HomeMy WebLinkAbout1990-07-30 On Site Sewage Treatment Inspection ReportON -SITE SEWAGE TREATMENT
INSPECTION REPORT
On the Nortb Sbore of
Lake Minnetonka
POST OFFICE BOX 66
1335 S. Brown Rd.
Crystal Bay, MN 55323
473-7357
OWNER A&A �' k ell ADDRESS
PERMIT NO.'S.�` S� TES J �'�-7� /'-Z�—_ CONTRACTORS '�' �' �/✓
City Ordinance No. 210 requires M ach on -site swage treatment system in Orono be inspected on a regular basis. The on -site sewage
traatment system at the above address hat n inspected and appears to fail into the category checked below.
(This is 61 an existing tam ❑ new construction)
S1 1 Meets or exceeds curt, . City standards in all respects relating to design, construction, and location. Appears to be operating
L7 properly.
192 Does not meet all current City standards for new construction (1978 Code) but in most respects appears to be designed,
located, and constructed generally in accordance with previous codes. System appears to be functioning properly, no major
upgrading of the system is required at this time.
❑ 3 Does not meet current City standards in many respects relating to design, construction, or location. Appears to be operating
adequately at this time, but has a relatively high potential for future problems. No major upgrading of system is required at
this time.
U4 System may or may not current City standards for design, construction or location, but is failing to properly treat and
dispose of the currenn , „o, end is endangering a water supply, or is a source of pollution to surface or groundwaters, or is
creating a safety hazard, -s otherwise creating a public nuisance. Please contact the City Inspector to discuss system repair/
replacement procedures. If dminfield replacement is necessary, soil testing will usually be required, and a design and site plan
must be submitted for review. Your contractor must obtain a permit before work is started.
SYSTEM CONDITION ( m Checked items may require your action)
Tank inspection indicates: 4- )iL. A Inspection pipe is lac ag s directly over tank baffle. IDoas not
❑ Pumpout not needed at this time. give accurate measurement of solids accumulation.) If tanks
❑ Solids accumulation in tanks indium they should be pump- have not been pumped out within the last three years, they
ed out this Veer to help prevent future problems. should be pumped out now.
❑ Solids accumulation in tanks is at a critical level, Tanks Drai field inspection indicates:
should be pumped out as Loon as possible. Drainfield is dry, no surfacing evident.
❑ System is discharging to surface. Tanks must be pumped ❑ Some widens of surfacing. not critical yet.
vvithin 48 hours to eliminate surface discharge. O Drainfield is saturated and visibly discharging untreated
❑ Inspection riars missing —tanks could not be inspected. effluent to the surface. This condition may require replace -
Inspection r'csers 114" die. pipe) must be installed in each tank merit or additions to drainfield. Contact the City Inspector
at next pumpout. If tanks have not been pumped out within immediately. Repairs must be completed within 90 days.
the last three Veers, they should be pumped out now. ❑ Drainfield extent and condition unknown.
SITE CHARACTERISTICS.
Limiting Site Factors Potential for System Failure
Site Capabilities for
❑ Slope (depends on soil types, water
Future Expansion
❑ Soil table, and system condition)
J-Adequste
❑ High water table f&Low
❑ Fair
❑ Lot site ❑ Medium
❑ Poor
❑ Lake, wetland, or stream ❑ High
❑ Inadequate
❑ Drainage ❑ System is causing visible
surface discharge
COMMENTS OIi Iy[ L�1�t' /!i%fC ��0� / . _ G�1� C�/ ✓r lit' / i/1 �n f�� iayC:1
d s S .
-A-4- rawkF �✓eer_ /cis 9- Z 7 0►i./ 51,a, Y I r jp,mp_/_��onn
,
Date of Inspection Septic System Inspector
Note. In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of property, be advised that
this report does not guarantee or certify that an existing system will continue to function properly, but is merely an opinion of the adequacy
of the system under current conditions based on the available information.
This report must be kept on the premises with system location and pumping recorris.
WHITE COPY / Inspector's File GOLD COPY / Homeowner