrainfield is dry, no surfacing evident.
❑ Some evidence of surfacing, not critical yet.
L_) Dramlield is saturated and visibly discharging untreated
effluent to the surface. This condition may require replace-
ment or additions to drainheld. Contact the City Inspector
immediately. Repairs must be completed within 90 days.
❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS.
Limiting Site Factors Potential for System Failure $i� cities for
Cl Slope rrtepcnds on sod types, water tit xpensoon
❑ Soil table, nd system condition) Adequate
OHigh water table Low ❑ Fair
Lot size ❑ Medium ❑ Poor
❑ Lake, w-tland, or stream ❑ High 'Inadequate
❑ Drainage El System is causing visible
surface discharge.
COMMENTS
sew CY- VAe s «T s 1-WRI%ewTS
D to of Inspection Septic System Inspector
Note. In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of proper:,. oe advised that
this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
of the system under current conditions based on the available information
This report :nest be kept on the :)remises with system location and pumping records.
WHITE COPY Inspector's File GOLD COPY i Homeowner