HomeMy WebLinkAbout1105 Brown Road South - Sewer Televising ReportTask # 96229
Date Called in
Date Scheduled 7/14/2025
City Of Orono
Point of Sale Sanitary Sewer Service I&I Compliance Inspection Form
Property Address: I 1105 Brown Road South
PID: 11011723240004
Owner Information
Name:
Nicole Middendorf
Mailing Address:
(if different from
-Property)
Phone:
- 5 Email: I Nicole @prosperwell.com
Inspector Information
Name:
Jimmy Nelson
Company/ Organization
City of Orono
Hi view Plumbing
License number:
Phone:
952-249-46861612-916-1685
Email:
Inspection
System
Standard
Pass
Fail
Roof Drains
Roof drains and leaders Roof drains should not be connected to the sanitary
sewer but should discharge to the ground outside of a building. If the roof
drains are connected to the sanitary sewer, disconnect them, plug any open
connections to the sanitay sewer using a non -shrink permanent material, and
redirect the roof drains onto the ground outside the building.
Foundation
Foundation drains are underground pipes that collect storm water from
`
Drains
around the base of a building and into a sump basket, where it is then
1!/
pumped outside of the building. Foundation drains should not be connected
to the sanitary sewer.
Sump pumps
Sump pumps arc designed to capture surface or ground water that enters
basements or crawl spaces and pump it away from the house. The basic sump
f /
system includes drain tile, a sump pit, a sump pump, a float or switch, and a
drain line. Sump pumps should not be connected to the sanitary sewer.
Sewer Service
Sanitary Sewer Inflow & Infiltration (1/1) Compliance Inspection Sanitary
Line
Sewer Lines. All sanitary sewer lines serving property, from the house to the
main line, shall be in a safe and functional condition and shall be free from all
leaks, failures including but not limited to partially collapsed sections or Iree
root intrusion. The sanitary sewer lines shall meet the City Code standards and
specifications. Details on back of this sheet)
Notes:
Mineral deposits at 113' and 125' that needs to be repaired.
Toilet Removed
o Yes o, No
For Inspection:
.Inspectors Signature:
Date:
Owners Signature:
Date:
CityReview
I I Compliant
I I I Corrective Action RSquired
Certificate of Compliance Expires:
Con•eclive Action Due by: 10/14/2025
Date: 7/16/2025
Signature,
Name: Heather Smieja
Service Line Inspection Details
Weather Conditions:
Approximate Depth of Service
Type and Size of Service
Overall Condition of Service Pipe
Please note all connections, fittings, points of concern on service line including infiltration, tree root,
cracks, misaligned joints, etc.
This report must include a digital copy of the televising.
Comment
Start for 4" cleanout in NE corner of Basement
z
Misaligned joint —Infiltration
J
1 L11
Notes: